• Title/Summary/Keyword: Accuracy Standard

Search Result 2,426, Processing Time 0.035 seconds

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

Precision evaluation of the treatment that used coordinates confirmation of couch in case of two forgets adjoined. (Couch의 좌표 확인을 이용한 치료 위치 이동의 정확성 평가)

  • Seo Jeong-min;Jeong Cheon-young;Park Young-hwan;Song Ki-won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2003
  • I. Purpose Confirming an error to be able to break out in a method to move couch manually while operator sees the skin marks on patient in case of curing head who got 2 targets adjoined, so we analyze coordinates price of couch, evaluate reproducibility and precision of change movements between targets. II. Materials and Methods In radiotherapy, for confirming errors in manual movements by operators by exchanging between two targets to treat patient head, we read coordinates price(vertical, longitudinal, lateral three directions of couch) shown on a monitor of LINAC( CL 2100, Varian, USA) in order to evaluate accuracy about the length that moved in time for moving couch manually. After reading movement length of coordinates recorded in three directions of all treatment, we compared distance between targets recorded in RTP(Pinnacle, ADAC, USA) with reading coordinates price of couch, setting actually done the same patient for ten times, coordinates were recorded, treated for evaluating averages and degrees of errors and standard deviations. III. Results In method to confirm skin marks of patient by operators' view and to move couch manually, average standard deviations of movements between two targets are vertical 1.4mm, longitudinal 0.9mm, lateral 2.2mm in each direction. As for the error in straight dimension, it is about 3.6mm averages and 5.1mm maximum. The average of errors in each directions was vertical 1mm, longitudinal 0.7mm, lateral 2.7mm. The greatest error broke out in lateral direction with $25\%$ of all cases ; to exceed an error average. IV. Conclusions If operators moved manually couch for changing target points, errors about 3.6mm average degrees occur. It is important that operators confirm the errors prices of actual couch coordinates for asking a correct movement between the targets adjoined each other ; in case of treatment demanding high precision like 3D conformal therapy or IMRT. Therefore, if we apply couch coordinates confirmation to reproducibility and to precision evaluation of treatment, it's expected that we can execute high-quality radiotherapy.

  • PDF

Measurement of Image Quality According to the Time of Computed Radiography System (시간에 따르는 CR장비의 영상의 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Hwang, Sun-Kwang;Lee, Ik-Pyo;Kim, Ki-Won;Jung, Jae-Yong;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.365-374
    • /
    • 2015
  • The regular quality assurance (RQA) of X-ray images is essential for maintaining a high accuracy of diagnosis. This study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) of a computed radiography (CR) system for various periods of use from 2006 to 2015. We measured the pre-sampling MTF using the edge method and RQA 5 based on commission standard international electro-technical commission (IEC). The spatial frequencies corresponding to the 50% MTF for the CR systems in 2006, 2009, 2012 and 2015 were 1.54, 1.14, 1.12, and $1.38mm^{-1}$, respectively and the10% MTF for 2006, 2009, 2012, and 2015 were 2.68, 2.44, 2.44, and $2.46mm^{-1}$, respectively. In the NPS results, the CR systems showed the best noise distribution in 2006, and with the quality of distributions in the order of 2015, 2009, and 2012. At peak DQE and DQE at $1mm^{-1}$, the CR systems showed the best efficiency in 2006, and showed better efficiency in order of 2015, 2009, and 2012. Because the eraser lamp in the CR systems was replaced, the image quality in 2015 was superior to those in 2009 and 2012. This study can be incorporated into used in clinical QA requiring performance and evaluation of the performance of the CR systems.

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.

Low Dilution Glass Bead Digestion Technique for the Trace Element Analysis of Rock Samples (저희석 유리구 용해법에 의한 암석시료 미량원소 분석법)

  • Park, Chan-Soo;Shin, Hyung-Seon;Oh, Hae-Young;Moon, Jong-Hwa;Cheong, Chang-Sik
    • The Journal of the Petrological Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.161-172
    • /
    • 2011
  • Open beaker digestion method is routinely used as the sample preparation technique for trace element determination of rock samples by inductively coupled plasma mass spectrometry, With this method, however, dissolution of Zr and Hf is not always guaranteed especially when the samples contain refractory minerals. In this study, glass bead digestion technique was compared with conventional open beaker digestion technique for the sample preparation of three USGS rock standards such as AGV-2, BHVO-2, and G-3. Thirty trace elements including rare earth elements were analysed by ICP-MS and ICP-AES. There were no clear differences in analytical results for the AGV-2 and BHVO-2 standards between the two techniques, but Zr, Hf, Y, and middle- to heavy- rare earth element concentrations of the G-3 standard prepared by open beaker digestion technique were significantly lower than the recommended values. This can be attributed to the presence of refractory mineral zircon. On the contrary, all the analytical results of the G-3 standard prepared by glass bead digestion technique were in good agreement with the recommended values, indicating complete dissolution of zircon. The analytical results show that the volatile elements such as Pb and Zn were not lost during the preparation of glass bead. Low dilution glass bead digestion technique described here will be very helpful to enhance precision and accuracy of trace element analysis for geological samples containing refractory minerals.

