• Title/Summary/Keyword: Accuracy Rate

Search Result 3,423, Processing Time 0.03 seconds

Development and Application of Convergence Education about Support Vector Machine for Elementary Learners (초등 학습자를 위한 서포트 벡터 머신 융합 교육 프로그램의 개발과 적용)

  • Yuri Hwang;Namje Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.95-103
    • /
    • 2023
  • This paper proposes an artificial intelligence convergence education program for teaching the main concept and principle of Support Vector Machines(SVM) at elementary schools. The developed program, based on Jeju's natural environment theme, explains the decision boundary and margin of SVM by vertical and parallel from 4th grade mathematics curriculum. As a result of applying the developed program to 3rd and 5th graders, most students intuitively inferred the location of the decision boundary. The overall performance accuracy and rate of reasonable inference of 5th graders were higher. However, in the self-evaluation of understanding, the average value was higher in the 3rd grade, contrary to the actual understanding. This was due to the fact that junior learners had a greater tendency to feel satisfaction and achievement. On the other hand, senior learners presented more meaningful post-class questions based on their motivation for further exploration. We would like to find effective ways for artificial intelligence convergence education for elementary school students.

Determination of itraconazole in human plasma by high performance liquid chromatography (HPLC/UV를 이용한 혈장 중 이트라코나졸의 분석)

  • Jang, Hae Jong;Lee, Ye Rie;Lee, Kyung Ryul;Han, Sang-Beom;Kang, Seung Woo;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.239-243
    • /
    • 2006
  • This method is used for the determination of itraconazole in human plasma by liquid-liquid extraction and high performance liquid chromatography. Felodipine was used as an internal standard. After extraction of the plasma with diethyl ether, the centrifuged upper layer was then transferred. The supernantant was evaporated and then reconsituted with mobile phase. The mobile phase was composed of 10 mM ammonium acetate adjusted to pH 7 by phosphoric acid with a flow rate of 0.2 mL/min. A C18 reversed-phase column with a pre-column was used as the analytial column. Linear detection responses were obtained for itraconzole concentration range for 2~1,000 ng/mL. The correlation coefficient of linear regression($R^2$) was 0.9991, limit of quantification (LOQ) was 2 ng/mL, reproducibility was less than 10.8 %, and accuracy was 97.2~108.2%. This method has been successfully applied to the pharmacokinetic study of itraconazole in human plasma.

Rapid and simultaneous determination of metabolites of organic solvents in human urine by high-performance liquid chromatography using a monolithic column (Monolithic 칼럼을 이용한 뇨 중 유기용매 대사체의 신속한 HPLC 동시 분석)

  • Han, Sang Beom;Lee, Sang-Ju;Lee, Cheol-Woo;Yoon, Seo Hyun;Joung, Sun Kyung;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.433-440
    • /
    • 2006
  • A HPLC/UV method was developed and validated for the rapid and simultaneous determination of urinary metabolites of organic solvents, mandelic acid, hippuric acid, phenylglyoxylic acid, ortho-, meta- and para-methylhippuric acid, using a monolithic column. The mobile phase was composed of tetrabutylammonium bromide as ion-pairing reagent with a flow rate of 2.4 mL/min. The total run time was less than 2.5 min for all six analytes. Good linearities were obtained for all the metabolites with correlation coefficients above 0.9993. Intra-day precision, accuracy and inter-day precision was 0.01~7.32%, 83.9~116.3% and 0.01~7.16%, respectively. The method was validated and confirmed by quantification of the quality assurance samples of Industrial Safety and Health Research Institute, Korea Occupational Safety and Health Agency.

Determination of residual novobiocin in livestock products and fisheries products by HPLC (HPLC를 이용한 축·수산 식품 중 잔류 노보비오신의 분석)

