• Title/Summary/Keyword: Accuracy comparison

Search Result 3,230, Processing Time 0.021 seconds

Accuracy Evaluation and Terrain Model Creation of Urban Space using Unmanned Aerial Vehicle System (무인항공시스템을 이용한 도시공간 지형모델 생성 및 정확도 평가)

  • Do, Myung-Sik;Lim, Eon-taek;Chae, Jung-hwan;Kim, Sung-hun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.5
    • /
    • pp.117-127
    • /
    • 2018
  • The author tried to propose the orthographic and DTM (digital terrain model) creation and evaluate the accuracy for an university campus using UAV (unmanned aerial vehicle) system. Most previous studies used GPS-based data, but in this paper, the observations of triangulation level measurements was used for comparison of accuracy. Accuracy analysis results showed that the operational requirements for aerial photographic standards are satisfied in all scenaries. The author confirmed availability in aviation photo measurements and applications using UAV (Drone). In order to create a sophisticated DTM and contour, we need to eliminate interference from building, trees, and artificial objects. The results of this study are expected to be used as the basis for future studies in the creation of DTM and the accuracy assessments using Drone.

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

The Effects of Accuracy on Skill Level and Eye-Tracking Type in Golf Putting (숙련도와 시선형태가 골프퍼팅의 정확성에 미치는 영향)

  • Woo, Byung-Hoon;Kim, Chang-Won;Park, Yang-Sun;Lee, Kun-Chun;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.729-738
    • /
    • 2009
  • The purpose of this study was to analyze the impact accuracy and kinematic parameters of skill level and eye-tracking type during putting strokes. For comparison, five elite golfers and five novice golfers participated in this study. Three-dimensional kinematic data were collected for each subject while 10 putting trials were performed for each skill level and eye-tracking type. The APAS system was used to compute the impact accuracy and kinematic parameters of putter heads. The putting stroke was divided into three phases: back swing, downswing, and follow-through. The findings indicated that significant differences were found in skill level as it affected the rate of success. For impact accuracy and the displacement of putter heads, a significant difference was found for the skill level, particularly in backs-wing and follow-through. In addition, the displacement of the putter head had a greater influence on stroke accuracy than on velocity.

Comparisons of Imputation Methods for Wave Nonresponse in Panel Surveys (패널조사 웨이브 무응답의 대체방법 비교)

  • Kim, Kyu-Seong;Park, In-Ho
    • Survey Research
    • /
    • v.11 no.1
    • /
    • pp.1-18
    • /
    • 2010
  • We compare various imputation methods for compensating wave nonresponse that are commonly adopted in many panel surveys. Unlike the cross-sectional survey, the panel survey is involved a time-effect in nonresponse in a sense that nonresponse may happen for some but not all waves. Thus, responses in neighboring waves can be used as powerful predictors for imputing wave nonresponse such as in longitudinal regression imputation, carry-over imputation, nearest neighborhood regression imputation and row-column imputation method. For comparison, we carry out a simulation study on a few income data from the Korean Welfare Panel Study based on two performance criteria: predictive accuracy and estimation accuracy. Our simulation shows that the ratio and row-column imputation methods are much more effective in terms of both criteria. Regression, longitudinal regression and carry-over imputation methods performed better in predictive accuracy, but less in estimation accuracy. On the other hand, nearest neighborhood, nearest neighbor regression and hot-deck imputation show higher performance in estimation accuracy but lower predictive accuracy. Finally, the mean imputation shows much lower performance in both criteria.

  • PDF

The Accuracy of Hysterosalpingography for Evaluating Female Infertility (불임 검사시 자궁난관 조영술의 진단 정확도)

