• Title/Summary/Keyword: Acquisition time reduction

Search Result 89, Processing Time 0.024 seconds

RESEARCH OF COMMUNICATION SCHEDULING BETWEEN COMPUTER I/O AND S/W FOR ACQUISITION OF SATELLITE SENSORED DATA

  • Koo, Cheol-Hea;Park, Su-Hyun;Kang, Soo-Yeon;Yang, Koon-Ho;Choi, Sung-Bong
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.196-199
    • /
    • 2006
  • Various communication mechanisms have been developed to acquire a meaningful data from sensors. The key requirement during the sensor data acquisition is determinism and reduction of time dependency. It is a fundermental level of satellite data management for controlling satellite operation software data acquisition from sensors or subsystem. Satellite operation software has various software modules to be operated in addition to data acquisition. Therefore, unnecessary time delay shall be minimized to perform the data acquisition. As the result, interrupt method might be prefered than polling method because the former can decrease the restriction of design during implementation of data acquisition logic. The possible problems while using interrupt method like as interrupt latency caused by delaying of interrupt processing time are analyzed. In this paper, communication mechanism which can be used to interface with satellite computer and subsidary subsystem by using interrupt is presented. As well, time dependency between software scheduling and data acquisition is analyzed.

  • PDF

Studies of process measurement technology for manufacturing advanced nano devices (첨단 나노소자 공정제어용 측정기술 연구)

  • Cho, Yong Jai
    • Vacuum Magazine
    • /
    • v.2 no.3
    • /
    • pp.4-10
    • /
    • 2015
  • We developed a real-time three-polarizer spectroscopic ellipsometer based on a new data acquisition algorithm and a general data reduction (the process of extracting the ellipsometric sample parameters from the Fourier coefficients). The data acquisition algorithm measures Fourier coefficients of radiant flux waveform accurately and precisely. The general data reduction is introduced to represent the analytic functions of the standard uncertainties of the ellipsometric sample parameters, and the extracted theoretical values closely agree with the corresponding experimental data. Our approach can be used for optimization of measurement conditions, instrumentation, simulation, standardization, laboratory accreditation, and metrology.

Two Step Binary Exponential Search Algorithm, for Rapid UWB Timing Acquisition (UWB 신호의 빠른 동기 획득을 위한 두 단계 Binary Exponential 탐색 알고리즘)

  • Lee, Nam-Ki;Choi, Hui-Chul;Park, Sung-Kwon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.285-288
    • /
    • 2005
  • In this paper, we propose a two step Binary Exponential search algorithm for rapid acquisition time of UWB(Ultra Wide Band) signal on UWB communication systems. Previous proposed timing acquisition algorithm is searching whole frame that consist of the number of n Bins to terminate search, however this paper proposed two step Binary Exponential search algorithm can achieve remarkable reduction of UWB signal acquisition time as limiting search group. Proposed search algorithm is consisting of search group establishment step and Bit Reversing of search group establishment step.

  • PDF

Switched-Capacitor Variable Gain Amplifier with Operational Amplifier Preset Technique

  • Cho, Young-Kyun;Jeon, Young-Deuk;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.234-236
    • /
    • 2009
  • We present a novel operational amplifier preset technique for a switched-capacitor circuit to reduce the acquisition time by improving the slewing. The acquisition time of a variable gain amplifier (VGA) using the proposed technique is reduced by 30% compared with a conventional one; therefore, the power consumption of the VGA is decreased. For additional power reduction, a programmable capacitor array scheme is used in the VGA. In the 0.13 ${\mu}m$ CMOS process, the VGA, which consists of three-stages, occupies 0.33 $mm^2$ and dissipates 19.2 mW at 60 MHz with a supply voltage of 1.2 V. The gain range is 36.03 dB, which is controlled by a 10-bit control word with a gain error of ${\pm}0.68$ LSB.

