• 제목/요약/키워드: Acrylic resin system

검색결과 73건 처리시간 0.027초

접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출 (SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT)

  • 박주식;이석종;문주훈;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF

입자영상유속계를 이용한 분기관내 유동가시화 (Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry)

  • 노형운;서상호;유상신
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.29-36
    • /
    • 1999
  • 본 연구는 목적은 PIV 시스템을 이용하여 분기관내 유동현상을 가시화하여 분기부 영역의 유동특성을 분석하는데 있다. PIV 시스템으로 유동장을 가시화하기 위해서 분기관 모델은 투명 아크릴판으로 제작하였고 작동유체와 추적입자는 각각 물과 송화가루를 사용하였다. 유동장에서 획득된 영상으로부터 속도벡터를 얻기 위해서 입자추적방법의 1-프레임 법과 2-프레임 법, 상호상관 PIV법인 2-프레임법을 사용하였다. PIV 시스템으로 측정된 실험결과의 신뢰성을 확보하기 위해서 표면구동 캐비티 유동의 속도분포를 4-프레임법으로 얻어진 기준 실험 데이터와 비교하였다. 분기관에서 뉴턴유체의 유동현상을 효과적으로 가시화하는데 필요한 상호상관 PIV방법의 2-프레임법을 적용하는 알고리즘을 개발하였고, sub-pixel과 면적보간을 사용하여 오벡터를 제거후 최종속도벡터를 얻었다. PIV를 이용한 분기관내 유동가시와 실험결과를 신뢰할 수 있는 수치해석 결과를 이용하여 검증한 결과 PIV 실험으로 얻어진 속도벡터는 수치해석의 결과와 잘 일치하였다. PIV 실험과 수치해석 결과로부터 분기관모델의 분기점 원위부에 재순환영역이 형성됨이 확인되었고 두 다른 방법을 이용한 재순환영역의 길이와 높이는 거의 동일하였다.

  • PDF

CAD/CAM system으로 제작한 zirconia core의 적합도 (THE FIT OF ZIRCONIA FORE FABRICATED WITH CAD/CAM SYSTEM)

  • 성지윤;전영찬;정창모;임장섭
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.489-500
    • /
    • 2004
  • Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpose : This study was to evaluate the fit related to internal relief and marginal reproducibility of zirconia core fabricated with CAD/CAM system. Materials and methods: The evaluation was based on 30 zirconia cores and 5 IPS-Empress2 cores. Zirconia cores were fabricated in different conditions of internal relief(0, 10, 20, 30, 40 and $50{\mu}m$), and IPS-Empress2 cores were fabricated in accordance with the manufacturer's instructions. Before cementation, the marginal discrepancies or cores were measured on metal die. And then, each core was cemented to stone die, embedded in an acrylic resin and sectioned in two planes(mesiodistally and labiopalatally). The internal gaps were measured at the margin and axial surface. Measurements for the marginal discrepancies, the internal marginal gaps and the internal axial gaps were performed under a measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of ${\times}100$. In addition, the marginal conagurations of metal die, zirconia core and IPS-Empress2 core were examined with SEM(S-2700, Hitachi, Japan). Results : Within the limits of this study the results were as follows. 1. Compared with IPS-Empress2 cores, the marginal discrepancies of zirconia cores had no significant differences. the internal marginal gaps were statistically smaller and the internal axial gaps were statistically larger in each condition of internal relief. 2. The marginal discrepancies and the internal marginal gaps of zirconia cores had no significant differences related to the conditions of internal relief(P>0.05). 3. The internal axial gaps of zirconia cores with $0{\sim}20{\mu}$m for internal relief were significantly larger than that with $50{\mu}m$ (P<(0.0001). 4. SEM micrographs showed favorable marginal reproducibility of zirconia core and smooth texture on the milling surface. Conclusion: The marginal discrepancy and the internal gaps of zirconia core were clinically acceptable and the milling surface was showed smooth texture. For fabrication of the durable esthetic restoration, further investigations on complex design of core, milling accuracy, compatability of enamel porcelain and porcelain firing seems to be needed.

광산폐석의 효과적 처리를 위한 지화학적 연구 (Geochemical Experiment for Effective Treatment of Abandoned Mine Wastes)

