Characteristics of Earthquake Responses of a Rectangular Liquid Storage Tanks Subjected to Bi-directional Horizontal Ground Motions (수평 양방향 지반운동이 작용하는 직사각형 액체저장탱크의 지진응답 특성)

  • Lee, Jin Ho;Lee, Se Hyeok
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.1
    • /
    • pp.45-53
    • /
    • 2020
  • Analytical and experimental studies show that the dynamic behavior of liquid storage tanks is significantly influenced by the fluid-structure interaction (FSI). The effects of FSI must be rigorously considered for accurate earthquake analysis and seismic design of liquid storage tanks. In this study, a dynamic analysis of a rectangular liquid storage tank subjected to bi-directional earthquake ground motions is performed and its dynamic characteristics are examined, with the effects of FSI rigorously considered. Hydrodynamic pressure is evaluated using the finite-element approach with acoustic elements and applied to the structure. The responses of the rectangular tank subjected to bi-directional earthquake ground motions are thus obtained. It can be observed that the incident angle of bi-directional horizontal ground motions has significant effects on the dynamic responses of the considered system. Therefore, the characteristics of the system must be considered in its seismic design and performance evaluation.

A Refraction Seismic Survey of Unconsolidated Sediments Adjacent Lake Soyang (굴절파 탐사를 이용한 소양호 주변의 미고결 퇴적물 연구)

  • Hong, Myung-Ho;Kim, Ki-Young
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.4
    • /
    • pp.343-349
    • /
    • 2006
  • In order to study unconsolidated sediments upstream of the Soyang Dam, seismic refraction data were recorded along five profiles of 94 m length. Receiver interval and record length were 2 m and 204 ms, respectively. Recorded data were analyzed using the traveltime tomography and delay-time methods in order to reveal sediment distribution in the investigation site. The acoustic basements are buried at approximately 14 m deep and their thickness shallows to southeast approaching to a hill. On the basement, pre-existing sediments deposited before construction of the Soyang dam lies. This sedimentary layer is composed of paleo-soil and sandy sediments. Above this layer, recent sediments comprise the top layer which is believed to have been deposited since the formation of the dam. Average thickness of this uppermost layer is approximately 1.6 m, which is much thicker than in the downstream.

  • PDF

A Study on the Strength Evaluation of Unidirectional Carbon Fiber Reinforced Plastics by Nondestructive Method (일방성(一方性) 복함재료(複合材料)의 파괴거동(破壞擧動) 및 강도평가(强度評價)에 관(關)한 연구(硏究))

  • Chang, H.K.;Lee, J.S.;Cho, K.S.;Lee, S.H.;Park, E.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.42-47
    • /
    • 1988
  • The off-axis tensile strength of the unidirectional carbon fiber reinforced plastic and the residual strength of impact damaged CFRP were measured and compared with the stress wave factor (SWF) of the specimens. The SWF values were measured to be decreased with the strength reduction in both cases and found to be useful for the nondestructive strength evaluation of unidirectional CFRP. The failure behaviour of the unidirectional CFRP during off-axis tensile testing was also monitored by acoustic emission(AE) method. The AE energy release showed the characteristic feature depending on the off-axis angle and this result was analyzed to be caused by the difference of the expected failure mode depending on the off-axis angle. The failure mode of CFRP was found to be analyzed by investigation of the peak amplitude distribution of AE.

  • PDF

The Efficacy of Coblator in Turbinoplasty

  • Lee, Keun-Cheol;Cho, Jeong-Min;Kim, Seok-Kwun;Lim, Kwang-Ryeol;Lee, Sang-Yun;Park, Su-Seong
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.2
    • /
    • pp.82-88
    • /
    • 2017
  • Background: Turbinate hypertrophy is one of the common causes of chronic nasal obstruction. In principle, therapeutic guidelines recommend medical treatment. Failure to treat turbinate thickening despite drug therapy may indicate the need for surgery. The main aim of this study was to determine the effect of radiofrequency surgery, among various other surgical procedures, on people with both nasal septal deviation and turbinate hypertrophy. Methods: Among people with nasal deviation who visited the subject hospital between July 2008 to July 2014, 21 people with nasal septal deviation and severe turbinate hypertrophy before their surgery had undergone septoplasty with turbinoplasty using radiofrequency combined with septoplasty. The degree of the turbinate's hypertrophy was appraised in all the patients before and after the surgery using the rhinoscopy, and acoustic rhinometry was objectively carried out. The subjective effect of the turbinoplasty using radiofrequency was explored through the visual analog scale (VAS) score. Results: The degree of contraction of the nasal mucosa after the rhinoscopy changed from Grades 3 and 4 (100%) to Grades 1 and 2 (95.2%) and Grades 3 (4.8%). The minimal cross-sectional area significantly increased from $0.44{\pm}0.07$ to $0.70{\pm}0.07cm^2$ (p<0.05). The nasal cavity volume increased from $4.79{\pm}0.49$ to $6.76{\pm}0.55cm^2$ (p<0.05). The subjective symptoms evaluated with VAS score a year after the surgery significantly improved (p<0.05). Conclusion: Turbinoplasty using Coblator with septoplasty is an effective treatment method because it expands nasal cavity, has a low incidence of complications, subjectively improves symptoms, and has short treatment duration.