  • PDF

Dual-Cell Combining Detection Method for Reduction of Residual Frequency Offset Influence on Code Acquisition Systems (나머자 옵셋이 부호획득 시스템에 미치는 영향을 줄이기 위한 듀얼셀 결합 검파 알고리즘)

  • Chong, Da-Hae;Lee, Young-Yoon;Yoon, Tae-Ung;Lee, Young-Po;Lee, Myung-Soo;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.715-723
    • /
    • 2009
  • In this paper, we propose a new detection method called dual-cell combining (DCC) detection for the acquisition in time of spread spectrum codes in the presence of residual frequency offset (RFO). When the RFO exists, the correlation peak used for detection during the acquisition process is split into two neighboring peaks with smaller amplitudes, resulting in considerable degradation in the overall acquisition performance of conventional methods. In the DCC detection method, the decision variable for detection is formed by combining two consecutive correlator outputs so that the influence of the reduction in the correlation peak due to the RFO can be alleviated. Numerical results show that the DCC detection method can offer better mean-time-to-synchrouization performance than the conventional method based on the cell-by-cell detection.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Partial Matched Filter for Low Power and Fast Code Acquisition of DSSS-CPFSK Signals

  • Park, Hyung-Chul
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.4 no.3
    • /
    • pp.204-209
    • /
    • 2004
  • A partial matched filter (PMF) for semi-coherent correlation code acquisition of the DSSS-CPFSK signal is proposed. It is a calculation-reduced structure of the hard-limited signal based FIR filter, yet its code acquisition time is equal to that of the hard-limited signal based FIR filter. The PMF eliminates duplicate calculations by utilizing the characteristic that the hard-limited DSSS-CPFSK signal has same value in several consecutive samples. For example, the PMF can achieve about 95% reduction in gate size, as compared to the hard-limited signal based FIR filter, when the modulation index of the DSSS-CPFSK signal is equal to 1.5 and the sample rate is equal to 40 sample/chip.

An effectiveness of multitransmit parallel technique on scan time reduction in hip joint MRI (고관절 자기공명영상 검사 시 multitransmit 기법의 적용에 따른 검사시간 단축의 유용성)

  • Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.103-108
    • /
    • 2016
  • This study examined the effectiveness of the multitransmit parallel technique on the MRI scan time reduction by removing the dielectric effect. The T1 and T2 weighted images of the patients' hip joint were acquired with and without a multitransmit technique. The ROIs were located in the head of femur and iliopsoas muscle. The SNR, CNR and scan time were measured and compared. There was no difference in the images with and without multitransmit. In contrast, the acquisition time was decreased by 42.8% in T1WI and 49.7% in T2WI. In conclusion, this study demonstrated that significant scan time reductions can be accomplished without any differences in the image quality in hip joint MRI by applying the multitransmit parallel technique. Furthermore, the multitranstmit technique is useful in other body parts to resolve the long scan time of an MRI examination.

Architecture Design of PN Code Acquisition for MC-CDMA Systems (MC-CDMA 시스템용 PN 부호 동기획득 구조의 구현)

  • 노정민;이성주;김재석
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.2
    • /
    • pp.117-125
    • /
    • 2003
  • In this paper, we propose a new code acquisition architecture having the features of low complexity and high speed for the MC-CDMA system. The newly designed searching finger has function of the searcher as well as the finger. The searching finger tests the PN code Phase as the searcher during the initial acquisition, and as the finger after the initial acquisition. The proposed system has reduced the average acquisition time of the PN codes to $T_{acq}$/19 in the 20MHz MC-CDMA system with 75% reduction of H/W complexity.y.

Development of Image Processing Technique for Determining Wood Drying Schedules

  • Lee, Hyoung-Woo;Kim, Byung-Nam
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.15-21
    • /
    • 2003
  • Image processing technique was adapted for exploring the more convenient ways to investigate the drying characteristics of wood. The acquisition of information about drying characteristics is indispensable for the development or improvement of dry-kiln schedules. A small internal fan type wood dry kiln was combined with image-processing and data-acquisition systems to monitor continuously the formation of checks and moisture reduction during drying. All the images and data were analyzed to improve or estimate the dry-kiln schedules and predict the drying time which would be required to dry green wood to 10% moisture content in internal fan type kiln. Samples of 20 mm- and 50 mm-thick Metasequoia glyptostrobodies, Paulownia coreana Uyeki, Pinus densiflora Sieb. Et Zucc., Platanus occidentalis L., Quercus acutissima and Robinia pseudo-acacia were used to verify the potentiality of this technique.