Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.
초기의 접착 시스템은 여러 단계의 술식을 필요로 하였으며 술자의 기술과 재료의 성질에 크게 좌우되었으나 최근 산부식, priming, adhesive를 한번에 적용할 수 있는 all-in-one adhesive system이 등장하였다. 치과에서의 vibration의 이용은 치석의 제거 및 접착제의 점도를 낮추는데 이용되어왔으며 vibration은 접착제의 흐름성을 향상시켜 film thickness를 낮추어 수복물 주위의 미세누출을 줄이는데 도움을 준다. 이에 저자들은 all-in-one adhesive system에서 vibration이 법랑질과 상아질의 접착강도와 레진침투에 미치는 효과를 알아보고자 하였다. 법랑질 시편은 발거 후 실온에서 0.1% thymol 용액에서 보관된 30개의 건전한 사람의 대구치를 무작위로 10개씩 세군으로 나누고 근원심 방향으로 두 부분으로 분리하여 각각은 같은 접착제를 사용하고 초음파진동여부를 다르게 하였고, 아크릴레진을 이용하여 직경 1-inch의 PVC관에 매몰한 후 협설면이 아크릴봉과 동일한 높이가 되도록 220-, 600-grit 연마지로 순차적으로 연마하였고 군당 10개씩 여섯 군으로 분류하였다. 1군과 2군은 Prompt L-Pop(3M-ESPE, Seefeld, Germany), 3군과 4군은 One-Up Bond F(Tokuyama Corp., Tokyo, Japan), 5군과 6군은 AQ bond(Sun Medical Co., Kyoto, Japan)를 제조사의 지시에 따라 도포하였다. 2군, 4군, 6군은 초음파 치석제거기를 이용하여 치면에 대고 15초간 진동을 가한 후 광중합하였다. 상아질 시편은 치관부 법랑질을 제거한 후 상아질면을 아크릴 봉과 동일한 높이가 되도록 하고 법랑질 시편과 동일하게 처리하였다. 이후 직경 2mm, 높이 3mm의 Teflon mold(Ultradent, U.S.A.)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합한 후 24시간동안 실온에서 증류수에 보관하였다. 열순환 시행한 후, 만능측정기(Instron 4465)로 전단결합강도를 측정하였으며 Resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 완전히 용해시킨 후 표면을 주사전자현미경사진으로 관찰하여 다음과 같은 결과를 얻었다. 1 법랑질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그 차이는 Ad bond 군을 제외하고 통계적으로 유의하였다(p<0.05). 2. 상아질에서 초음파 진동을 가한 군(2, 4, 6군)은 가하지 않은 군(1, 3, 5군)에 비해 평균 전단결합강도가 높게 나타났다. 그러나 그 차이는 One-Up Bond F군을 제외하고는 통계적으로 유의한 차이가 없었다. 3. 전자 현미경 관찰에서 초음파 진동을 가한 군에서 더 많은 법랑질의 소실과 상아질에서 resin tag의 길이가 길었고 lateral branch의 수도 많이 관찰되었다.
초음파 진동을 치의학에 처음 이용한 것은 치석 제거기였으나, 최근에는 주조금속과 레진 인레이를 접착할 때, 인산아연시멘트나 레진시멘트의 점도를 낮추는데 이용되고 있다. 이러한 초음파 진동은 재료의 흐름성을 증가시킴으로써 피막도를 낮추고, 따라서 수복물 주위의 미제누출을 감소시킬 수 있는 장점이 있다. 그러나, 복합레진의 수복에 있어서 이러한 초음파 진동의 임상적 효과에 관한 연구가 아직까지 미흡한 실정이다. 이에 저자는 초음파 진동을 상아질 결합제에 적용하여 점도를 감소시킴으로써 상아세관으로의 레진 침투 정도의 변화와 결합력에 미치는 효과를 알아보고자 하였다. 발거 후 실온의 0.1% thymol 용액에 보관된 88개의 건전한 사람의 대구치를 치관부 법랑질을 제거하고 아크릴 레진을 이용하여 직경 1-inch의 PVC 관에 매몰하였다. 각 시편의 교합면이 아크릴봉과 동일한 높이가 되도록 220-, 500-grit의 연마지로 순차적으로 연마하였고, 무작위로 추출하여 각 군당 22개씩 네 군으로 분류하였다. 1군과 2군은 Single Bond(3M-ESPE, St. Paul, USA)를 3군과 4군은 One-Step(Bisco Inc., Schaumburg, USA)을 제조사의 지시에 따라 치면을 산부식, 수세, 건조한 후 연속하여 2번을 도포하였다. 2군과 4군은 초음파 치석제거기를 이용하여 치면에 대고 10 초간 진동을 가한 후 광중합하였다. 이후 직경 2.3mm, 높이 3.5mm의 Teflon mold(Ultradent Products Inc., South Jordan, USA)를 이용하여 복합레진을 충전한 후 40초씩 두 번에 나누어 광중합하였다. 모든 시편은 24시간 동안 실온의 수도물에 보관한 후 열순환을 시행하고, 만능측정기(Instron 4465, Canton, USA)로 전단결합강도를 측정하였으며 resin tag의 양상을 비교하기 위해 각 군의 시편의 치질을 탈회시킨 후에 표면을 주사전자 현미경으로 관찰하여 다음과 같은 결과를 얻었다. 1. 초음파 진동을 가하지 않은 1군, 3군에 비해 초음파 진동을 가한 2군과 4군에서 전단결합강도가 유의하게 높게 나타났다(p<0.05). 2. Single Bond와 One-Step의 전단결합강도는 유의한 차이를 보이지 않았다(p>0.05). 3. 전자현미경 관찰에서 초음파 진동을 가한 군에서 resin tag의 길이가 길었고, lateral branch의 수도 많이 관찰되었다.
