The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images (PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가)

  • Han, Dong Chan;Hong, Gun Chul;Choi, Choon ki;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of $^{18}F-FDG$. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.67{\pm}0.06g/mL$ and $0.65{\pm}0.06g/mL$, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.32{\pm}0.08g/mL$ and $0.56{\pm}0.12g/mL$, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

  • PDF

Habitat Distribution Change Prediction of Asiatic Black Bears (Ursus thibetanus) Using Maxent Modeling Approach (Maxent 모델을 이용한 반달가슴곰의 서식지 분포변화 예측)

  • Kim, Tae-Geun;Yang, DooHa;Cho, YoungHo;Song, Kyo-Hong;Oh, Jang-Geun
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.197-207
    • /
    • 2016
  • This study aims at providing basic data to objectively evaluate the areas suitable for reintroduction of the species of Asiatic black bear (Ursus thibetanus) in order to effectively preserve the Asiatic black bears in the Korean protection areas including national parks, and for the species restoration success. To this end, this study predicted the potential habitats in East Asia, Southeast Asia and India, where there are the records of Asiatic black bears' appearances using the Maxent model and environmental variables related with climate, topography, road and land use. In addition, this study evaluated the effects of the relevant climate and environmental variables. This study also analyzed inhabitation range area suitable for Asiatic black and geographic change according to future climate change. As for the judgment accuracy of the Maxent model widely utilized for habitat distribution research of wildlife for preservation, AUC value was calculated as 0.893 (sd=0.121). This was useful in predicting Asiatic black bears' potential habitat and evaluate the habitat change characteristics according to future climate change. Compare to the distribution map of Asiatic black bears evaluated by IUCN, Habitat suitability by the Maxent model were regionally diverse in extant areas and low in the extinct areas from IUCN map. This can be the result reflecting the regional difference in the environmental conditions where Asiatic black bears inhabit. As for the environment affecting the potential habitat distribution of Asiatic black bears, inhabitation rate was the highest, according to land coverage type, compared to climate, topography and artificial factors like distance from road. Especially, the area of deciduous broadleaf forest was predicted to be preferred, in comparison with other land coverage types. Annual mean precipitation and the precipitation during the driest period were projected to affect more than temperature's annual range, and the inhabitation possibility was higher, as distance was farther from road. The reason is that Asiatic black bears are conjectured to prefer more stable area without human's intervention, as well as prey resource. The inhabitation range was predicted to be expanded gradually to the southern part of India, China's southeast coast and adjacent inland area, and Vietnam, Laos and Malaysia in the eastern coastal areas of Southeast Asia. The following areas are forecast to be the core areas, where Asiatic black bears can inhabit in the Asian region: Jeonnam, Jeonbuk and Gangwon areas in South Korea, Kyushu, Chugoku, Shikoku, Chubu, Kanto and Tohoku's border area in Japan, and Jiangxi, Zhejiang and Fujian border area in China. This study is expected to be used as basic data for the preservation and efficient management of Asiatic black bear's habitat, artificially introduced individual bear's release area selection, and the management of collision zones with humans.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Object-based Building Change Detection Using Azimuth and Elevation Angles of Sun and Platform in the Multi-sensor Images (태양과 플랫폼의 방위각 및 고도각을 이용한 이종 센서 영상에서의 객체기반 건물 변화탐지)

  • Jung, Sejung;Park, Jueon;Lee, Won Hee;Han, Youkyung
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_2
    • /
    • pp.989-1006
    • /
    • 2020
  • Building change monitoring based on building detection is one of the most important fields in terms of monitoring artificial structures using high-resolution multi-temporal images such as CAS500-1 and 2, which are scheduled to be launched. However, not only the various shapes and sizes of buildings located on the surface of the Earth, but also the shadows or trees around them make it difficult to detect the buildings accurately. Also, a large number of misdetection are caused by relief displacement according to the azimuth and elevation angles of the platform. In this study, object-based building detection was performed using the azimuth angle of the Sun and the corresponding main direction of shadows to improve the results of building change detection. After that, the platform's azimuth and elevation angles were used to detect changed buildings. The object-based segmentation was performed on a high-resolution imagery, and then shadow objects were classified through the shadow intensity, and feature information such as rectangular fit, Gray-Level Co-occurrence Matrix (GLCM) homogeneity and area of each object were calculated for building candidate detection. Then, the final buildings were detected using the direction and distance relationship between the center of building candidate object and its shadow according to the azimuth angle of the Sun. A total of three methods were proposed for the building change detection between building objects detected in each image: simple overlay between objects, comparison of the object sizes according to the elevation angle of the platform, and consideration of direction between objects according to the azimuth angle of the platform. In this study, residential area was selected as study area using high-resolution imagery acquired from KOMPSAT-3 and Unmanned Aerial Vehicle (UAV). Experimental results have shown that F1-scores of building detection results detected using feature information were 0.488 and 0.696 respectively in KOMPSAT-3 image and UAV image, whereas F1-scores of building detection results considering shadows were 0.876 and 0.867, respectively, indicating that the accuracy of building detection method considering shadows is higher. Also among the three proposed building change detection methods, the F1-score of the consideration of direction between objects according to the azimuth angles was the highest at 0.891.

