• Title/Summary/Keyword: Accuracy Standards

Search Result 493, Processing Time 0.027 seconds

A New Conceptual Network Synchronization System using Satellite time as an Intermediation parameter (위성시각을 매개로한 신 개념의 망동기시스템)

  • Kim, Young-Beom;Kwon, Taeg-Yong;Park, Byoung-Chul;Kim, Jong-Hyun
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.11-17
    • /
    • 2004
  • In this paper we propose a new conceptual system for a network clock in which all node clocks are simultaneously synchronized to the national standard by intermediation parameter of satellite time. Experiments have shown the possibility of its adoption by real networks. The new proposed method has various structural benefits, in particular all node clocks can be kept at the same hierarchical quality in contrast to the existing method. The measurement results show that the accuracy of the experimental slave clock system can be kept within a few parts In 1012 and the MTIE (Maximum Time Interval Error) sufficiently meets ITU-T G.811 for the primary reference clock. A prototype system with fully automatic operational functions has been realized at present and is expected to be directly used for communication network synchronization in the near future.

  • PDF

Measurement of Normal Spring Constant of Colloidal Probes for Atomic Force Microscope (원자 현미경용 콜로이드 탐침 수직 스프링 상수 측정)

  • Kim, Dae-Hyun;Kim, Min-Seok;Hahn, Junhee;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.212-217
    • /
    • 2012
  • A modified thermal noise method was proposed to measure the normal spring constants of the colloidal probes for an atomic force microscope. We used commercial tipless cantilevers (length 150, width 30, nominal k 7.4 N/m) and borosilicate spheres with a diameter of 20 to fabricate colloidal probes. The inverse optical lever sensitivity of both the tipless cantilever and colloidal probes were used to measure the normal spring constant of the colloidal probes. We confirmed the accuracy and usefulness of our method by comparing the measurement results with those obtained using the nanoforce calibrator (NFC), which reportedly has an uncertainty of 1.00%. The modified thermal method showed a good agreement (~10% difference) with the NFC, allowing us to conclude that the modified thermal method could be employed for the effective measurement of the normal spring constants of colloidal probes.

Repeatable calibration of Hounsfield units to mineral density and effect of scanning medium

  • Crookshank, Meghan;Ploeg, Heidi-Lynn;Ellis, Randy;MacIntyre, Norma J.
    • Advances in biomechanics and applications
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2014
  • Computed tomography (CT) is being utilized in orthopaedics and related research to estimate bone strength. These applications benefit from calibration of Hounsfield units to mineral density typical of long bone, up to $1750mg/cm^3$. This study describes a method for establishing repeatable calibration of Hounsfield units to density, and determines the effects of imaging medium on calibration accuracy. Four hydroxyapatite standards were imaged in air on 7 occasions over 19 weeks using a helical multi-slice CT scanner. Each standard was scanned 5 times in different media: porcine soft tissue, water, and air. Calibrated densities were highly repeatable (CV<3.5%). No difference in density was observed between water and soft tissue conditions (p>0.08). This work provides a model for determining repeatable scanner-specific density calibration, demonstrates that the linear relationship between Hounsfield units and density extends to values typical of cortical bone, and supports the practice of imaging calibration standards in an environment similar to that of the target bone.

Modeling Alignment Experiment Errors for Improved Computer-Aided Alignment

  • Kim, Yunjong;Yang, Ho-Soon;Song, Jae-Bong;Kim, Sug-Whan;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.525-532
    • /
    • 2013
  • Contrary to the academic interests of other existing studies elsewhere, this study deals with how the alignment algorithms such as sensitivity or Differential Wavefront Sampling (DWS) can be better used under effects from field, compensator positioning and environmental errors unavoidable from the shop-floor alignment work. First, the influences of aforementioned errors to the alignment state estimation was investigated with the algorithms. The environmental error was then found to be the dominant factor influencing the alignment state prediction accuracy. Having understood such relationship between the distorted system wavefront caused by the error sources and the alignment state prediction, we used it for simulated and experimental alignment runs for Infrared Optical System (IROS). The difference between trial alignment runs and experiment was quite close, independent of alignment methods; 6 nm rms for sensitivity method and 13 nm rms for DWS. This demonstrates the practical usefulness and importance of the prior error analysis using the alignment algorithms before the actual alignment runs begin. The error analysis methodology, its application to the actual alignment of IROS and their results are described together with their implications.

A Study on the DC Critical Current Test Method for 22.9kV/50MV A Superconducting Power Cable Considering the Uncertainty (불확도를 고려한 22.9kV, 50MVA급 초전도 전력케이블의 직류 임계전류 측정방법에 관한 연구)

  • Choi, S.J.;Lee, S.J.;Sim, K.D.;Cho, J.W.;Lee, S.K.;Yang, B.M.;Ko, T.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.46-49
    • /
    • 2009
  • A 3-phase 100m long, 22.9kV class HTS power transmission cable system was developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. those are participated in the 21st Century Frontier project R&D Program of Korea. It is important to test the DC critical current related with its power capacity before applying to the real power grid. In 1995, several international standards organizations including International Electrotechnical Commission (IEC), decided to unify the use of statistical terms related with 'accuracy' or 'precision' in their standards. It was decided to use the word 'uncertainty' for all quantitative (associated with a number) statistical expressions. In this paper, we measured DC critical current of 22.9kV/50MVA superconducting power cable with several voltage tap and analyzed the uncertainty with these results.