  • Park, Joon Cheol;Kim, Jong In;Rhee, Jeong Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.32 no.3
    • /
    • pp.223-230
    • /
    • 2005
  • Objective: This study was performed to evaluate the accuracy of hysterosalpingography (HSG) for evaluating female infertility patients by comparison with hysteroscopic and laparoscopic examination. Methods and Material: Total 219 infertile patients were retrospectively analyzed between January 1, 2002 and December 31, 2003. Ninety seven patients (44.3%) were primary infertility, 122 patients (55.7%) were secondary infertility. We performed hysteroscopic and laparoscopic examination on next cycle when HSG revealed any abnormal finding, and 3~6 cycles later if HSG was normal. Results: The accuracy of HSG was 65.2% compared with hysteroscopic examination (sensitivity 88.4%, specificity 46.4%, false positive rate 53.6%, false negative rate 11.6%). The most common abnormal finding of hysteroscopy was uterine synechia (67.4%) followed by endometrial polyp, uterine anomaly (e.g. uterine septum), endometrial hyperplasia. Compared with laparoscopic examination, the accuracy of HSG was 76.9% (sensitivity 98.9%, specificity 70.6%, +LR 3.36, -LR 0.02). The positive predictive value of normal patent tube was excellent (99.6%) but that of proximal tubal blockage was only 46.7%. The unilateral tubal obstruction of HSG was poor accuracy (+LR 3.85 -LR 0.68) and 70% of those was patent by laparoscopic examination. Laparoscopic examination also revealed that 53% of patients had peritubal adhesion and 37% of patients has additional pelvic findings, especially endometriosis. Among the patients had normal HSG, 53.5% patients with normal ultrasonography was diagnosed endometriosis (25.6% of them had endometriosis stage I-II). Conclusion: Normal HSG shows a high negative predictive value. Nevertheless, the incidence of associated pelvic disease in the normal HSG group is high enough to warrant diagnostic laparoscopy if nonsurgical treatment is unsuccessful. Because HSG has poor accuracy in predicting distal tubal blockage and peritubal adhesion, and poor positive predictive value of proximal tubal blockage, laparoscopic examination could be considered in abnormal HSG group.

Subtractive versus additive indirect manufacturing techniques of digitally designed partial dentures

  • Snosi, Ahmed Mamdouh;Lotfy, Shaimaa Mohamed;Thabet, Yasmine Galaleldin;Sabet, Marwa Ezzat;Rizk, Fardos Nabil
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.5
    • /
    • pp.327-332
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of digitally designed removable partial denture (RPD) frameworks, constructed by additive and subtractive methods castable resin patterns, using comparative 3D analysis. MATERIALS AND METHODS. A Kennedy class III mod. 1 educational maxillary model was used in this study. The cast was scanned after modification, and a removable partial denture framework was digitally designed. Twelve frameworks were constructed. Two groups were defined: Group A: six frameworks were milled with castable resin, then casted by the lost wax technique into Co-Cr frameworks; Group B: six frameworks were printed with castable resin, then casted by the lost wax technique into Co-Cr frameworks. Comparative 3D analysis was used to measure the accuracy of the fabricated frameworks using Geomagic Control X software. Student's t-test was used for comparing data. P value ≤ .05 was considered statistically significant. RESULTS. Regarding the accuracy of the occlusal rests, group A (milled) (0.1417 ± 0.0224) showed significantly higher accuracy than group B (printed) (0.02347 ± 0.0221). The same results were found regarding the 3D comparison of the overall accuracy, in which group A (0.1501 ± 0.0205) was significantly more accurate than group B (0.179 ± 0.0137). CONCLUSION. In indirect fabrication techniques, subtractive manufacturing yields more accurate RPDs than additive manufacturing.

The Effect of Vibration Convergence Prop Exercise on Batting Speed and Batting Accuracy in Elementary School Baseball Players (진동을 융합한 소도구운동이 초등학교 야구선수들의 타격속도와 타격정확도에 미치는 영향)

  • Kim, Yong-Nam;Park, Se-Ju;Jeong, Ho-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.35-41
    • /
    • 2021
  • The purpose of this study was to investigate the effect of prop exercise convergence using vibration on batting speed and batting accuracy in elementary school baseball players. Three times a week for six weeks. The vibration exercise experimental group and the control group were divided into each twenty members. The experimental group performed vibration convergence prop exercise, and the control group performed general exercise. Batting speed and Batting accuracy were measured. The experimental and control groups showed significant differences in the groups of batting speed before and after intervention. There was significant difference between the batting accuracy in the comparison between the experimental group and the control group. Prop convergence vibration exercise may help to improve the batting speed and batting accuracy of elementary school baseball players. In the future, adult and sport injury patient are needed.