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

How to Determine the Moving Target Exactly Considering Target Size and Respiratory Motion: A Phantom Study (종양의 움직임과 호흡주기에 따른 체적 변화에 대한 연구: 팬텀 Study)

  • Kim, Min-Su;Back, Geum-Mun;Kim, Dae-Sup;Kang, Tae-Yeong;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.145-153
    • /
    • 2010
  • Purpose: To accurately define internal target volume (ITV) for treatment of moving target considering tumor size and respiratory motion, we quantitatively investigated volume of target volume delineated on CT images from helical CT and 4D CT scans. Materials and Methods: CT images for a 1D moving phantom with diameters of 1.5, 3, and 6 cm, acryl spheres were acquired using a LightSpeed $RT^{16}CT$ simulator. To analyze effect of tumor motion on target delineation, the CT image of the phantoms with various moving distances of 1~4 cm, and respiratory periods of 3~6 seconds, were acquired. For investigating the accuracy of the target trajectory, volume ratio of the target volumes delineated on CT images to expected volumes calculated with diameters of spherical phantom and moving distance were compared. Results: Ratio$_{helical}$ for the diameter of 1, 5, 3, and 6 cm targets were $32{\pm}14%$, $45{\pm}14%$, and $58{\pm}13%$, respectively, in the all cases. As to 4DCT, RatioMIP were $98{\pm}8%$, $97{\pm}5%$, and $95{\pm}1%$, respectively. Conclusion: The target volumes delineated on MIP images well represented the target trajectory, in comparison to those from helical CT. Target volume delineation on MIP images might be reasonable especially for treatment of early stage lung cancer, with meticulous attention to small size target, large respiratory motion, and fast breathing.

  • PDF

Net Primary Production Changes over Korea and Climate Factors (위성영상으로 분석한 장기간 남한지역 순 일차생산량 변화: 기후인자의 영향)

  • Hong, Ji-Youn;Shim, Chang-Sub;Lee, Moung-Jin;Baek, Gyoung-Hye;Song, Won-Kyong;Jeon, Seong-Woo;Park, Yong-Ha
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.4
    • /
    • pp.467-480
    • /
    • 2011
  • Spatial and temporal variabilities of NPP(Net Primary Production) retrieved from two satellite instruments, AVHRR(Advanced Very High Resolution Radiometer, 1981-2000) and MODIS(MODerate-resolution Imaging Spectroradiometer, 2000-2006), were investigated. The range of mean NPP from A VHRR and MODIS were estimated to be 894-1068 $g{\cdot}C/m^2$/yr and 610-694.90 $g{\cdot}C/m^2$/yr, respectively. The discrepancy of NPP between the two instruments is about 325 $g{\cdot}C/m^2$/yr, and MODIS product is generally closer to the ground measurement than AVHRR despite the limitation in direct comparison such as spatial resolution and vegetation classification. The higher NPP values over South Korea are related to the regions with higher biomass (e.g., mountains) and higher annual temperature. The interannual NPP trends from the two satellite products were computed, and both mean annual trends show continuous NPP increase; 2.14 $g{\cdot}C/m^2$/yr from AVHRR(1981-2000) and 6.08 $g{\cdot}C/m^2$/yr from MODIS (2000-2006) over South Korea. Specifically, the higher increasing trends over the Southwestern region are likely due to the increasing productivity of crop fields from sufficient irrigation and fertilizer use. The retrieved NPP shows a closer relationship between monthly temperature and precipitation, which results in maximum correlation during summer monsoons. The difference in the detection wavelength and model schemes during the retrieval can make a significant difference in the satellite products, and a better accuracy in the meterological and land use data and modeling applications will be necessary to improve the satellite-based NPP data.

