• Title/Summary/Keyword: Acromioclavicular joint fracture

Search Result 20, Processing Time 0.03 seconds

In Vivo Three-dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.174-174
    • /
    • 2009
  • The acromioclavicular-hook-plate is one of the surgical treatments for distal clavicle fracture and traumatic acromioclavicular (AC) joint dislocation. Although this procedure can obtain rigid and accurate anatomical reduction of the AC joint, secondary widening of the hook-hole in the acromion is often seen during postoperative follow-up. This complication is owing to the high-degree of mobility of the AC joint. Therefore, it is important to evaluate the effect on these complications due to the position of the hook-hole. The purpose of the present study is to investigate three-dimensionally the effect due to the position of the hook-hole during arm abduction motion. We studied in vivo and three-dimensional kinematics of the normal shoulder joint with use of a markerless bone-registration technique. Magnetic resonance images of 14 shoulders of 7 healthy volunteers were acquired in 7 positions between $0^{\circ}$ and $180^{\circ}$ of abduction. We created three-dimensional computer models of the bones and the acromioclavicular-hook-plate. Based on the three-dimensional kinematics data, we simulated the widening of the hook-hole each different positioning of the hook-hole. The widths of the hook-holes almost linearly increased. And these widths significantly increased, when we put the hook-hole on the acromion from AC joint to 20 mm and 25 mm posterior position.

  • PDF

A Novel Fluoroscopic View for Positioning the AO Clavicle Hook Plate Decreases Its Associated in situ Complications

  • Hyun, Yoon-Suk;Kim, Gab-Lae;Choi, Sang-Min;Shin, Woo-Jin;Seo, Dong-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 2016
  • Background: The goal of this study was to evaluate whether a modified fluoroscopic technique for positioning a hook plate affected the clinical results of treating Neer type II distal clavicle fractures and Rockwood type V acromioclavicular (AC) joint separations with this device. Methods: The study was a retrospective consecutive case series with data analysis. Sixty-four patients with a Neer type II distal clavicle fracture or a Rockwood type V AC joint injury treated between March 2009 and June 2013 were divided into 2 groups: traditional fluoroscopic technique (traditional view, 31 patients) or modified fluoroscopic technique ('hook' view, 33 patients). A visual analogue scale (VAS) score, the modified University of California-Los Angeles (UCLA) shoulder scale score, and radiographic osteolysis were the main outcome measures. Results: The traditional group included a significantly larger number of patients with acromial osteolysis than the hook view group: 23 patients (74.2%) vs. 11 patients (33.3%), respectively (p=0.01). Before plate removal, the hook group reported less pain and higher UCLA shoulder scale scores than the traditional group: average VAS score, 1.55 vs. 2.26, respectively; average UCLA score, 30.88 vs. 27.06, respectively. However, there was no significant difference after plate removal. Conclusions: The hook view allows more accurate bending of the hook plate around the contour of the acromion, resulting in decreased osteolysis, decreased pain, and better function with the plate in situ.

Percutaneus Cerclage Wiring in Distal Clavicle Fracture Type 2a - One Case Report - (원위 쇄골 골절 2a 형에서의 경피적 환상 강선 고정술 -1례 보고-)

  • Kim, Jae-Hwa;Lee, Soon-Chul;Cho, Duck-Yun;Yoon, Hyung-Ku;Lee, Yoon-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.124-129
    • /
    • 2006
  • Distal clavicular fracture frequently requires operative treatment due to high rate of non-union. The operative technique includes the tension band wiring, K- wire fixation, and cerclage wiring etc. Each method has disadvantages somewhat like pin migration or acromioclavicular joint injury and so on. For the distal clavicular fracture type 2a, because of its oblique fracture line, the cerclage wiring is suitable. We performed the cerclage wiring percutaneously under minimal incision without injury to periosteum for the patient who had the distal clavicular fracture type 2a, and the result was favorable.

Internal Fixation for Isolated Posterolateral Fracture of the Acromion - A Case Report - (단독 후외측 견봉 골절에 대한 내고정술 - 증례 보고 -)

  • Kwon, Young-Ho;Jung, Gu-Hee;Cha, Sang-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2008
  • Isolated acromial fracture is not common and it frequently accompanies fractures to the coracoid process and glenoid bone and also injuries to the acromioclavicular joint. Furthermore, most of these combined acromial fractures have minimal displacement, which needs no additional treatment other than protection for a certain period of time. We have experienced a case of isolated fracture of the posterolateral angle of the acromion, which we reduced and fixated using K-wire and cannulated screws. We report on the technical aspects and clinical results of this reduction and fixation, along with a review of the literature.

