Measurement of decoupling performance of an multi-layered underwater decoupling material (다층구조 수중 방음재의 디커플링성능 측정방법에 대한 고찰)
-
- Proceedings of the Korean Society for Noise and Vibration Engineering Conference
- /
- 2012.10a
- /
- pp.437-444
- /
- 2012
In this paper, the measurement method of the decoupling performance of a underwater decoupling material is studied. First, the simple vibro-acoustic coupled model of a multi-layered underwater decoupling material attached to a plate is analytically derived using impedance transfer matrix. Two test methods are introduced using the theoretical expression of the simple model. One is based on the ratio of the plate vibration and the radiated pressure under impact excitation of the plate. The other is based on the reciprocity theorem and uses the ratio of the incident pressure and the plate vibration under projector excitation in water. Some measurements are carried out according to the test methods using a pulse tube. The test results show the advantages and disadvantages of two methods. It is also shown that the combination of impact and projector excitation methods may be a useful tool to evaluate the performance of a underwater decoupling material.
A loud speaker-driven zero-c.o.p. thermoacoustic refrigerator where an automotive catalytic converter is utilized as a stack has been fabricated and investigated experimentally. Without any heat exchangers at both ends of stack(and thus with zero c. o. p.), temperatures on the stack are measured and various heat transfer rates are calculated from the measured temperatures. Temperatures on the stack have been also calculated numerically using a finite difference method. The measured temperatures are in fair agreement with the calculated temperatures for lower frequency than 300Hz, however, the former deviates from the latter considerably for higher frequency. Two types of c. o. p. have been defined as appropriate to the experiment. While the nominal c. o. p. is zero(the condition in which the pumped heat flow rate in the pore exactly cancels the axial heat conduction down the stack), the true c. o. p. is found to be about 0.14 for 300Hz from the experiments.
In this paper, an index for the evaluation of a vehicle intake booming noise and intake sound quality were developed through a correlation analysis and a multiple factor regression analysis of objective measurement and subjective evaluation data. At first, an intake orifice noise was measured at the wide-open throttle test condition. And then, an acoustic transfer function between intake orifice noise and interior noise at the steady state condition was estimated. Simultaneously, subjective evaluation was carried out with a 10-scale score by 8 intake noise and vibration expert evaluators. Next, the correlation analysis between the psychoacoustic parameters derived from the measured data and the subjective evaluation was performed. The most critical factor was determined and the corresponding index for intake booming noise and sound quality are obtained from the multiple factor regression method. And, the optimal design of intake system was studied using the booming noise and the sound quality evaluation index for expectation performance of intake system. Conclusively, the optimal designing parameters of intake system from noise level and sound quality whose point of view were extracted by adapting comparative weighting between the booming noise and sound quality evaluation index, which optimized the process. These work could be represented guideline to system engineers, designers and test engineers about optimization procedure of system performance by considering both of noise level and sound quality.
Multipath makes clear message transfer difficult in the underwater communication. To solve this problem, we propose a new method producing proper MFSP (Modulation Frequency Shift Period) which could be obtained by calculating time delay caused by different path from a transmitter to a receiver. At the transmitter end, messages were divided according to the size of the MFSP and transmitted accordingly alternating Frequency. At the receiver end, the received messages were demodulated in order to recover the original message by the adaptive BISMO algorithm which is constructed at the algorithm design stage. Adaptive MFSP and estimated BER (Bit Error Rate) were calculated through simulation test.
When the heat release and acoustic pressure fluctuations are generated in the combustor by irregular combustion, these fluctuations affect the mass flow rate of the propellants injected through the injectors. Also, the variations of the mass flow rate by these fluctuations again bring about irregular combustion and furthermore that is related with combustion instability. Therefore, it is very important to identify the mass variation for the pressure fluctuation on the injector and to investigate its transfer function. So, we first have studied quantifying the variation of mass flow rate generated in simplex swirl injector by injection pressure fluctuation. To acquire the transient mass flow rate in orifice with time, we have tried to measure of the flow axial velocity and liquid film thickness in orifice. The axial velocity is acquired through theoretical approach after measuring the pressure in orifice and the flow area in the orifice is measured by electric conductance method. As results, mass flow rate calculated by axial velocity and liquid film thickness measuring in orifice accorded with mass flow rate acquired by direct measuring method in the small error range within 1 percents in steady state and within 6 percents as average mass flow rate in pulsated state. Hence this method can be used to measure the mass flow rate not only in steady state but also in unsteady state because the mass flow rate in the orifice can acquire with time and this method shows very high accuracy based on the experimental results.
High-speed vehicles are subjected to complex loads, such as acoustic pressure from the engine at launch and aerodynamic heating and aerodynamic pressure during flight. A thermal protection system panel is required to protect internal systems such as the fuel tank of the vehicle from the external environment. This study defines analytical models for heat transfer and thermal structure characteristics of the thermal protection system panel. Furthermore, the study performed parameters analysis to achieve the thermal structural integrity and to make it lighter.
The problem of determining the discharge rates of gases from pressurized vessels through pressure relief devices was dealt with comprehensively. First, starting from basic fluid flow equations, detailed modeling procedures were presented for isentropic nozzle flows and frictional flows in a pipe, respectively. Meanwhile, physical explanations were given to choking phenomena in terms of the acoustic velocity, elucidating the widespread use of Mach numbers in gas flow models. Frictional flows in a pipe were classified into adiabatic, isothermal, and general flows according to the heat transfer situation around the pipe, but the adiabatic flow model was recommended suitable for gas discharge through pressure relief devices. Next, for the isentropic nozzle flow followed by adiabatic frictional flow in the pipe, two equations were established for two unknowns that consist of the Mach numbers at the inlet and outlet of the pipe, respectively. The relationship among the ratio of downstream reservoir pressure to upstream pressure, mass flux, and total frictional loss coefficient was shown in various forms of MATLAB 2-D plot, 3-D surface plot and contour plot. Then, the profiles of gas properties and velocity in the pipe section were traced. A method to quantify the relationship among the pressure head, velocity head, and total friction loss was presented, and was used in inferring that the rapid increase in gas velocity in the region approaching the choked flow at the pipe outlet is attributed to the conversion of internal energy to kinetic energy. Finally, the Levenspiel chart reproduced in this work was compared with the Lapple chart used in API 521 Standatd.
According to developments of digital signal processing, 3D sound come into focus on multimedia systems. Many studies on 3d sound have proposed lots of clues to create realistic sounds. But these clues are only focused on binaural systems which two ears are normal. If we make the 3d sound using those clues at monaural systems, the performance goes down dramatically. In order to use the clues for monaural systems, we have studies algorithms such as duplex theory. In duplex theory, the sounds that we listen are affected by human's body, pinna and shoulder. So, we can enhance sound localization performances using its characteristics. In this paper, we propose a new method to use psychoacoustic theory that creates realistic 3D audio at monaural systems. To improve 3d sound, we calculate the excitation energy rates of each symmetric HRTF and extract the weights in each bark range. Finally, they are applied to emphasize the characteristics related to each direction. Informal listening tests show that the proposed method improves sound localization performances much better than the conventional methods.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70