In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.
폐구성 과두 걸림이라고도 하는 비정복성 관절원판변위는 관절원판이 과두로부터 전위되어 과두 운동 시에 정상위치로 되돌아가지 않는 임상상태를 말한다. 비정복성 관절원판변위가 급성으로 나타난 경우에는 초기 치료에서 수조작에 의한 관절원판의 정복을 시도하여야 한다. 일반적으로 과두 걸림 발생 후 1주일 이내에 수조작술을 시행하는 경우에는 대개 성공적으로 관절원판이 정복되는 경우가 많지만 그 이상 경과된 경우에는 성공률이 떨어지는 것으로 알려져 있다. 수조작술을 통해 관절원판의 정복이 일어난 이후에는 전방위치 교합장치를 즉시 장착시켜서 폐구성 과두 걸림이 다시 발생하지 않도록 하는 것이 좋다. 하지만 전방위치장치를 제작하는데 시간이 많이 소요되므로 임상에서 즉시 제작하여 장착하기는 현실적으로 어려운 경우가 많다. 또한 전방위치장치를 제작하기 전까지 자가 중합 아크릴릭 레진을 이용한 임시 전방위치 장치를 제작하여 사용하는 방법도 레진의 냄새로 인한 불편감 및 시간 소요 등으로 널리 이용되고 있지는 않다. 또한 레진 알러지가 있거나 교정 치료 중이어서 레진을 사용하기 어려운 경우, 또는 행동조절이 불가능한 일부 환자들에게는 이 장치를 적용하기 어렵다. 따라서, 수조작술을 통해 관절원판이 정복된 경우 레진 대신 퍼티 고무 인상재를 이용하여 임시 전방장치를 제작한 후 단기간 적용하여 폐구성 과두 걸림을 치료한 증례를 통해 그 효용성을 확인해 보고자 하였다.
During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.
산 처리방법에 따른 상아질 접착을 평가하고 표면처리 후의 상아질 표면의 성상변화 및 파단면의 양상을 관찰하기 위해 발거된 구치 에 10% polyacrylic acid (GC Dental Industrial Corp., U. S. A.), 10 % 인산(Bisco Inc., U. S. A.) 및 10-3 용액 (Parkell Bio-Materials, U. S. A.)을 사용하여 상아질 표면을 처리하고 모든 시편에 상아질 접착제인 All Bond 2$^{(R)}$(Bisco Inc., U.S.A.)를 도포하였으며 복합레진 (Silux Plus$^{(R)}$, 3M Co., U.S.A.)을 첨가한 후 접착강도를 측정하고 상아질 표면 및 파단면을 주사 전자현미경으로 관찰, 비교하여 다음과 같은 결과를 얻었다. 1. 접착강도는 상아질 표면을 산 처리한 군이 무처리한 대조군에 비해 높게 나타났고, 산처리를 시행한 군들 간에는 10-3 용액으로 처리한 군이 가장 높았으며 10% 인산으로 처리한 군, 10% polyacrylic acid로 처리한 군의 순이었다(p<0.01). 2. 상아질 표면의 관찰에서, 무 처리의 상아질 면은 상아세관이 개방되지 않은 채 도말층으로 덮혀 있었고, 10% polyacrylic acid로 처리한 상아질 면은 도말충이 제거되고 상아세관이 개방되어 있었으나 상아세관 내에 smear plug이 일부 남아 있었으며, 10% 인산또는 10-3 용액으로 처리한 상아질 면은 도말층 및 smear plug이 모두 제거되고 상아세관이 완전히 개방되어 있음이 관찰되었다. 3. 파단면의 관찰에서, 무 처리군에서는 도말층 내에서 파단이 일어났으며, 10% polyacrylic acid로 처리한 군에서는 상아세관 내 잔존 레진 tag이 관찰되지 않았으나 10% 인산 및 10-3 용액으로 처리한 군에서는 상아세관 내의 잔존 레진 tag이 관찰되었다. 4. 파단 양상에 있어서, 접착강도가 큰 군일수록 응집성 파단의 빈도가 증가되어 나타났으며, 각 시편에서 구한 접착강도와 응집 파단율의 상관 계수는 0.71이었다.