The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters (Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계)

  • Kim, Min-Chul;Kwon, Kee-Buem;Yim, Dong-Hyun;Song, Chang-Seuk;Jung, Yong-Seuk;Jang, Tae-Won;Yeu, Ho-Dae;Jung, Maan-Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.1000-1011
    • /
    • 1998
  • Background: For the diagnosis or evaluation of airway obstruction in bronchial asthma and chronic obstructive lung disorders, various parameters derived from the forced expiratory volume curve and maximal expiratory flow volume curve have been used. Recently the peak expiratory flow(PEF) measured by the peak flow meter is widely used because of its simplicity and convenience. But there were still no data of the predicted normal values measured by the peak flow meter in Korea. This study was to obtain the predicted normal value of PEF and to know the accuracy of this value to predict $FEV_1$. Method: The measurements of PEF by the MiniWright peak flow meter and several parameters derived from the forced expiratory volume and maximal expiratory flow volume curves by the Microspiro HI 501(Chest Co.) were done in 129 men and 125 women without previous history of the respiratory diseases. The predicted normal values of parameters according to the age and the height were obtained, and the regression equation of $FEV_1$ by PEF was calculated. Results: The predicted normal values of PEF(L/min) were -2.45$\times$Age(year) +1.36 $\times$ Height(cm)+427 in men, and -0.96 $\times$ Age (year) + 2.01 $\times$ Height (cm) + 129 in women. FEFmax derived from the maximal expiratory flow volume curve was less than by 125 L/min in men and 118 L/min in women respectively compared to PEF. $FEV_1$(ml) predicted by PEF was 5.98 $\times$ PEF(L/min) + 303 in men, and 4.61 $\times$ PEF(L/min) + 291 in women respectively. Conclusion : The predicted normal value of PEF measured by the peak flow meter was calculated and it could be used as a standard value of PEF while taking care of patients with airway obstruction. $FEV_1$, the gold standard of ventilatory function, could be predicted by PEF to a certain extent.

  • PDF

Investigation of Water-soluble Vitamin (B1, B2, and B3) Contents in Various Roasted, Steamed, Stir-fried, and Braised Foods Produced in Korea (국내 식품 중 구이, 찜, 볶음, 조림에 존재하는 수용성 비타민 B1, B2 그리고 B3 함량 조사)

  • Cho, Jin-Ju;Hong, Seong Jun;Boo, Chang Guk;Jeong, Yuri;Jeong, Chang Hyun;Shin, Eui-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.5
    • /
    • pp.454-462
    • /
    • 2019
  • A conventional Korean meal typically includes various roasted, steamed, stir-fried, and braised foods. For this study, we investigated the contents of water soluble vitamins, $B_1$ (thiamin), $B_2$ (riboflavin) and $B_3$ (niacin) in various roasted, steamed, stir-fried, and braised foods. Method validation for analytical data in this study showed a high linearity ($r^2$>0.999), and the limit of detection and quantification were 0.001-0.067 and $0.002-0.203{\mu}g/mL$, respectively. For accuracy and precision, analytical values using standard reference materials were in the certified ranges. Roasted foods contained 0.039-1.057 mg/100 g of thiamin, 0.058-0.686 mg/100 g of riboflavin and 0.021-21.772 mg/100 g of niacin. Steamed foods contained 0.049-1.066 mg/100 g of thiamin, 0.025-0.548 mg/100 g of riboflavin and 0.134-21.509 mg/100 g of niacin. Stir-fried foods contained 0.114-0.388 mg/100 g of thiamin, 0.014-1.258 mg/100 g of riboflavin and 0.015-2.319 mg/100 g of niacin. Braised foods contained 0.112-1.656 mg/100 g of thiamin, 0.024-0.298 mg/100 g of riboflavin and 0.322-2.157 mg/100 g of niacin. The data on water-soluble vitamins in this study can be used for a nutritional database of conventional Korean meals.

Contents of vitamin B9 (folate) and B12 (cobalamins) in commonly consumed seafood menus in Korea (한국인 상용 수산물 식단의 비타민 B9과 B12 함량)