A Study on the Out-of-Band Rejection Improvement of TFBAR Ladder Filter using On-Wafer Inductors (기판상의 인덕터를 이용한 박막 공진 여파기의 대역 외 저지특성 개선 연구)

  • 김종수;구명권;육종관
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.284-290
    • /
    • 2004
  • In this paper, two types of thin nim bulk acoustic resonator(TFBAR) ladder filters are desisted and fabricated to analyze the effects of on-wafer inductor integration. To suppress the overmode phenomenon a 1 $\mu\textrm{m}$ thick air-gap is fabricated under the TFBAR and aluminum nitride is used for piezoelectric material, while platinum is employed for the top and bottom electrodes. The Tx filter in a duplexer, which usually has a steeper skirt characteristics o the right side of the passband, is designed with four serial and two shunt resonators, namely, a 4/2 stage. Similarly, the Rx filter is devised with a 3/4 stage to create a mirrored image of the Tx filter passband characteristics. Fabricated on-wafer spiral inductors with underpass reveals the Q factor of 5~9 at 2 ㎓. Inductor integrated filters have approximately 10 to 12 ㏈ out-of-band rejection improvement, when compared to the original filters.

Effect of Boron Content and Temperature on Interactions and Electron Transport in BGaN Bulk Ternary Nitride Semiconductors

  • Bouchefra, Yasmina;Sari, Nasr-Eddine Chabane
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • This work takes place in the context of the development of a transport phenomena simulation based on group III nitrides. Gallium and boron nitrides (GaN and BN) are both materials with interesting physical properties; they have a direct band gap and are relatively large compared to other semiconductors. The main objective of this paper is to study the effect of boron content on the electron transport of the ternary compound $B_xGa_{(1-x)}N$ and the effect of the temperature of this alloy at x=50% boron percentage, specifically the piezoelectric, acoustic, and polar optical scatterings as a function of the energy, and the electron energy and drift velocity versus the applied electric field for different boron compositions ($B_xGa_{(1-x)}N$), at various temperatures for $B_{0.5}Ga_{0.5}N$. Monte carlo simulation, was employed and the three valleys of the conduction band (${\Gamma}$, L, X) were considered to be non-parabolic. We focus on the interactions that do not significantly affect the behavior of the electron. Nevertheless, they are introduced to obtain a quantitative description of the electronic dynamics. We find that the form of the velocity-field characteristic changes substantially when the temperature is increased, and a remarkable effect is observed from the boron content in $B_xGa_{(1-x)}N$ alloy and the applied field on the dynamics of holders within the lattice as a result of interaction mechanisms.

Research about Hyperspectral Imaging System for Pre-Clinical testing of Small Animal (소형동물 전임상실험을 위한 하이퍼스펙트럼 영상장비 연구)

  • Lee, kyeong-Hee;Choi, Young-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2208-2213
    • /
    • 2007
  • In this study we have developed a hyperspectrum imaging system for highly sensitive and effective imaging analysis. An optical setup was designed using acoustic optical tunable filter (AOTF) for high sensitive hyperspectrum imaging. Light emitted by mercury lamp gets split in to diffracted and undiffracted beams while passing though AOTF. GFP transfected HEK-293 cell line was used as a model for in vitro imaging analysis. Cells were first, analyzed by fluorescence microscope followed by flow cytometric analysis. Flow cytometric analysis showed 66.31% transfection yield in GFP transfected HEK-293 cells. Various images of GFP transfected HEK-293 cell were grabbed by collecting the diffracted light using a CCD over a dynamic range of frequency of 129-171 MHz with an interval of 3 MHz. Subsequently, for in vivo image analysis of GFP transfected cells in mouse, a whole-body-imaging system was constructed. The blue light of 488 nm wavelength was obtained from a Xenon arc lamp using an appropriate filter and transmitted through an optical cable to a ring illuminator. To check the efficacy of the newly developed whole-body-imaging system, a comparative imaging analysis was performed on a normal mouse in presence and absence of Xenon arc irradiation. The developed hyperspectrum imaging analysis with AOTF showed the highest intensity of green fluorescent protein at 153 MHz of frequency and 494 nm of wavelength. However, the fluorescence intensity remained same as that of the background below 138 MHz (475 nm) and above 162 MHz (532 nm). The mouse images captured using the constructed whole-body-imaging system appeared monochromatic in absence of Xenon arc irradiation and blue when irradiated with Xenon arc lamp. Nevertheless, in either case mouse images appeared clearly.