The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.
연구 목적: 포스트로 수복한 치아의 미세누출을 방지하기 위한 다양한 술식이 개발되고 있고 이에 본 연구에서는 다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 치근부 미세누출에 대해 비교 연구하고자 하였다. 연구 재료 및 방법: 36개의 근관치료된 상악 영구 중절치를 3가지 포스트 그룹으로 분류하였다: Zirconia-glass fiber, Quarze-glass fiber, Polyethylene fiber 포스트. 포스트 공간이 형성되었고 각 포스트는 세가지 접착시스템으로 접착되었다: 3-stage total-etch adhesive, 2-stage total-etch adhesive, 1-stage self-etch adhesive. 각 시편들을 2% 메틸렌 블루 용액에 1주일 동안 담구었다. 세척한 시편을 자가중합 아크릴릭 레진에 포매하였다. 각 시편을 치근단, 중앙, 치관 부위로 수평 절단하였다. 메틸렌 블루가 침투된 각 시편의 절단부를 교합면 측에서 stereomicroscope로 측정하였다. 시료 침투량은 메틸렌 블루 침투 표면과 총 상아질 표면의 비율로 평가하였다. 결과: 모든 절단부위에서 모든 군들은 미세 누출을 보였다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었다. All Bond 2로 접착한 3단계 접착시스템으로 처리한 치아 중앙절편에서 zirconia-glass fiber와 quarze-glass fiber 포스트 간, zirconia-glass fiber와 polyethylene fiber 포스트 간, quarze-glass fiber와 polyethylene fiber 포스트 간에 미세누출에는 유의한 차이가 있었다(P<.05). 각각의 포스트의 치근단과 치관 부위 사이에는 유의한 차이가 있었고, quarze-glass fiber와 polyethylene fiber 포스트에서 치근단과 중앙 부위 사이에 유의한 차이가 있었다(P<.05). 결론: 포스트 종류에 따른 접착 시스템 간에 미세누출의 유의한 차이가 없었다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었으나, 유일하게 3단계 접착시스템으로 처리한 포스트의 중앙절편에서 zirconia-glass fiber가 다른 포스트에 비해 유의하게 적은 미세누출을 보였다.
Er:YAG 레이저를 이용한 치아경조직 삭제의 효율과 안전도는 물분사량, 조사시간, 조사방법, 에너지, 조사반복율 등의 다양한 변수에 의해 좌우된다. 이 연구의 목적은 출력을 고정한 상태에서 에너지와 조사반복율을 달리하였을 때 삭제율과 치수내 온도변화가 어떤 요소에 의해 더 많이 좌우되는지를 평가하고자 하였다. 발거된 건전 대구치를 두 조각으로 나누어 치아표본을 준비하여 $300mJ{\times}10Hz$, $200mJ{\times}15Hz$, 및 $150mJ{\times}20Hz$의 조건에서 1.6 ml/min의 물을 분사하면서 법랑질표면에 3초간 Er:YAG 레이저를 조사하였다. 레이저 조사 전후의 치아 무게를 측정하여 그 차이로 삭제율을 평가하였다. 각 군당 표본은 10개로 하였다. 위의 조건에서 발생하는 치수내 온도변화를 평가하기 위하여 발거된 건전한 대구치를 이용하여 access cavity를 형성하고 치수조직을 제거한 다음, hard acrylic resin으로 만든 block에 치아를 매식하고 레이저를 조사되는 측 치수벽과 반대측 치수벽에 온도측정탐침을 위치시켜 레이저조사과정과 그 후에 발생하는 온도변화를 측정하였다. 조사조건은 삭제율 평가시와 동일하게 하였으며 각 군당 표본은 5개로 하였다. 실험의 결과, 3W의 출력에서 치아삭제량은 펄스에너지의 증가에 따라 함께 증가되었다.(p=0.000) 반면에 치수 내 온도는 조사반복율의 증가에 의해 상승되었으나 각 군별, 조사측간에 유의한 차이는 없었다. 다만, $150{\times}20Hz$의 조사조건에서만 조사측 치수벽이 반대측에 비해 유의한 온도증가를 보였다(p=0.033). 본 연구의 결과는 Er:YAG 레이저의 치아삭제율은 조사반복율보다 펄스에너지의 영향을 많이 받는다는 점을 시사하고 있다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.