A Study on the proficiency test of pH measurements (pH 측정의 숙련도 시험에 대한 연구)

  • Lee, Hwashim;Kim, Myungsoo;Choi, Jongoh
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.230-237
    • /
    • 2001
  • In general, the pH measurement follows calibration of glass electrode system using pH standard solution. When pH is measured at constant temperature, uncertainty factors are mainly related to the accuracy of pH standard solution and the accuracy and precision of glass electrode. Participants in this proficiency test were the volunteers trying to know the distribution of the measured pH values for the same sample and the sources of error through 1998 and 1999. The samples for proficiency test are phosphate salt standard solutions specially prepared in KRISS, of which pH values were 6.860, 7.415(at $25^{\circ}C$), and the stability test was performed for the same periods of proficiency test. The results of the proficiency test were plotted according to Youden plot, which shows whether the error is random or systematic. The results of Youden plot showed that the source of error was from the systematic effect of laboratories in each year. This shows that the source of error is the standard solutions used in laboratories.

  • PDF

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

Deterministic Pitch Tool Polishing Using Tool Influence Function (드레이퍼 방식 연마기에서의 툴 영향 함수 기법)

  • Yi, Hyun-Su;Yang, Ho-Soon;Lee, Yun-Woo;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.6
    • /
    • pp.422-428
    • /
    • 2008
  • The pitch tool provides superior surface roughness compared to other types of polishing tool. However, because of difficulty in handling the pitch tool, pitch tool polishing has rarely been analysed, which led many craftsman to eliminate the pitch tool from their experiences. We found that it was possible to use a pitch tool in the well-determined material removal after the completion of computer simulation and experiment. We could simulate the TIF of the pitch tool with 79% accuracy. Also, after five successive simulations of polishing process on a 280 mm optical flat, the surface p-v error was found to be reduced from $1{\mu}m$ to 168 nm.

Basic Physiological Research on the Wing Flapping of the Sweet Potato Hawkmoth Using Multimedia

  • Nakajima, Isao;Yagi, Yukako
    • Journal of Multimedia Information System
    • /
    • v.7 no.2
    • /
    • pp.189-196
    • /
    • 2020
  • We have developed a device for recording biological data by inserting three electrodes and a needle with an angular velocity sensor into the moth for the purpose of measuring the electromyogram of the flapping and the corresponding lift force. With this measurement, it is possible to evaluate the moth-physiological function of moths, and the amount of pesticides that insects are exposed to (currently LD50-based standards), especially the amount of chronic low-concentration exposure, can be reduced the dose. We measured and recorded 2-channel electromyography (EMG) and angular velocity corresponding to pitch angle (pitch-like angle) associated with wing flapping for 100 sweet potato hawkmoths (50 females and 50 males) with the animals suspended and constrained in air. Overall, the angular velocity and amplitude of EMG signals demonstrated high correlation, with a correlation coefficient of R = 0.792. In contrast, the results of analysis performed on the peak-to-peak (PP) EMG intervals, which correspond to the RR intervals of ECG signals, indicated a correlation between ΔF fluctuation and angular velocity of R = 0.379. Thus, the accuracy of the regression curve was relatively poor. Using a DC amplification circuit without capacitive coupling as the EMG amplification circuit, we confirmed that the baseline changes at the gear change point of wing flapping. The following formula gives the lift provided by the wing: angular velocity × thoracic weight - air resistance - (eddy resistance due to turbulence). In future studies, we plan to attach a micro radio transmitter to the moths to gather data on potential energy, kinetic energy, and displacement during free flight for analysis. Such physiological functional evaluations of moths may alleviate damage to insect health due to repeated exposure to multiple agrochemicals and may lead to significant changes in the toxicity standards, which are currently based on LD50 values.

Development of Calibration Target for Infrared Thermal Imaging Camera (적외선 열화상 카메라용 캘리브레이션 타겟 개발)

  • Kim, Su Un;Choi, Man Yong;Park, Jeong Hak;Shin, Kwang Yong;Lee, Eui Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.248-253
    • /
    • 2014
  • Camera calibration is an indispensable process for improving measurement accuracy in industry fields such as machine vision. However, existing calibration cannot be applied to the calibration of mid-wave and long-wave infrared cameras. Recently, with the growing use of infrared thermal cameras that can measure defects from thermal properties, development of an applicable calibration target has become necessary. Thus, based on heat conduction analysis using finite element analysis, we developed a calibration target that can be used with both existing visible cameras and infrared thermal cameras, by implementing optimal design conditions, with consideration of factors such as thermal conductivity and emissivity, colors and materials. We performed comparative experiments on calibration target images from infrared thermal cameras and visible cameras. The results demonstrated the effectiveness of the proposed calibration target.