The Effects of Maternal Heart Sound on the Weight, Physiologic Responses and Behavioral States of Premature Infants (산모의 심장소리가 미숙아의 체중, 생리적 반응 및 행동상태에 미치는 효과)

  • Yeum, Mi-Kyung;Ahn, Young-Mee;Seo, Hwa-Sook;Jun, Yong-Hoon
    • Child Health Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.211-219
    • /
    • 2010
  • Purpose: The study was done to measure the effects of maternal heart sound on body weight, physiologic reactions (heart rate [HR] and cortisol) and behavioral states of preterm infants. Methods: Thirty-five preterm infants were recruited from a neonatal intensive care unit at a university hospital. Institutional Review Board approval and informed consent were obtained. The infants were assigned to an experimental group (n=18) with an auditory stimulation for 7 days of life, a continuous delivery of maternal heart sound using MP3 attached inside the incubator, or to a control (n=17) without any auditory stimulation. The outcome variables, daily variations in weight, HR and behavioral states, and differences in cortisol were analyzed. Results: There were differences in variations of daily weights (F=3.431, p=.011) and in cortisol (t=3.184, p=.006) between groups, but no difference in variations of daily HR (F=0.331, p=.933) and behavioral states (F=1.842, p=.323). Conclusion: The findings support the safety of continuous maternal heart sound as no changes in HR and behavioral states occurred, and the efficacy as weight increased and cortisol decreased. This auditory simulation may lead to more efficient utilization of energy in preterm infants by consistently providing familiar sounds from intrauterine life and blocking noxious sounds from NICU environments.

Evaluation of Structural Performance for Filament Wound Composite Ablative Tubes (필라멘트와인딩된 복합재 내열튜브의 구조 성능 평가)

  • 윤성호;황태경;윤남균;문순일
    • Composites Research
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2002
  • Composite ablative tubes required capabilities of ablative and structural characteristics were fabricated through filament winding technique and several experiments were conducted to evaluate the structural performance of composite ablative tubes. For this purpose, manufacturing procedures were briefly described and then resin digestion method was applied to measure the fiber volume fraction and the void content of composite ablative tubes. The configuration of tensile specimen fur composite ablative tubes with not losing the continuity of reinforced fibers was suggested by evaluating mechanical properties of several types of the specimen with different widths. Also, suitable processing variables for composite ablative tubes were determined by evaluating mechanical properties of several types of the specimen with different processing variables. In addition, acoustic emission signals were obtained during the proof test and could be applicable to study the crack initiation and the damage mode of composite ablative tubes. Finally, the structural reliability of composite ablative tubes could be verified to satisfy design requirements through the proof and burst tests.

Whistle Characteristics of Captive Beluga Whale Delphinapterus leucas (사육 흰고래(Delphinapterus leucas)의 휘슬음 특징)

  • Choi, Seulgi;Yuk, Hyeong jun;Han, Won min;Yoon, Young Geul;Sohn, Hawsun;Lee, Kyunglee;Park, Kyum Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.6
    • /
    • pp.799-805
    • /
    • 2017
  • The whistle sounds of three Beluga whales Delphinapterus leucas were recorded four times, for an hour each time, in 2016 and analyzed to obtain the most stable and basic acoustic characteristics of the whales in captivity. This study investigated the whistle characteristics of beluga whales and the relationship between whistle sounds and behavior to understand the meaning of the whistle sounds. The whistles were classified into six types (flat, ascending, descending, hump, dip, and wavy type) by their frequency contour and shape. The most common type was the ascending type, accounting for>30% of total whistles. The fundamental frequency of whistles was 2.0-8.6 kHz. Four types of behavior were related with the sounds of beluga whales (aggressive, submissive, affiliative, sexual behavior). A flat whistle was the most recorded in the group and an aggressive act was observed in association with the flat whistle. A dip whistle were recorded more when submissive acts were observed.