• Title/Summary/Keyword: Activated carbon filter

Search Result 154, Processing Time 0.02 seconds

A Study of Filtralite Media Applicability for Development F/A Process of Membrane Filtration Pre-treatment Process in the Water Purification Plant (정수장에서 막여과 전처리용 F/A 공정 개발을 위한 Filtralite 여재의 적용성 연구)

  • Kim, JUN-Hyun;Jun, Yong-sung;Kwak, Young-ju;Jang, Jung Woo
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.503-514
    • /
    • 2015
  • In this study, water purification system without coagulant was consisted of F/A and membrane to produce purified water which only uses physical treatment without coagulant. Because the use of coagulant has a possibility remaining of hazardous aluminum with our health. Especially, the Filtralite was reviewed the possibility to remove turbidity and organic material. It was found that the turbidity removal rate of Filtralite was 83~84%. It show that Filtralite has similar efficiency to sand-filter. But Filtralite has higher 50% removal rate of organic material than sand-filter due to well-developed pore on the surface of it. So, Filtralite could be used to substitute the sand-filter for the F/A process due to higher removal rate. And also coupled with activated carbon in F/A process, TMP was increased by TOC value. To prevent increasing TMP, media that has outstanding organic adsorption ability should be used.

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF

Oxidation of Soot Particles with O Radicals Generated in a AC Streamer Corona Discharge (AC 스트리머 코로나 방전으로 생성된 O 라디칼과 매연 입자의 산화반응)

  • Kim, Pil-Seung;Lee, Kyo-Seung;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • Carbon soot emission from combustion processes, especially from diesel engines, is a subject of growing concern since soot is known to seriously affect human health. Efforts have been made to oxidize soot particles utilizing Non-Thermal Plasma(NTP) techniques. When oxygen is carried into a plasma device, electrons generated by the plasma dissociate the oxygen, resulting in the formation of oxygen atoms. These highly activated atoms, called O radicals, are known as strong oxidizing agent. This paper presents concentration variations of CO and $CO_2$ at the exit of the plasma device, resulting from the soot oxidation by O radicals, with variations of inlet oxygen concentration, gas temperature, and gas flow rate. Based on the data, Arrehenious rate constants of reactions between C(s)+O and C(s)+O+O were proposed.

  • PDF

Electrochemical Removal Characteristics of Disinfection By-products by Chlorination in Drinking Water (음용수내 발암물질인 염소 소독부산물의 전기화학적 제거 특성)

  • Kwon, Sun-Woo;Lee, Jong-Dae;Sin, Jang-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.364-369
    • /
    • 2004
  • It has been confirmed that some Trihalomethanes (THMs) suspected as carcinogens, can be formed during chlorination for water supply through the reaction of chlorine and humic substances in water. The electrochemical characteristics on activated carbon fiber filter (ACF) electrode were investigated to remove the THMs in the chlorination process of drinking water. The electrochemical removal efficiency depended on the applied voltage and flow rate. In this study, the best result showed that the removal efficiency of THMs was higher than 99%.

Manufacturing technique of dustproof mask filter using meltblown(M/B) non-woven with activated carbon (활성탄 부착 Meltblown(M/B) 부직포를 이용한 방진마스크용 여과재 제조기술개발)

  • 홍영기;전재완;이재달;송인희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.84-86
    • /
    • 2001
  • 본 논문에서는 고성능 활성탄의 악취 및 유해가스 흡착효율과 멜트브로운(M/B)부직포의 여과성능에 의한 복합적인 고기능 방진특성을 갖는 활성탄 부착 M/B 국산화 여과재를 제조개발하였다. 고성능 활성탄은 고순도의 일반활성탄에 금속염, 유기물 등을 담지시켜 활성화시킨 활성탄이고, M/B여과재의 웹(web)제조조건은 M/B 방사기에서 방사온도 250℃, 방사속도 150m/sec, 고온공기온도 250℃ 그리고 DCD(die to collector distance) 20cm가 적합함을 알 수 있었다. 또한 M/B 여과재에 활성탄 부착은 열롤러시스템에 의한 열적결합방법을 이용하여 균일한 분포의 점접착결합구조를 갖도록 하였고, 개발된 복합기능 여과재가 방진마스크용 여과재로의 이용이 가능하다는 것을 분진포집효율, 투과율, 흡기저항 등 여과재 성능기준실험 결과를 통해 확인하였다.