Comparison of $^{18}F$ FDG-PET and CT/MRI for the Diagnosis of Cervical Lymph Node Metastasis in Head and Neck Cancer: A Level-by-Level Based Study (두경부암 환자에서 경부 림프절 전이에 대한 $^{18}F$ FDG-PET과 CT/MRI의 진단적 정확도 비교: 림프절군에 따른 연구)

  • Yang, Yoo-Jung;Kim, Jae-Seung;Kim, Sang-Yun;Lee, Ho-Gyu;Nam, Soon-Yul;Choi, Seung-Ho;Ryu, Jin-Sook;Yeo, Jeong-Seok;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.1
    • /
    • pp.52-61
    • /
    • 2004
  • Purpose: Cervical lymph node metastasis is the most important factor of the prognosis and therapeutic planning in head and neck cancer. With increasing interest of minimally invasive neck surgery, more accurate preoperative assessment of cervical lymph node becomes more essential. We evaluated the diagnostic accuracy of $^{18}F$ FDG-PET in the assessment of lymph node metastasis in patients with primary head and neck cancer and compared the results with those of CT/MRI. Materials and Methods: Thirty-two patients (M/F=27/5, $56{\pm}10yr$) with biopsy proven head and neck cancer (16 supraglottic cancer, 9 tongue cancer, 7 others) underwent FDG-PET and CT/MRI (25/7) within 1 month before neck dissection. Based on lymph node level, the diagnostic sensitivity and specificity of FDG PET and CT/MRI for the metastasis of cervical lymph node were compared. Results: Of 153 lymph node levels dissected in 32 patients, 32 lymph node levels of 19 patients were positive for metastasis by histopatholologic examination. The overall sensitivity and specificity of FDG-PET were 88% (28/32) and 93% (113/121), whereas those of CT/MRI were 56% (18/32) (p=0.002) and 92% (112/121), respectively. The diagnostic sensitivity and specificity of FDG-PET were different according to location of lymph node levels, and those of ipsilateral level 11 were lower than those of other levels. Conclusion: FDG-PET is more sensitive in detecting metastatic cervical lymph node in head and neck cancer than CT/MRI. FDG-PET might be useful in guiding the extent of neck dissection.

Embryo Transfer with Sex-Determined Hanwoo Embryos Produced by In-vitro Fertilization (성감별된 한우 체외수정란의 수정란 이식)

  • 김용준;이창민;정구남;이해리;조성우;김용수;신동수;홍유미;유일정
    • Journal of Embryo Transfer
    • /
    • v.18 no.2
    • /
    • pp.97-108
    • /
    • 2003
  • In-vitro fertilized Hanwoo embryos were biopsied for sex determination by PCR. Biopsied embryos were incubated for 1∼2 hours for the recovery. Those sexed Hanwoo embryos were transferred to 49 Hanwoo and 16 Holstein recipients from February 2000 to February 2001. Of 65 recipients, 14 cows(12 Hanwoo and 2 Holstein) delivered the same offspring as sex-determined by PCR, therefore the conception rate was 21.5%. 1. Total 65 embryos(male 35, female 30) were transferred to recipients, and 14 calves (male 6, female 8) were delivered. In comparison between sex by PCR method and sex of calves born after embryo transfer, the accuracy of sex determination was 100.0%. 2. The conception rate after transfer with biopsied embryo between Hanwoo and Holstein was 24.5% and 12.5% 3. The conception rate after transfer with biopsied embryo between fresh and frozen-thawed embryos was 23.5% and 14.3%. 4. The conception rate according to the season when embryo was transferred was 11.8, 29.4, 23.5 and 20.0% for spring, summer, autumn and winter, respectively. 5. The conception rate according to embryo quality after biopsy was 41.7, 30.0 and 0.0% for excellent, good and fair quality. 6. The conception rate according to thickness of uterine horn was 71.4, 18.9, 11.8 and 0.0% for 0, +, ++ and +++ thickness. 7. The conception rate according to the site in the uterine hem where embryo was put was 30.0, 20.0 and 10.0% for cranial, mid, and caudal part of uterine horn. 8. The conception rate according to the quality of corpus luteum ipsilateral to the uterine horn where embryos was transferred was 41.2, 14.3 and 15.4% for excellent, good and fair quality. 9. The conception rate according to the time required for embryo transfer was 18.2, 30.0, 30.0, 0.0 and 25.0% for 10, 15, 20, 25 and 30 minutes. 10. The conception rate according to parity of recipients was 26.5, 19.1, 14.3 and 0.0% for the primiparous, the 2nd parous, the 3rd parous and the 4th parous recipients. These results indicated that fresh embryos are more demanded than frozen-thawed embryos for good conception rate in embryo transfer with biopsied-sexed embryo. Also, it was indicated that we should consider embryo-recovering condition, recipient's uterine thickness, transfer site in uterine horn, quality of corpus luteum, time required for transfer and parity of recipient to achieve good conception rate in ET with biopsied-sexed embryos.