• Title/Summary/Keyword: Accuracy Standard

Search Result 2,426, Processing Time 0.04 seconds

Improvement of accuracy in quantitative TXRF analysis of soil sample by applying external standard method (외부표준법을 적용한 토양시료의TXRF 정량분석 정확도 개선)

  • Park, Jinkyu;Park, Ranhee;Han, Sun Ho;Lim, Sang Ho;Lee, Chi Gyu;Song, Kyuseok
    • Analytical Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.261-268
    • /
    • 2016
  • TXRF is a powerful technique for the soil sample analysis due to its ability to conduct quantitative analysis of powder sample without complicated pre-treatment processes. The conventional internal standard method used for this technique suffers from relatively low accuracy because of varying matrix effects of soil. In order to improve the accuracy, external standard method was applied to analyze two types of soil samples; acid-dissolutionized soil solution and detergent-suspended soil powder. Individual ICP-AES/MS grade standards were mixed, diluted and measured to create standard curves, but applying these curves for analyzing the soil solution sample did not make any improvement in comparison with the internal standard method. On the other hand, standard curves were created with using standard soil powders for the analysis of soil powder samples, and we found that this method increased the accuracy significantly relative to the internal standard method. Especially, Al, Fe, K, Ca, Ti, Ba, Mn, Sr, Rb, Cu was measured with relatively high accuracy (relative error = ${\pm}20%$).

Analysis of Distance Measurement Accuracy in Aerial and Satellite Image Photogrammetry (항공사진측량과 위성영상측량에서 거리측정 정확도 연구)

  • Kim, Hyung-Moo;Tcha, Dek-Kie;Nam, Guon-Mo;Yang, Chul-Soo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.253-255
    • /
    • 2010
  • Needs to study on distance measurement accuracy in aerial and satellite photogrammetry are rapidly increased. However, conventional studies show some confused definitions between measurement accuracy and measurement precision as well as standard deviation(STDEV) and root mean square error(RMSE or RMSD). So, Finite definitions of measurement accuracy and measurement precision as well as STDEV and RMSD are addressed in this paper. Experiment result show using correct definitions improve the distance measurement accuracy in aerial and satellite photogrammetry rapidly, but not the distance measurement accuracy in aerial and satellite photogrammetry.

  • PDF

Computerized bone age estimation system based on China-05 standard

  • Yin, Chuangao;Zhang, Miao;Wang, Chang;Lin, Huihui;Li, Gengwu;Zhu, Lichun;Fei, Weimin;Wang, Xiaoyu
    • Advances in nano research
    • /
    • v.12 no.2
    • /
    • pp.197-212
    • /
    • 2022
  • The purpose of this study is to develop an automatic software system for bone age evaluation and to evaluate its accuracy in testing and feasibility in clinical practice. 20394 left-hand radiographs of healthy children (2-18 years old) were collected from China Skeletal Development Survey data of 1998 and China Skeletal Development Survey data of 2005. Three experienced radiologists and China-05 standard maker jointly evaluate the stages of bone development and the reference bone age was determined by consensus. 1020 from 20394 radiographs were picked randomly as test set and the remaining 19374 radiographs as training set and validation set. Accuracy of the automatic software system for bone age assessment is evaluated in test set and two clinical test sets. Compared with the reference standard, the automatic software system based on RUS-CHN for bone age assessment has a 0.04 years old mean difference, ±0.40 years old in 95% confidence interval by single reading, a 85.6% percentage agreement of ratings, a 93.7% bone age accuracy rate, 0.17 years old of MAD, 0.29 years old of RMS; Compared with the reference standard, the automatic software system based on TW3-C RUS has a 0.04 years old mean difference, a ±0.38 years old in 95% confidence interval by single reading, a 90.9% percentage agreement of ratings, a 93.2% bone age accuracy rate, a 0.16 years of MAD, and a 0.28 years of RMS. Automatic software system, AI-China-05 showed reliably accuracy in bone age estimation and steady determination in different clinical test sets.

A Study on the Accuracy Verification Criteria in Underground Facilities Surveying Using GPR (지하시설물 측량에 있어서 GPR 탐사방법의 정확도 검증 기준에 관한 연구)

  • OH, Yi-Kyun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.2
    • /
    • pp.35-49
    • /
    • 2021
  • In order to manage the underground spatial information in systematic and effective way, production of an integration underground spatial information map is essential process. The government has been making efforts to expand manage the production of 3D underground spatial integrated map. In recent the GPR is actively used for exploring underground facilities in non-exploring area and sinkhole. For achieving the research objectives presenting the accuracy of verification standard in underground spatial information surveying using GPR, the related legislation standard, the experiment resutls and international criteria have been analyzed. From this research it is found that the accuracy standard has been made by the related academic society(USA) and association(UK) in foreign counties. It is recommended that indicate the verification standard with number and percent together considering the characteristics of GPR.

The relationship between prediction accuracy and pre-information in collaborative filtering system

  • Kim, Sun-Ok
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.803-811
    • /
    • 2010
  • This study analyzes the characteristics of preference ratings by dividing estimated values into four groups according to rank correlation coefficient after obtaining preference estimated value to user's ratings by using collaborative filtering algorithm. It is known that the value of standard error of skewness and standard error of kurtosis lower in the group of higher rank correlation coefficient This explains that the preference of higher rank correlation coefficient has lower extreme values and the differences of preference rating values. In addition, top n recommendation lists are made after obtaining rank fitting by using the result ranks of prediction value and the ranks of real rated values, and this top n is applied to the four groups. The value of top n recommendation is calculated higher in the group of higher rank correlation coefficient, and the recommendation accuracy in the group of higher rank correlation coefficient is higher than that in the group of lower rank correlation coefficient Thus, when using standard error of skewness and standard error of kurtosis in recommender system, rank correlation coefficient can be higher, and so the accuracy of recommendation prediction can be increased.