  • Lee, Byung Kyu;Lee, Cheol-Woo;Lee, Sang-Ju;Jung, Eun Ha;Lim, Hyun Kyun;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.347-354
    • /
    • 2007
  • A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in bovine, porcine, chicken, flatfish and japanese eel muscle has been developed and validated. The separation condition for HPLC/UV was optimized with phenyl hexyl ($4.6{\times}150mm$, $5{\mu}m$) column with 10 mM monobasic sodium phosphate buffer (pH 2.5)/acetonitrile (50/50, v/v) as the mobile phase at a flow rate of 1.0 mL/min and detection wavelength was set at 254 nm. Residues were extracted from tissue by blending with methanol and lipid materials were removed with n-hexane. Then, the methanol extract was evaporated to dryness under a nitrogen stream, reconstituted in the mobile phase. Aliquot of the organic extract was decanted and filtered through $0.45{\mu}m$ syringe filter. The $20{\mu}L$ of the resulting solution was injected into the HPLC system. The calibration ranges were $0.5{\sim}5{\mu}g/g$ and calibration curves were linear with coefficients of correlation better than 0.95. The limits of quantification were $0.5{\mu}g/g$ for all muscles. The recoveries of bovine, porcine, chicken, flatfish and japaneseel muscles were 99.8%, 102.4%, 91.0%, 104.0% and 93.0%, respectively. The procedures were validated according to the CODEX guideline, determining specificity, linearity, accuracy, precision, quantitation limit and recovery.

Quantity-based Early Cost Estimation Model for Road Construction Projects (대표물량 기반의 도로공사 설계단계의 개략공사비 예측모델)

  • Kim, Du Yon;Kim, Byungil;Yeo, Donghoon;Han, Seung Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3D
    • /
    • pp.373-379
    • /
    • 2009
  • Cost estimation in the early phase enables government to plan public budgeting more efficiently by providing information about construction cost. However, cost estimation in the early phase is difficult to predict because only a little information can be utilized. The cost estimation method now being used by the government is calculated by length of the road multiplied by unit cost per length and shows high error rate because it cannot reflect the unique characteristics of each project. As the project is being proceeded, level of available information also changed. So, reflecting available information of a project is important. This paper divided early phase into two parts : planning phase and early design phase, and developed cost estimation model considering level of available information of each phase. Total 143 cases are utilized to find influencing variables and develop cost estimation model and model validation is done by adopting required accuracy level. This cost estimation model reflecting level of available information can be applied to public budgeting, feasibility test, and comparison between routes.

A Study on the Classification Model of Overseas Infringing Websites based on Web Hierarchy Similarity Analysis using GNN (GNN을 이용한 웹사이트 Hierarchy 유사도 분석 기반 해외 침해 사이트 분류 모델 연구)

  • Ju-hyeon Seo;Sun-mo Yoo;Jong-hwa Park;Jin-joo Park;Tae-jin Lee
    • Convergence Security Journal
    • /
    • v.23 no.2
    • /
    • pp.47-54
    • /
    • 2023
  • The global popularity of K-content(Korean Wave) has led to a continuous increase in copyright infringement cases involving domestic works, not only within the country but also overseas. In response to this trend, there is active research on technologies for detecting illegal distribution sites of domestic copyrighted materials, with recent studies utilizing the characteristics of domestic illegal distribution sites that often include a significant number of advertising banners. However, the application of detection techniques similar to those used domestically is limited for overseas illegal distribution sites. These sites may not include advertising banners or may have significantly fewer ads compared to domestic sites, making the application of detection technologies used domestically challenging. In this study, we propose a detection technique based on the similarity comparison of links and text trees, leveraging the characteristic of including illegal sharing posts and images of copyrighted materials in a similar hierarchical structure. Additionally, to accurately compare the similarity of large-scale trees composed of a massive number of links, we utilize Graph Neural Network (GNN). The experiments conducted in this study demonstrated a high accuracy rate of over 95% in classifying regular sites and sites involved in the illegal distribution of copyrighted materials. Applying this algorithm to automate the detection of illegal distribution sites is expected to enable swift responses to copyright infringements.

Evaluation of Applicability of Customized Bolus According to 3D Printer Material Characteristics (3D 프린터 소재 특성에 따른 맞춤형 볼루스의 적용성 평가)

  • Kyung-Tae Kwon;Hui-Min Jang;Myeong-Seong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1091-1097
    • /
    • 2023
  • Bolus is used in radiation therapy to prescribe an even dose to the tumor when the skin surface is inclined or has irregularities. At this time, the dose to the skin surface increases. Due to the patient's unique body structure and irregular skin, voids may occur between the bolus and the skin, which may reduce the accuracy of treatment. Therefore, in this study, the existing bolus and the self-produced bolus through 3D printing were applied to the nasal area, and the difference between the surface dose after treatment plan and the dose directly measured with an Optically Stimulated luminescence(OSL) dosimeter was compared to the existing bolus. The bolus rate was 97%, PLA 100.33%, ePETELA 75A 100.53%, and ePETELA 85A 100.36%. It was confirmed that there was little error in the measurement values and treatment plan values for each material. In addition, compared to when applying a conventional bolus, a difference of -3% to +0.5% for a 3D printed bolus can be confirmed, so a customized bolus produced through 3D printing can complement the shortcomings of the existing bolus. It is believed that there will be.

