• Title/Summary/Keyword: Active Arc

Search Result 131, Processing Time 0.024 seconds

Asymmetric Topography of Active Young Back-arc Basins and Tectonic Implications (활동적 배호상 해분의 비대칭적 지형과 그들의 구조적 해석)

  • Park, Chung-Hwa
    • Economic and Environmental Geology
    • /
    • v.30 no.6
    • /
    • pp.637-644
    • /
    • 1997
  • Active young back-arc basin such as Mariana, Havre, Lau, Manus, East Scotia basins have asymmetric topography of two types in respect to the spreading axis. The arc-trench wing of Mariana Trough, Lau basin and Havre Trough are shallower toward the active arc, whereas those Manus and East Scotia basins are nearly symmetric to the opposite wings. The other asymmetry which shows the spreading axis deviated from the geographic axis toward the active arc is observed in each basin. Active young back-arc basins show a large variety of asymmetry rates ranging from the lowest East Scotia Basin to the highest Mariana Trough. The asymmetric topography of these young back-arc basins seems to be caused by the rollback rate of downgoing slab under the basin. As the rollback rate increases, the asymmetry rate systematically decreases.

  • PDF

A Study on the Stabilized System Operation Considering the Reflection Characteristic of an Active-Phased Array Antenna (능동 위상 배열 안테나의 반사 특성을 고려한 안정적 시스템 운용에 관한 연구)

  • Kim, Young-Wan;Chae, Hee-Duck;Lee, Dong-Kook;Jeong, Myung-Deok;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • In this paper, a stabilizd system operation through a composition of a protective circuit and an improvement of active reflection coefficient(ARC) is studied. Unlike the passive-phased array antenna, the APPA is a combined form of radiating element and transmitter-reciever module. Therefore, a definition of new ARC that differentiates itself from typical passive-phased array antenna must apply. The ARC is a reflection coefficient considering a superposition of a coupling from nearby radiating elements and self reflection. It is an important parameter that predicts and analyzes charateristics of a APPR system. A high level ARC is a direct source inducing a performance degradation of a system. In this paper, as a method for a stabilized operation of APAR, one method for improving a performance and another for degradation prevention are analyzed. An effectiveness of two methods was validated using experiment results of real-fabricated active-phased array antenna.

ARC availability experiment by comparing plasma renin activity (PRA) and active renin concentration (ARC) (Plasma renin activity(PRA) and Active renin concentration(ARC)비교를 통한 ARC 유용성 실험)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.84-89
    • /
    • 2018
  • Purpose Renin is a proteolytic enzyme synthesized and secreted from epidermal(juxtaglomerular) cells in kidney. Renin acts on the renin substrate angiotensinogen to produce angiotensin I, and then angiotensin II is produced by the action of angiotensin converting enzyme. This causes the adrenal glands to boost blood pressure (vasoconstriction) and promote aldosterone secretion. While Plasma renin activity (PRA) is to test angiotensin I, the active renin concentration (ARC) is a renin test directly. They have different test methods and their own substrates. However, these two methods are sometimes interpreted as the same as a result. The purpose of this study was to evaluate the usefulness of the ARC test by comparing the results between PRA and ARC. Materials and Methods For the diversity of the experiment, 26 samples were requested to test with PRA(TFB company) and ARC(Cisbio company) to other institution. We compared and analyzed PRA(Immunotech company) and ARC(Cisbio company) tests using 28 samples from September $15^{th}$ to October $13^{th}$ in 2017. The statistical analysis method for PRA/ARC evaluated the usefulness using Microsoft Excel program by verifying a correlation analysis of Aldosterone/PRA ratio and a correlation analysis of Aldosterone/ARC ratio and conducting T-test. Results The regression equation of the PRA(Immunotech company)/ARC(Cisbio company), which was tested in the department, was y = 0.0619x + 0.4615 and the correlation coefficient was 0.73. The regression equation of the PRA(TFB company)/ARC(Cisbio company), which was tested in the other institution, was y = 0.0888x + 0.3316 and the correlation coefficient was 0.91. In addition, The regression equation of Aldosterone / PRA ratio and Aldosterone / ARC ratio was y = 0.875x - 11.688 and the correlation coefficient was 0.87. Plus T - test showed no significant difference (P>0.05). Conclusion Both tests showed a strong positive correlation, but this only represents the strength and direction of the relationship between the two tests. Furthermore, the actual results showed somewhat differences. It is presumed that the measured value was influenced by the endogenous renin group mass in the plasma, the condition of the enzyme reaction and the kind of the inhibitor. When the active renin concentration (ARC) test is performed, it is useful to distinguish between the two tests as they are complementary.

A Study on Welding Performance Improvement of $CO_2$ Inverter Arc Welding Machine by Arc Reignition Detection (아크 재생 검출에 의한 $CO_2$ 인버터 아크 용접기의 용접성능향상에 관한연구)

  • 이정락
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.581-586
    • /
    • 2000
  • Gas metal arc welding(GMAW) uses a continuously fed electrode as a filler metal. The arc is shielded from atmospheric contamination by an inert gas active or inert/active gas mixture delivered through the welding gun and cable assembly. The recent research topics on $CO_2$ are welding machines are focused mainly on the reduction method of generated spatter by using new type consumable electrode metal or inverter control method. The various current waveform control methods have been researched for welding performance improvement. Until now current waveform control methods reduce to spatter occurred by instantaneous short circuiting,. but these methods is drawback that no reduce spatter occurred by arc reignition. In this paper the previous arc reignition current control method for welding performance improvement of inverter arc welding machine is studied and compared the various current control methods with the previous arc reignition current control method.