  • Park, Eun-Young;Jeong, Bomi;Chun, Jiyeon
    • Journal of Nutrition and Health
    • /
    • v.54 no.2
    • /
    • pp.211-223
    • /
    • 2021
  • Purpose: A total of 39 seafood menus were prepared according to the Korean standard recipe, and analyzed for vitamin B9 (folate) and B12 (cobalamins) contents, using validated applied analytical methods. The menus included Guk/Tang/Jjigae (boiled or stewed dishes, n = 10), Bokkeum (stir-fried dishes, n = 10), Jjim/Jorim (braised or steamed dishes, n = 7), Gui (baked or grilled dishes, n = 7), Twigim (deep-fried dishes, n = 2) and Muchim (dried or blanched-seasoned dishes, n = 3). Methods: The contents of vitamin B9 and B12 in all food samples were determined by the trienzyme extraction-Lactobacillus casei and immunoaffinity-high-performance liquid chromatography/photodiode array detection methods. Analytical quality control was performed in order to assure reliability of the analysis. Results: Accuracy (97.4-100.6% recoveries) and precision (< 6% relative standard deviations for repeatability and reproducibility) of vitamin B9 and B12 analyses were determined to be excellent. The vitamin B9 and B12 contents of the 39 seafood menus evaluated, varied in the range of 1.83-523.08 ㎍/100 g and 0.11-38.30 ㎍/100 g, respectively, depending on the ingredients and cooking methods. The vitamin B9 content was highest in Jomi-gim (523.08 ㎍/100 g), followed by Geonsaeu-bokkeum (128.34 ㎍/100 g) and Janmyeolchi-bokkeum (121.53 ㎍/100 g). Vitamin B12 was detected in all seafood menus, with highest level obtained in Kkomack-jjim (41.58 ㎍/100 g). The seaweed dish was found to have high levels of both vitamin B9 and B12. All assays were performed under strict quality control. Conclusion: Guk and Tang menus, which contain a large amount of water, were relatively lower in the vitamin B9 and B12 contents than the other menus. Bokkeum menus containing various vegetables were high in the vitamin B9 content, but the vitamin B12 content was dependent on the type of seafood used in the menu.

Evaluating of the Effectiveness of RTK Surveying Performance Based on Low-cost Multi-Channel GNSS Positioning Modules (다채널 저가 GNSS 측위 모듈기반 RTK 측량의 효용성 평가)

  • Kim, Chi-Hun;Oh, Seong-Jong;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.53-65
    • /
    • 2022
  • According to the advancement of the GNSS satellite positioning system, the module of hardware and operation software reflecting accuracy and economical efficiency is implemented in the user sector including the multi-channel GNSS receiver, the multi-frequency external antenna and the mobile app (App) base public positioning analysis software etc., and the multichannel GNSS RTK positioning of the active configuration method (DIY, Do it yourself) is possible according to the purpose of user. Especially, as the infrastructure of multi-GNSS satellite is expanded and the potential of expansion of utilization according to various modules is highlighted, interest in the utilization of multi-channel low-cost GNSS receiver module is gradually increasing. The purpose of this study is to review the multi-channel low-cost GNSS receivers that are appearing in the mass market in various forms and to analyze the utilization plan of the "address information facility investigation project" of the Ministry of Public Administration and Security by constructing the multi-channel low-cost GNSS positioning module based RTK survey system (hereinafter referred to as "multi-channel GNSS RTK module positioning system"). For this purpose, we constructed a low-cost "multi-channel GNSS RTK module positioning system" by combining related modules such as U-blox's F9P chipset, antenna, Ntrip transmission of GNSS observation data and RTK positioning analysis app through smartphone. Kinematic positioning was performed for circular trajectories, and static positioning was performed for address information facilities. The results of comparative analysis with the Static positioning performance of the geodetic receivers were obtained with 5 fixed points in the experimental site, and the good static surveying performance was obtained with the standard deviation of average ±1.2cm. In addition, the results of the test point for the outline of the circular structure in the orthogonal image composed of the drone image analysis and the Kinematic positioning trajectory of the low cost RTK GNSS receiver showed that the trajectory was very close to the standard deviation of average ±2.5cm. Especially, as a result of applying it to address information facilities, it was possible to verify the utility of spatial information construction at low cost compared to expensive commercial geodetic receivers, so it is expected that various utilization of "multi-channel GNSS RTK module positioning system"

Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA (근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가)

  • Seung-Woo Yang;Sung-Kwang Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy is a cancer treatment that intensively irradiates radiation to tumors by inserting isotopes with high dose rates into the body. For such a treatment, it is necessary to deliver an accurate dose to the tumor tissue through an accurate treatment plan while delivering only a minimum dose to the normal tissue. Therefore, it is very important to check the location accuracy of the source through accurate Quality Assurance (QA) in clinical practice. However, since the source position is determined using a ruler, automatic radiographer, video monitor, etc. in clinical practice, it yields inaccurate results. In this study, a semiconductor dosimeter using CsPbI2Br and CsPbIBr2 was fabricated. And, in order to analyze whether it is more suitable for the relative QA dosimeter for brachytherapy device among the two materials, the radiation detection ability of each was compared and evaluated. In order to evaluate the radiation detection ability in brachytherapy, the reproducibility and linearity of the two materials were evaluated in 192IR. In the reproducibility evaluation, CsPbI2Br presented a Relative Standard Deviatio(RSD) of 0.98% and CsPbIBr2 presented an RSD of 3.45%. In the linearity evaluation, the coefficient of determination (R2) of CsPbI2Br was presented as 0.9998, and the R2 of CsPbIBr2 was presented as 0.9994. As a result of the evaluation, it was found that CsPbI2Br was more stable in radiation detection while satisfying the evaluation criteria in the dosimeter manufactured in this experiment. Therefore, CsPbI2Br material is suitable for application as a relative dosimeter for radiation detection in brachytherapy devices.