• Title/Summary/Keyword: Acetabular revision

Search Result 5, Processing Time 0.015 seconds

The Dome Technique for Managing Massive Anterosuperior Medial Acetabular Bone Loss in Revision Total Hip Arthroplasty: Short-Term Outcomes

  • Tyler J. Humphrey;Colin M. Baker;Paul M. Courtney;Wayne G. Paprosky;Hany S. Bedair;Neil P. Sheth;Christopher M. Melnic
    • Hip & pelvis
    • /
    • v.35 no.2
    • /
    • pp.122-132
    • /
    • 2023
  • Purpose: The dome technique is a technique used in performance of revision total hip arthroplasty (THA) involving intraoperative joining of two porous metal acetabular augments to fill a massive anterosuperior medial acetabular bone defect. While excellent outcomes were achieved using this surgical technique in a series of three cases, short-term results have not been reported. We hypothesized that excellent short-term clinical and patient reported outcomes could be achieved with use of the dome technique. Materials and Methods: A multicenter case series was conducted for evaluation of patients who underwent revision THA using the dome technique for management of Paprosky 3B anterosuperior medial acetabular bone loss from 2013-2019 with a minimum clinical follow-up period of two years. Twelve cases in 12 patients were identified. Baseline demographics, intraoperative variables, surgical outcomes, and patient reported outcomes were acquired. Results: The implant survivorship was 91% with component failure requiring re-revision in only one patient at a mean follow-up period of 36.2 months (range, 24-72 months). Three patients (25.0%) experienced complications, including re-revision for component failure, inter-prosthetic dual-mobility dissociation, and periprosthetic joint infection. Of seven patients who completed the HOOS, JR (hip disability and osteoarthritis outcome score, joint replacement) survey, five patients showed improvement. Conclusion: Excellent outcomes can be achieved using the dome technique for management of massive anterosuperior medial acetabular defects in revision THA with survivorship of 91% at a mean follow-up period of three years. Conduct of future studies will be required in order to evaluate mid- to long-term outcomes for this technique.

Reduction of the Femoral Head First, and Assembly of the MUTARS® Device in Case of Impossible Reduction during Total Hip Arthroplasty

  • Jee Young Lee;Ye Jun Lee;Gyu Min Kong
    • Hip & pelvis
    • /
    • v.35 no.4
    • /
    • pp.277-280
    • /
    • 2023
  • Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS®. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

A Study on Computer Aided Surgical Simulation Method for Total Hip Arthroplasty (컴퓨터 응용 인공고관절 모사 시술 방법 연구)

  • Kim Sang Hoo;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.455-464
    • /
    • 2004
  • Total hip arthroplasty(THA) considerably depends on high-experienced doctors because of high difficulty of the operation. Selection of acetabular cup's and femoral implant's position is closely related with success or failure of THA. Nevertheless the selection has usually depended on doctor's eye measurement, which makes the position accuracy of artificial joint lower after THA, often resulting in revision of THA. The present study determined a method to select accurately the position of acetabular cup and femoral implant through surgical simulation with 3D characteristic geometrical information of patient's pelvis and femur. We examined the change of femoral anteversion angle and neck-shaft angle accompanied by the change of acetabular cup's position and the insertion position of femoral implant. As result of analyzing geometrical information through different surgical simulations, we found that it was possible to select the accurate position of acetabular cup and femoral implant. It is expected to help doctors get experienced in THA operation through repetitive surgical simulations using the method suggested in the study.

Pseudotumor and Subsequent Implant Loosening as a Complication of Revision Total Hip Arthroplasty with Ceramic-on-Metal Bearing: A Case Report

  • Naik, Lokesh Gudda;Shon, Won Yong;Clarke, I.C.;Moon, Jun-Gyu;Mukund, Piyush;Kim, Sang-Min
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2018
  • Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.

Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly

  • Mathias van den Broek;Kris Govaers
    • Hip & pelvis
    • /
    • v.35 no.1
    • /
    • pp.54-61
    • /
    • 2023
  • Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, three, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.