A Comparative Study on Prediction Performance of the Bankruptcy Prediction Models for General Contractors in Korea Construction Industry

  • Seung-Kyu Yoo;Jae-Kyu Choi;Ju-Hyung Kim;Jae-Jun Kim
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.432-438
    • /
    • 2011
  • The purpose of the present thesis is to develop bankruptcy prediction models capable of being applied to the Korean construction industry and to deduce an optimal model through comparative evaluation of final developed models. A study population was selected as general contractors in the Korean construction industry. In order to ease the sample securing and reliability of data, it was limited to general contractors receiving external audit from the government. The study samples are divided into a bankrupt company group and a non-bankrupt company group. The bankruptcy, insolvency, declaration of insolvency, workout and corporate reorganization were used as selection criteria of a bankrupt company. A company that is not included in the selection criteria of the bankrupt company group was selected as a non-bankrupt company. Accordingly, the study sample is composed of a total of 112 samples and is composed of 48 bankrupt companies and 64 non-bankrupt companies. A financial ratio was used as early predictors for development of an estimation model. A total of 90 financial ratios were used and were divided into growth, profitability, productivity and added value. The MDA (Multivariate Discriminant Analysis) model and BLRA (Binary Logistic Regression Analysis) model were used for development of bankruptcy prediction models. The MDA model is an analysis method often used in the past bankruptcy prediction literature, and the BLRA is an analysis method capable of avoiding equal variance assumption. The stepwise (MDA) and forward stepwise method (BLRA) were used for selection of predictor variables in case of model construction. Twenty two variables were finally used in MDA and BLRA models according to timing of bankruptcy. The ROC-Curve Analysis and Classification Analysis were used for analysis of prediction performance of estimation models. The correct classification rate of an individual bankruptcy prediction model is as follows: 1) one year ago before the event of bankruptcy (MDA: 83.04%, BLRA: 93.75%); 2) two years ago before the event of bankruptcy (MDA: 77.68%, BLRA: 78.57%); 3) 3 years ago before the event of bankruptcy (MDA: 84.82%, BLRA: 91.96%). The AUC (Area Under Curve) of an individual bankruptcy prediction model is as follows. : 1) one year ago before the event of bankruptcy (MDA: 0.933, BLRA: 0.978); 2) two years ago before the event of bankruptcy (MDA: 0.852, BLRA: 0.875); 3) 3 years ago before the event of bankruptcy (MDA: 0.938, BLRA: 0.975). As a result of the present research, accuracy of the BLRA model is higher than the MDA model and its prediction performance is improved.

  • PDF

Development of Korea eCall System and Effects Analysis through Integrated Demonstration (한국형 eCall 시스템 개발 및 통합실증을 통한 기대효과 분석)

  • Sangheon Kim;Youngsung Cho;Sunwoo Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.1
    • /
    • pp.61-81
    • /
    • 2024
  • eCall system assists traffic accident victims by connecting emergency rescue institutions with accurate accident information, helping them to identify the on-site situation in the event of a traffic accident. The purpose of this paper is to develop a Korean eCall system that reflects the requirements of domestic emergency rescue institutions and to analyze the expected effects through an integrated demonstration. The results of an integrated demonstration indicated that the communication success rate between the eCall IVS and the call center was 99.25%, and the average location information error was 1.2 m. In particular, it has been confirmed that the average location information error is less than 21.6 meters, as assessed by the Korea Communications Commission when evaluating the accuracy of domestic emergency rescue location information. When the eCall system was introduced, it was confirmed that the time from traffic accidents to hospital arrival could be shortened by 3 m 38 s for highways and 1 m 22 s for general roads. By it to traffic deaths from 2005 to 2022, it was analyzed that the number of fatalities decreased by 82,662, resulting in a reduction of approximately social costs.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.