Operative Treatment of Ipsilateral Fractures of Clavicle and Scapula (동측에 발생한 쇄골 골절과 견갑골 골절의 수술적 치료)

  • Park Jung Ho;Suh Seung Woo;Park Sang Won;Lee Kwang Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.46-50
    • /
    • 1998
  • The superior shoulder suspensory complex is composed of glenoid fossa, coracoid process, coracoclavicular ligament, distal clavicle, acromioclavicular ligament, acromion. Traumatic double disruptions of this complex lose its suspensory action on the shoulder joint and result in functional loss and deformity. Careful radiologic evaluation and appropriate management are required for injuries to this complex. Ipsilateral fractures of clavicle and scapula create unstable anatomic situation on shoulder joint. Conservative treatment usually fails to achieve good functional recovery due to rotator cuff weakness, nonunion, delayed union, malunion and neurovascular injury. Authors studied the result of operative treatment of ipsilateral clavicle and scapular fractures to prevent such complications. Seven cases were treated with open reduction and internal fixations of clavicle alone or clavicle and scapula simultaneously and followed up for nineteen months(twelve months - thirty-eight months). All but one patient showed good or excellent functional result according to the scoring system of Rowe. Poor result was developed in the case which had brain injury. Rigid fixations of clavicle alone or clavicle and scapular fractures both can achieve stable reduction of the fractures and prevent sequelae. We concluded that operative treatment of ipsilateral fractures of clavicle and scapula is safe and yields predictable good results.

  • PDF

Triple Disruption of the Superior Shoulder Suspensory Complex - Case Report at 5-year-follow up - (상부 견갑 현수 복합체의 3중 붕괴 - 5년 추시 증례 보고 -)

  • Sung, Chang-Meen;Park, Hyung Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.143-147
    • /
    • 2012
  • A triple disruption of the SSSC, an extremely rare injury, has been reported by only a few authors. We present a patient who had sustained a triple disruption of the SSSC: coracoid and scapular spine fractures, and an acromioclavicular joint separation. Treatment consisted of an anatomical restoration of the SSSC, with maintenance of the acromiohumeral and coracohumeral distances; this was achieved by open reduction and internal fixation of the fractures and of the separation. Six months after surgery, the injured shoulder was asymptomatic, with full range of motion. Five years after surgery, at the final follow-up, the function of the SSSC had been restored to the patient's complete satisfaction.

Proposal of Modified Velpeau View as an Alternative Test Method of Velpeau View and the Visual Comparison (Velpeau view의 대체 검사법으로서 modified velpeau view의 제안 및 영상 비교평가)

  • Lee, Jae-Hyun;Kim, Sang-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.323-328
    • /
    • 2010
  • If a patient wearing arm sliding due to shoulder dislocation or fracture is impossible with abduction, the velpeau view is performed instead of superior-inferior axial projection view. However, it aggravates the patient's pain because it is difficult for the patient with dislocation or fracture to pull back the shoulders. Therefore, I suggest a new method of the 'modified velpeau view' that allows patients to lower their heads at examination. In order to investigate the easiness of fixing posture at examination and clinical utility, I conducted a study comparing the bone structures at the velpeau view and those at the modified velpeau view depending on wall-bucky and the patients' leaning forward angle ($30^{\circ},\;45^{\circ},\;60^{\circ}\;and\;75^{\circ}$), with the subjects of 20 velpeau view-prescribed patients amongst who had come to my hospital suspected of dislocation of shoulder or fracture and 30 healthy people from October of 2009 to January of 2010. Department of radiologists and orthopedics specialists evaluated the pictures for scales 0 to 5(best grade) under the given criteria. As a result of comparison in bone structures depending on wall-bucky and the leaning-forward angle in the group of healthy people, the velpeau view and the modified velpeau showed a similar diagnostic utility at $45^{\circ}$ and $60^{\circ}$. The picture evaluation result for proving diagnostic value showed that the anterior and posterior of shoulder heads and the anterior and posterior of glenoid fossa could be observed in the velpeau view; on the other hand, besides these areas acromioclavicular joint and coracoid process could be viewed in the modified velpeau view. This result verified that the modified velpeau view could replace the velpeau view for its diagnostic value as an examination method. This result, moreover, suggests that the modified velpeau view needs to be studied and improved from a variety of perspectives not only for an alternative for patients having troubles with the velpeau view position but also for clinical application of new test method for diagnosis of shoulder disorders other than dislocation of shoulder or fracture.