Treatability Study on the Remediation Groundwater Contaminated by TPH Cr6+ : Lab-Scale Experiment (TPH와 6가 크롬으로 오염된 지하수 처리를 위한 실내 실험)

  • Lee, Gyu-Beom;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.332-345
    • /
    • 2019
  • The purpose of the study is to evaluate the treatability of contaminated groundwater with TPH and (or) $Cr^{6+}$. Laboratory scale tests were performed for oil/water separation, dissolved air flotation (DAF), coagulation and precipitation, and filtration with sand and activated carbon respectively. Two times of oil/water separation tests for total 40 minutes of separation or separating time shows 90.2 % of TPH removal rate. In case of DAF test for high TPH sample, the TPH removal rates were not varied significantly by the variation of microbubble size. However, tests for low TPH samples show that TPH removal rate increases as microbubbles are smaller. When coagulant was added to sample for DAF test, TPH removal rate was increased 12.3 %. SS removal rate by DAF was 97.9 % at $16-40{\mu}m$ and it was increased as the size of microbubble is reduced. Tests for coagulation and precipitation were performed to evaluate the removal of $Cr^{6+}$ in groundwater. The increase of $FeSO_4$ dosage increased $Cr^{6+}$ removal rate in the coagulation and precipitation process. As the amount of activated carbon in the filter media increased TPH removal rate in the filtration process. SS removal rate by the filtration was 96.7 % similar to the results of DAF process tests. The filtration process treats TPH and SS. Best design parameters are determined as the size of sand is $425-850{\mu}m$ and the ratio of activated carbon and sand is 50:50.

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

Evaluation of Performance and Economical Efficiency of the Advanced Wastewater Treatment System (고도(高度) 하수처리(下水處理) 시스템의 처리성능 및 경제성 평가에 관한 연구)

  • Kim, Dong Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.61-71
    • /
    • 1999
  • For a high-rate fermentation and recovery of organic acid, we have developed a new organic acid fermentation reactor with membrane filter, which is the most important part in the new advanced wastewater treatment system. The recovered organic acid is to be reused as an organic carbon source at denitrification process. Some experiments were conducted to compare the performance of acid fermentation at different SRTs, such as 5, 10, and 20 days. The total organic acid concentration produced during the runs was in the range of 2,100-2,900 (mgC/L). The conversion efficiency from substrate to organic acid reached to from 43% to 59%. The recovery rate of organic acid from substrate based on TOC was from 26% to 53%. Regardless of operational conditions, it has been able to maintain the membrane flux constantly, in the range of 0.4-0.46 ($m^3/m^2/day$). The transmembrane pressure drop was 0.2-0.3 (kg/cm) for 100 day's operation. The result of simulation is as follows. Organic removal efficiency of the new advanced treatment system is 95%. 73% of Nitrogen is removed. The removal efficiency of Phosphorus is 93%. By coqulation, soluble phosphorus is able to remove from the water treatment lines, which is impossible at conventional activated sludge system. The unit construction cost is 65000 (yen/m3) and it was 1.4 times than that of the standard activated sludge system. The unit operation cast is 7.7 ($yen/m^3/day$) and it was 1.3 times than that of the standard activated sludge system.

  • PDF

Simultaneous Removal of TVOC and Particulate Matters Using Rectangular Bag-Filter System with for a Foundry (주물공정 악취·분진 동시 처리를 위한 여과 집진장치 개발연구)

  • Xu, Rong-Bin;Kim, Tae-Hyeung;Ha, Hyun-Chul;Piao, Cheng-Xu
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1409-1418
    • /
    • 2014
  • Foundry has an important economic value in the industry. However, the generation of air pollutants like particulate and odor are serious. Due to the unavoidable usage of molding sand, particulate occurs in almost all the processes. That accounts for the majority of respirable dust in the size less than $10{\mu}m$ As well as particulate, over 22 species of odor-causing gases and VOCs including hydrogen sulfide and ammonia are occurred. Therefore, the development of equipment that can simultaneously remove TVOC and particulate is regarded as an essential research. In this study, the spraying absorbent system was connected with the shear bag filter for the purpose to remove TVOC and particulate simultaneously. Maximization of process efficiency for the affective factors like the powder combination and injection method is conducted. The experiment was performed at the de-molding process of one foundry plant. Through these devices, the removal efficiency of more than 95% for TVOC was achieved with the absorbent that composed by 800 mesh Activated carbon (80%) and 300 mesh zeolite (20%). Also, the durability and economic evaluation were assessed. In the result of Durability assessment, the available recovery to maintain the deodorizing effect at 90% was counted to 350 degree.

The Removal Characteristics of THM Formation Potential According to the Changes of Bromide Concentration of Influent Water in BAC Process (생물활성탄 공정에서 계절별 유입수의 $Br^-$ 농도변화에 따른 THM 생성능 구성종별 제거 특성)

  • Son, Hee-Jong;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.5
    • /
    • pp.378-381
    • /
    • 2009
  • The purpose of this research is the evaluation of removal efficiency of THMFP in BAC. The changes of four types of THMFP and total THMFP were examined in the influent and effluent of BAC filter from March to December in 2008. It turned out that the amounts of brominated THMFP were obviously higher in winter and autumn compared to the spring and summer, which also resulted in an increase of the total-THMFP levels during winter and autumn. In addition, long-term running of BAC filter shows the good removal function of chloroform formation potential, but not brominated THMFP; with further bromination, this function was declined, as it shows the formation of bromoform in BAC filter during October and December. These results were caused by changing of the proportion of $Br^-$/DOC.