  • 이진국;이재영
    • 한국토양환경학회지
    • /
    • 제3권1호
    • /
    • pp.31-44
    • /
    • 1998
  • 본 연구는 중금속원소의 주오염원 중의 하나인 금속폐광산에 다량 잔존하는 폐석을 효율적으로 처리하기 위해 실내모형시험을 수행하였으며, 그 결과를 광산폐석처리의 기술개발에 기초자료로 활용하고자 한다. 실험의 도구는 실험결과에 거의 영향이 없는 내산성 내알카리성의 아크릴산수지와 폴리에틸렌 관을 사용하였다. 본 연구에서 제작 운용된 8개의 모형을 계내의 환경, 충진물의 배열방식 및 종류 등으로 분류한다면 4개의 그룹으로 나눌 수 있다. 그룹 1은 계내에 폐석으로만 충진하여 개방계에서 실험한 배경모델이고, 그룹 2는 각각 두 개의 폐석층과 석회암편층을 층상으로 배열한 뒤 개방계와 폐쇄계로 구분하여 실험하였다. 그룹 3은 폐석과 석회암편을 골고루 잘 섞어 계내에 충진하고(혼합모델)이를 개방계와 폐쇄계로 구분하여 실험하였으며, 마지막 그룹 4는 폐석층의 표층부에 석회암편층을 가하여 실험하였다. 배경모델인 모델 Ⅰ로부터 배수된 시수는 실험초기부터 말기까지 중금속원소의 용존량이 매우 높다. 그런, 다른 모델에 비해 그룹 3에 해당되는 모델 Ⅴ와 Ⅶ은 중금속원소의 함량이 매우 낮아 제거효과가 가장 높은 것으로 나타났다. 폐쇄된 혼합모델에서 폐석과 석회암편의 혼합비를 1:1, 2:1로 달리하더라도 중금속원소의 제거효과 는 대동소이한 것으로 나타났다. 그러나, 계내를 같은량의 충진물로 충진하더라도 혼합모델은 층상모델에 비해 중금속원소의 제거효과가 현저히 높다. 그리고, 다른 실험조건이 같은 폐쇄계와 개방계를 비교하면 전자의 중금속원소의 제거효과가 다소 높은 것으로 나타났다.

  • PDF

니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도 (Shear bond strength of Universal bonding systems to Ni-Cr alloy)

  • 송소연;손병화;김종엽;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제53권4호
    • /
    • pp.295-300
    • /
    • 2015
  • 목적: 레진과 니켈-크롬 합금의 결합력에 미치는 금속 프라이머 및 다용도 접착제의 영향에 대하여 비교 평가하고자 한다. 재료 및 방법: 실험을 위해 120개의 니켈-크롬 합금(Vera Bond 2V) 디스크를 제작하여 아크릴 레진 실린더에 포매하였다. 시편의 표면은 220 grit, 600 grit의 실리콘 카바이드지로 연마한 뒤 $50{\mu}m$의 알루미늄옥사이드 입자를 분사하여 처리하였다. 실험군은 메탈 프라이머의 적용(Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer)과 다용도 접착 시스템(Single Bond Universal, All Bond Universal)에 따라 6개 군으로 나뉘었다. 각 시편의 중앙에 높이 2 mm, 직경 3 mm로 복합레진을 충전하였으며, 제작된 모든 시편은 $37^{\circ}C$ 증류수에서 24시간 보관하였다. 만능시험기에 시편을 위치시킨 후 1 mm/min cross head speed로 전단결합강도를 측정하였다. 통계분석은0.05의 유의수준으로 일원분산분석을 시행하였고 Tukey's multiple coMParison test로 사후검정을 하였다. 결과: Single Bond Universal, All Bond Universal, Metal Primer II 3개 군과 Alloy Primer, MKZ Primer, Metal & Zirconia Primer 3개 군 사이에 통계학적으로 유의한 차이를 보였다(P<.001). 결론: 니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도는 Metal Primer II를 제외한 기존의 금속 프라이머를 적용했을 때 보다 높게 나타났다. 본 실험에서 더 나아가 다용도 접착 시스템 내 실란(Silane) 포함 여부에 따른 효과를 평가할 수 있는 연구가 필요할 것이다.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제42권6호
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교 (COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST)

  • 김미경;김석규
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

Volumetric accuracy of cone-beam computed tomography

  • Park, Cheol-Woo;Kim, Jin-ho;Seo, Yu-Kyeong;Lee, Sae-Rom;Kang, Ju-Hee;Oh, Song-Hee;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제47권3호
    • /
    • pp.165-174
    • /
    • 2017
  • Purpose: This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. Materials and Methods: Four geometric objects(cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The objects consisted of Teflon-perfluoroalkoxy embedded in a hydrocolloid matrix (Dupli-Coe-Loid TM; GC America Inc., Alsip, IL, USA), encased in an acrylic resin cylinder assembly. An Alphard Vega Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) was used to acquire CBCT images. OnDemand 3D (CyberMed Inc., Seoul, Korea) software was used for object segmentation and image analysis. The accuracy was expressed by the volume error (VE). The VE was calculated under 3 different exposure settings. The measured volumes of the objects were compared to the true volumes for statistical analysis. Results: The mean VE ranged from -4.47% to 2.35%. There was no significant relationship between an object's shape and the VE. A significant correlation was found between the distance of the object to the center of the image and the VE. Tube voltage affected the volume measurements and the VE, but tube current did not. Conclusion: The evaluated CBCT device provided satisfactory volume measurements. To assess volume measurements, it might be sufficient to use serial scans with a high resolution, but a low dose. This information may provide useful guidance for assessing volume measurements.