Concomitant open distal clavicle excision is associated with greater improvement in range of motion without increased risk of acromial stress fracture after reverse total shoulder arthroplasty: a retrospective cohort study

  • Ajay C. Kanakamedala;Dhruv S. Shankar;Neil Gambhir;Matthew R. Boylan;Michael Boin;Matthew G. Alben;Mandeep S. Virk;Young W. Kwon
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.357-365
    • /
    • 2023
  • Background: The purpose of this study was to evaluate the effect of concomitant open distal clavicle excision (DCE) on postoperative clinical outcomes and incidence of acromial and scapular stress fractures (ASFs) in patients with symptomatic acromioclavicular joint osteoarthritis (ACJ OA) undergoing reverse total shoulder arthroplasty (RTSA). Methods: A single-surgeon retrospective cohort study was conducted including patients who underwent primary elective RTSA with or without DCE from 2015 to 2019 with a minimum 6-month follow-up period. Shoulder active range of motion (AROM) and visual analog scale (VAS) pain were recorded preoperatively and postoperatively. ASFs and other adverse events were identified using postoperative notes and/or radiographs. Characteristics and outcomes were compared between the RTSA and RTSA-DCE groups. Results: Forty-six RTSA patients (mean age, 67.9±8.7 years; 60.9% male; mean follow-up, 24.9±16.6 months) and 70 RTSA-DCE patients (mean age, 70.2±8.9 years; 20.0% male; mean follow-up, 22.7±12.9 months) were included. There were no significant intergroup differences in rates of ASF (RTSA, 0.0% vs. RTSA-DCE, 1.4%; P=1.00), stress reactions (RTSA, 8.7% vs. RTSA-DCE, 11.4%; P=0.76), reoperation, revision, or infection (all P>0.05), or in pre-to-postoperative reduction in VAS pain (P=0.17) at latest follow-up. However, the RTSA-DCE group had greater pre-to-postoperative improvement in flexion AROM (RTSA, 43.7°±38.5° vs. RTSA-DCE, 59.5°±33.4°; P=0.03) and internal rotation (IR) AROM (P=0.02) at latest follow-up. Conclusions: Concomitant DCE in RTSA improves shoulder flexion and IR AROM, alleviates shoulder pain, and does not increase the risk of ASFs. Level of evidence: III.

Clinical Comparison of Two Types of Hook Plate in Surgical Treatment of Acromioclavicular Dislocation - AO Hook Plate and Wolter Plate - (견봉 쇄골 관절 탈구의 수술적 치료에서 두 가지 갈고리 금속판의 임상적 비교 - AO Hook Plate와 Wolter Plate -)

  • Choi, Jea-Yeol;Kim, Eugene;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Se-Jin;Lee, Seung-Hee;Lee, Jae-Wook;Choi, Kyu-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • Objective: To evaluate if acromial locking in hook plate is necessary for surgical treatment of acromioclavicular dislocation by compare Wolter plate and AO hook plate. Methods: Seventy one patients who have Rockwood type III to V acromioclavicular joint dislocation treated with AO hook plate and Wolter plate were involved. Among them, 39 patients were treated with Wolter hook plate and 32 patients with AO hook plate. The Constant-Murley score and the range of motion of shoulder joint were measured on postoperative 1st ,$3^{rd}$, $6^{th}$ and $12^{th}$ months, and the radiological complications involving plate and bone were investigated. Results: Constant-Murley score of postoperative one year were $83.2{\pm}6.8$ in AO hook plate group and $85.2{\pm}5.3$ in Wolter plate group without statistical difference (p<0.05). Faster recover of forward elevation and external rotation were examined in Wolter plate group at first and third months after surgery than those of AO hook plate group, but there were no significant difference between after six months or later after surgery. Four cases of loosen or broken screws and one case of pull-out of plate were found in Wolter plate group. Seven cases of subacromial bony erosion and one periprosthetic fracture were found in AO hook plate group. Conclusion: Although clinical outcomes of both two methods were same, no matter if acromial locking system was or not. More radiological complication of plate and bone were found in AO hook plate than that of Wolter plate. However also had disadvantage like larger incision during surgery.

Treatment of Type 2 Distal Clavicle Fracture using Wolter Plate (Wolter 금속판를 이용한 제 2형 원위부 쇄골 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Lee, Kwang-Nam;Lee, Eun-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • Purpose: This study examined the clinical results of the treatment of type 2 distal clavicle fracture with using a Wolter plate. Materials and Methods: Between 2004 and 2007, 16 patient treated for type 2 distal clavicle fracture using a Wolter plate were included in this study. Their average age was 32.6 years and the postoperative mean follow-up period was 22.9 months. The reduction and union were qualified according to the immediate post-operative and final radiographs. The functional outcome was evaluated by Kona's system and the Constant score Results: By Kona's functional evaluation, there were 12 cases with excellent results, 3 cases with good results and 1 case of fair results and the average Constant score was 90. All 16 cases showed bony union. As complications, there was 1 case in which the protruded hook of the plate could be palpated at the skin, and 1 case showed an acromial fracture, but all the cases dispalyed successful bony union and there was no acromioclavicular joint arthritis, infection or any other complications. Conclusion: Wolter plate fixation for type 2 distal clavicle fracture is a reliable surgical method for satisfactory reduction and rigid fixation, a lower incidence of nonunion and excellent clinical result.