  • PDF

Analysis of Series Arc-Fault Signals Using Wavelet Transform From Non-linear Loads (웨이블렛 변환을 이용한 비선형 부하 전원선에서의 직렬 아크고장 신호 분석)

  • Bang, Sun-Bae;Park, Chong-Yeun;Jang, Mog-Soon;Choi, Won-HO
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1470-1477
    • /
    • 2008
  • In this paper, a new detection method of series arc-fault signals occurring at the wiring of home appliances is proposed. The discrete wavelet transform was used for the numerical analysis of the variation rate in peak, RMS, noise energy, shoulder of the arc-fault current wave. As a results, the arc distinction threshold value of these variation rates was about 0.1 in most cases. The arc-fault current of the loads with the active PFC circuit showed a high rate of variation in noise energy and shoulder, but arc-fault current of the loads without the active PFC circuit showed a high rate of variation in peak and RMS. The arc fault current in resistive loads showed a high rate of variation in shoulder.

Welding Characteristics of A-TIG Using Various Compositions of Active Fluxes (활성플럭스 조성에 따른 A-TIG용접 특성)

  • Kim, Bong-Hun;Gong, Yong-Soo
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.26-31
    • /
    • 2014
  • Conventional TIG(C-TIG) welding process guarantees higher quality weldment when compared with other processes. However, C-TIG with inherent low penetration shows disadvantages in productivity, especially for thick-walled structure. To overcome these handicaps, active-flux TIG(A-TIG) welding has been introduced and studied widely in a motivation to improve both quality and productivity. Present study made a focus on optimum combination of oxide components to enhance arc contraction and penetration. Results indicated that arc contraction inducing enhancement of penetration could be possible when composition of active fluxes was well matched with base metal.

The Eeffect of Arc Length and Shield Gas on Penetration Aspect Ratio in A-TIG Welding (A-TIG 용접에서 용입 형상비에 미치는 아크길이와 실드가스의 영향)

  • Park, In-Ki;Ham, Hyo-Sik;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.26 no.6
    • /
    • pp.42-47
    • /
    • 2008
  • TIG welding enables to produce high quality weldment. However it has some problems such as shallow penetration and large distortion due to low penetration aspect ratio after welding. In order to overcome those problems, there are many ongoing studies on A-TIG welding, which use active flux. In this study, the effect of arc length and shield gas on penetration aspect ratio with melt-run welding on STS 304 6t, on which active flux was spreaded, was investigated. Arc length was changed from 1mm to 3mm, and aspect ratio became higher as arc length was decreased in this range. 100% Ar gas, Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were used as shield gas in this study. When Ar-$H_2$ mixed gas, Ar-He mixed gas, and 100% He gas were applied, penetration and melting efficiency were both increased as compared with 100% Ar gas. Aspect ratio was the highest with Ar-2.5% $H_2$ mixed gas.

A Study on the Improvement for Power Quality Problems Caused by Electrical Arc Furnace in Power Systems (전력계통에서 전기로 부하에 대한 전력품질 개선방안에 관한 연구)

  • Kim, Jae-Eon;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.444-453
    • /
    • 2007
  • This paper deals with a powerful countermeasure for power quality problems caused by the operation of electrical arc furnace in bulk power systems. The rapid active load fluctuations of electrical arc furnace could produce several problems such as voltage flicker and active power oscillations. The typical methods using only the reactive power compensation have their own limitation in solving the power quality problems caused by active load variations. The coordination of both active and reactive power compensation is required to solve the power quality problems. This paper focuses on the impacts and the dynamic phenomena caused by the active load fluctuation. This paper proposes the optimal algorithm for the active power compensation based on the function of 1(n ratio and the concepts for the active power compensation. The results from a case study show that the proposed methods can be a practical tool for the power quality problems in power systems.

  • PDF

Power Quality Impacts of an Electric Arc Furnace and Its Compensation

  • Esfandiari Ahmad;Parniani Mostafa;Mokhtari Hossein
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.153-160
    • /
    • 2006
  • This paper presents a new compensating system, which consists of a shunt active filter and passive components for mitigating voltage and current disturbances arising from an Electric Arc Furnace (EAF). A novel control strategy is presented for the shunt active filter. An extended method based on instantaneous power theory in a rotating reference frame is developed for extraction of compensating signals. Since voltages at the point of common coupling contain low frequency interharmonics, conventional methods cannot be used for dc voltage regulation. Therefore, a new method is introduced for this purpose. The passive components limit the fast variations of load currents and mitigate voltage notching at the Point of Common Coupling (PCC). A three-phase electric arc furnace model is used to show power quality improvement through reactive power and harmonic compensation by a shunt active filter using the proposed control method. The system performance is investigated by simulation, which shows improvement in power quality indices such as flicker severity index.

Stability of a magnetic structure producing an M6.5 flare in the active region 12371

  • Kang, Jihye;Inoue, Satoshi;Kusano, Kanya;Park, Sung-Hong;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.83.2-83.2
    • /
    • 2019
  • We study the stability of the magnetic structure in active region (AR) 12371 producing an M6.5 flare on June 22 2015. We first perform a nonlinear force-free fields (NLFFFs) extrapolation to derive three-dimensional (3D) magnetic fields based on time series of observed photospheric magnetic fields. The NLFFFs well describe an observed sigmoidal structure with the shape of a double arc magnetic configuration. Next, we examine three possible instabilities (kink, torus, and double arc) to investigate how the M6.5 flare is triggered in the double arc loops. Consequently, the double arc loops are stable against kink and torus instabilities, but possibly unstable against the double arc instability before the flare occurrence. Finally, we discuss a probable scenario for the M6.5 flare.

  • PDF