A Strategy for Production of Digital Elevation Models in Korea

  • Lee, Chung-Kyung;CHO, Kyu-Jon;RYU, Joong-Hi
    • Korean Journal of Geomatics
    • /
    • v.3 no.2
    • /
    • pp.107-114
    • /
    • 2004
  • The National Geographic Information Institute (NGII) in korea, through the National Geographic Information System (NGIS) Program, has prepared to generate and disseminate digital elevation data for Korea. This is a pilot research to propose a policy for production, maintenance, and supply of Korea Digital Elevation Data(KDED). Customer demands for accuracy and resolution of DEM was surveyed through a questionnaire. In order to investigate the quality, the technical efficiency and the production cost, a tentative DEM in a small test site was generated based on digital topographic maps (original paper map scale 1:5,000), analytical plotter, and LIDAR. The Accuracy standard for KDED was derived based on source data generation methods. As a result of this research, a uniformly spaced grid model was recommended for KDED. Its preferable grid space is 5m in urban areas and its vicinity, and 10m in field and mountainous area. LIDAR has been valuated as a proper KDED generation method fulfilling customers' demands for the accuracy.

  • PDF

Study of improving precision and accuracy by using an internal standard in post column isotope dilution method for HPLC-ICP/MS (후 컬럼 동위원소 희석법을 적용한 HPLC-ICP/MS에서의 정량분석에서 내부 표준물을 이용한 정확도와 정밀도의 개선연구)

  • Joo, Mingyu;Park, Myungsun;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.140-146
    • /
    • 2014
  • An internal standard was used in PCID (post column isotope dilution) to improve the accuracy and precision in quantification of various chemical species. The error occurring in the column was the largest in HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry) when PCID and other traditional quantification methods were compared with each other. Internal standard was effective in correcting the loss of sample in the column to improve accuracy and precision. When applied to SeMet, using MeSecys or $Se^{4+}$ as an internal standard, relative errors were reduced from 31% and 13% to less than 1%, while standard deviations were reduced from 5.1% and 6.9% to 1.5% and 0.2%, respectively. Positive aspects of using an internal standard in PCID were compared with other quantitative techniques and discussed in detail.

Scanner Certification Tool for the Standardization of Digitized Documents: Focusing on Target Factors and Measurement Programs

  • Park, Hyung-Ju;Har, Dong-Hwan
    • International Journal of Contents
    • /
    • v.6 no.3
    • /
    • pp.25-29
    • /
    • 2010
  • Scanners play an important role in digitally reproducing the color and imaging of original documents used in public offices; however, the current system lacks a standard for digitized documents created by scanners, complicating efforts to create a digitized system. In particular, macrography cannot guarantee the accuracy and reliability of digitalized color documents, pictures, and photographs created by scanners. To this end, we develop a standardized evaluation tool and test target to certify digitalized documents created by a scanner in the domestic environment. In this study, we enhance the accuracy and reliability of scanned data to create an advanced standard evaluation tool for scanners. Moreover, to produce a scanner certification standard, we overcome existing problems related to the growing market. We anticipate that this new standard will see a high degree of application in the current environment.

A Study on the Structure of Time Unit and SIMO of MODAPTS and Development of High Task MODAPTS(HITMAT) (MODAPTS의 시간단위 및 동시동작의 구조와 High Task MODAPTS(HITMAP)의 개발에 관한 연구)

  • Park, Seong-Hak
    • Journal of Korean Society for Quality Management
    • /
    • v.20 no.2
    • /
    • pp.137-142
    • /
    • 1992
  • MODAPTS has been widely used for establishing the standard time of manual works because of easy application of the system. However this system was developed based on MTM, winch was one of the low task standard. Also in this system, it usually becomes a cause of error in accuracy that all the simultaneous motions(SIMO) should be analyzed in the sequent motions of two hands. In order to improve the weak points of MODAPTS, the structure of time unit and SIMO of MODAPTS was researched, and HITMAP was developed on the basis of Work Factor System which was one of the high task standard. HITMAP is composed of 26 standard elements and it's time unit is MD(1MD=0.1 second) and MGSRMPS is the motion pattern of HITMAP. In this study HITMAP shows more than 95% of accuracy to WF. Therefor, it is expected that HITMAP can be used for the improvement of productivity and incentive systems.

  • PDF

Evaluation of Seismic Performance for Bridge Structure Using Capacity Spectrum Method (역량스펙트럼법을 이용한 교량의 내진성능평가)

  • 이창수;김승익;김현겸
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.75-80
    • /
    • 2000
  • Evaluation method of seismic performance has mainly used elastic spectrum analysis. This method has simplicity of analysis but deficiency of accuracy. And evaluation method of seismic performance using inelastic dynamic analysis reflects accurately inelasticity of material but hardly reflects site effects. This study suggested evaluation scheme of seismic performance for bridge structure using capacity spectrum method applied inelastic static analysis and standard design response spectrum of Korea Standard Specification for Highway Bridge. Two results, capacity spectrum method and inelastic dynamic analysis method, are very similar. As a result, this study appropriately supply both simplicity of analysis and accuracy of result.

  • PDF