교두감합위로부터 출발한 수직교합고경의 단계적 증가가 사지 근력에 미치는 영향에 관한 연구 (The Effect of Human Appendage Muscle Strength on Increase in Vertical Dimension from Intercuspal Position of Mandible)

  • 홍동희;이성복;최대균
    • 구강회복응용과학지
    • /
    • 제19권3호
    • /
    • pp.169-183
    • /
    • 2003
  • According to our recent investigation that the increase in the occlusal vertical dimension made the appendage muscle strength got higher, the occlusal appliances were made by increasing the occlusal vertical dimension "from the centric relation" position of the mandible. In this experiment, the authors tried to study the change in the appendage muscle strength due to increase in occlusal vertical dimension from intercuspal position(ICP) of mandible with the same subjects and manner as the former experiment. For this study, ten male athletes in a mean age of 23 year who were joined the former study were selected. All the subjects had a complete or almost complete set of natural teeth and reported no subjective symptoms of temporomandibular disorders. Upper and lower casts were mounted on the semi-adjustable articulator at the intercuspal position and a point was marked on the attached gingival area between the right canine and the right 1st. premolar in each upper and lower cast. From the points, the occlusal vertical dimension was increased by 2mm, 3.5mm and 5mm, and then each 10 maxillary type occlusal splint at each 3-increased position were fabricated with heat curing clear acrylic resin. Including the intercuspal position, the 3 kinds of occlusal splints were placed on the subjects individually, and then isokinetic muscle strength on 7 parts of the human appendage which are shoulder, knee, ankle, wrist, forearm, elbow and hip was measured with the CYBEX 6000 SYSTEM (Lumex, NewYork, USA). The results were as follows: The highest mean value in muscular strength was shown at the position of 2mm-increased vertical dimension. The muscle strength during internal/external rotation of shoulder and knee, plantarflexion of ankle, flexion of elbow, and flexion and extension of hip at the increased occlusal vertical dimension position were significantly higher than them at the intercuspal position (p<0.05). Only in view of the increase in the appendage muscle strength, regardless of the way of making the occlusal splints by elevating the occlusal vertical dimension from the centric relation position or intercuspal position, the occlusal splints had an effect on the increase of isokinetic muscle strength at the occlusal vertical dimension which increased within the proper range on the habitual arc of closure.

다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구 (Detorque values of abutment screws in a multiple implant-supported prosthesis)

  • 이주리;이동환;황재웅;최정한
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.280-286
    • /
    • 2010
  • 연구 목적: 본 연구는 다수의 임플란트에 의해 지지되는 보철물을, 두 가지 인상법에 의해 얻은 모형들에 연결한 후, 나사의 풀림 토크값을 측정하여 나사 결합부 안정성에 차이가 있는지를 알아보는데 그 목적이 있다. 연구 재료 및 방법: 네 개의 외부 육각 임플란트 (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB)에 직접 연결되는 임플란트 상부 구조물과, 이와 수동적 적합을 갖는 완전 무치악 하악주모형을 만들었다. 이 주모형에서 비연결 인상법으로 6회 인상을 채득하여 6개의 모형 (1군)을 제작하고, 아크릴릭 레진을 이용한 연결 인상법으로 6회 인상을 채득하여 6개의 모형 (2군)을 제작하여, 총 12개의 실험모형을 제작하였다. 각 실험모형에 상부 구조물을 지대주 나사 ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB)로 20 Ncm의 힘으로 조인 후 각 나사의 풀림 토크값을 총 2회 측정하였다. 두 군 간 나사의 풀림 토크값의 비교를 위한 통계분석은 반복측정을 고려하고 나사와 reading을 고정효과로, 모형을 랜덤효과로 포함하는 혼합모형 (mixed model)을 이용하여 유의수준 .05에서 실시하였다. 결과: 나사의 풀림 토크값의 평균은 7.9 Ncm (1군)과 8.1 Ncm (2군)이었으며, 4개 나사의 풀림 토크값 중 최소값인 최소 풀림 토크값의 평균은 6.1 Ncm (1군)과 6.5 Ncm (2군)이었다. 나사의 풀림 토크값은 두 군 간에 통계적으로 유의할 만한 차이가 없었고, 조인 순서와 위치가 서로 다른 4개의 나사 간의 풀림 토크값도 통계적으로 유의한 차이가 없었다. 최소 풀림 토크값도 두 군 간에 통계적으로 유의할 만한 차이가 없었다. 결론: 다수의 외부 육각 임플란트에 의해 지지되는 보철물에서, 나사의 풀림 토크값과 최소 풀림 토크값은 비연결 인상법과 연결 인상법에 의해 얻어진 모형 간에 차이가 없어, 나사 결합부 안정성에 차이가 없는 것으로 판단된다.