Accuracy of genotype imputation based on reference population size and marker density in Hanwoo cattle

  • Lee, DooHo;Kim, Yeongkuk;Chung, Yoonji;Lee, Dongjae;Seo, Dongwon;Choi, Tae Jeong;Lim, Dajeong;Yoon, Duhak;Lee, Seung Hwan
    • Journal of Animal Science and Technology
    • /
    • v.63 no.6
    • /
    • pp.1232-1246
    • /
    • 2021
  • Recently, the cattle genome sequence has been completed, followed by developing a commercial single nucleotide polymorphism (SNP) chip panel in the animal genome industry. In order to increase statistical power for detecting quantitative trait locus (QTL), a number of animals should be genotyped. However, a high-density chip for many animals would be increasing the genotyping cost. Therefore, statistical inference of genotype imputation (low-density chip to high-density) will be useful in the animal industry. The purpose of this study is to investigate the effect of the reference population size and marker density on the imputation accuracy and to suggest the appropriate number of reference population sets for the imputation in Hanwoo cattle. A total of 3,821 Hanwoo cattle were divided into reference and validation populations. The reference sets consisted of 50k (38,916) marker data and different population sizes (500, 1,000, 1,500, 2,000, and 3,600). The validation sets consisted of four validation sets (Total 889) and the different marker density (5k [5,000], 10k [10,000], and 15k [15,000]). The accuracy of imputation was calculated by direct comparison of the true genotype and the imputed genotype. In conclusion, when the lowest marker density (5k) was used in the validation set, according to the reference population size, the imputation accuracy was 0.793 to 0.929. On the other hand, when the highest marker density (15k), according to the reference population size, the imputation accuracy was 0.904 to 0.967. Moreover, the reference population size should be more than 1,000 to obtain at least 88% imputation accuracy in Hanwoo cattle.

Use of measuring gauges for in vivo accuracy analysis of intraoral scanners: a pilot study

  • Iturrate, Mikel;Amezua, Xabier;Garikano, Xabier;Solaberrieta, Eneko
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.191-204
    • /
    • 2021
  • PURPOSE. The purpose of this study is to present a methodology to evaluate the accuracy of intraoral scanners (IOS) used in vivo. MATERIALS AND METHODS. A specific feature-based gauge was designed, manufactured, and measured in a coordinate measuring machine (CMM), obtaining reference distances and angles. Then, 10 scans were taken by an IOS with the gauge in the patient's mouth and from the obtained stereolithography (STL) files, a total of 40 distances and 150 angles were measured and compared with the gauge's reference values. In order to provide a comparison, there were defined distance and angle groups in accordance with the increasing scanning area: from a short span area to a complete-arch scanning extension. Data was analyzed using software for statistical analysis. RESULTS. Deviations in measured distances showed that accuracy worsened as the scanning area increased: trueness varied from 0.018 ± 0.021 mm in a distance equivalent to the space spanning a four-unit bridge to 0.106 ± 0.08 mm in a space equivalent to a complete arch. Precision ranged from 0.015 ± 0.03 mm to 0.077 ± 0.073 mm in the same two areas. When analyzing angles, deviations did not show such a worsening pattern. In addition, deviations in angle measurement values were low and there were no calculated significant differences among angle groups. CONCLUSION. Currently, there is no standardized procedure to assess the accuracy of IOS in vivo, and the results show that the proposed methodology can contribute to this purpose. The deviations measured in the study show a worsening accuracy when increasing the length of the scanning area.

Comparison of the estimated breeding value and accuracy by imputation reference Beadchip platform and scaling factor of the genomic relationship matrix in Hanwoo cattle

  • Soo Hyun, Lee;Chang Gwon, Dang;Mina, Park;Seung Soo, Lee;Young Chang, Lee;Jae Gu, Lee;Hyuk Kee, Chang;Ho Baek, Yoon;Chung-il, Cho;Sang Hong, Lee;Tae Jeong, Choi
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.3
    • /
    • pp.431-440
    • /
    • 2022
  • Hanwoo cattle are a unique and historical breed in Korea that have been genetically improved and maintained by the national evaluation and selection system. The aim of this study was to provide information that can help improve the accuracy of the estimated breeding values in Hanwoo cattle by showing the difference between the imputation reference chip platforms of genomic data and the scaling factor of the genetic relationship matrix (GRM). In this study, nine sets of data were compared that consisted of 3 reference platforms each with 3 different scaling factors (-0.5, 0 and 0.5). The evaluation was performed using MTG2.0 with nine different GRMs for the same number of genotyped animals, pedigree, and phenotype data. A five multi-trait model was used for the evaluation in this study which is the same model used in the national evaluation system. Our results show that the Hanwoo custom v1 platform is the best option for all traits, providing a mean accuracy improvement by 0.1 - 0.3%. In the case of the scaling factor, regardless of the imputation chip platform, a setting of -1 resulted in a better accuracy increased by 0.5 to 1.6% compared to the other scaling factors. In conclusion, this study revealed that Hanwoo custom v1 used as the imputation reference chip platform and a scaling factor of -0.5 can improve the accuracy of the estimated breeding value in the Hanwoo population. This information could help to improve the current evaluation system.