항공기 탑재용 카메라 위치출력오차 측정방안 연구 (A Study of Test Method for Position Reporting Accuracy of Airborne Camera)

  • 송대범;윤용은
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

A Tape Feeder Inspection System for Measuring Feeding Accuracy

  • Cho, Tai-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.98.4-98
    • /
    • 2001
  • A tape feeder of a SMD(Surface Mount Device) mounter is a device that sequentially feeds electronic components on a tape reel to the pick-up system of the mounter. As components are getting much smaller, feeding accuracy of a feeder becomes one of the most important factors for successful component pick-up. Therefore, it is critical to keep the feeding accuracy to a specified level in the assembly and production of tape feeders. This paper describes a tape feeder inspection system that was developed to automatically measure and inspect feeding accuracy using machine vision. It consists of a feeder base, an image acquisition system, and a personal computer. The image acquisition system is composed of CCD cameras with lens ...

  • PDF

로봇의 위치 정밀도 측정을 위한 LTS의 설계 및 제작 (Design and Manufacture of Laser Tracking System for Measuring Position Accuracy of Robots)

  • 황성호;이호길;최령락;송웅희;김진영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.434-434
    • /
    • 2000
  • It is the main problem to measure the position and orientation of a robot end effector for the calibration of robots. The calibration methods can be used as a tool to improve the accuracy of robots without change of the arm or control architecture of robots. But such calibration methods require the accurate measurements. Dynamic measurement of position and orientation Provides a solution of this problem and improves dynamic accuracy by dynamic calibration o( robots. This paper describes the development o( the laser tracking system capable of determining the static and dynamic performance of industrial robots. The structure and system components are presented and basic experimental results are included to demonstrate the instrument performance. The system can be applied to the remote controlled mobile robots as weil as the calibration of robots.

  • PDF

NC 공작기계의 운동정도 측정에 관한 연구(제2보) -머시닝 센터의 직선 사이클 위치결정정도 측정에 관하여- (A study on Measuring of Motion Accuracy of NC Machine Tools(No. 2) - about Measuring of Linear Cycle Positioning Accuracy of Machining Center -)

  • 김영석
    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.51-51
    • /
    • 1998
  • It is very important to test linear cycle positioning accuracy of Machining centers as it affect all other machines machined by them in industries. For example, if the linear positioning accuracy of each axes directions is bad, the size of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper, measuring systems are organized to measure linear displacements of table or spindle of machine center using laser interferometer, magnescale and tick pulses comming out from computer in order to get data at constant time intervals from the sensors. And each set of data gotten from test is expressed to a plots by computer treatment and the results of linear positioning error motion is estimated to numerics by statistical treatments.

우량계 개발과 측정 오차 (Development of Rain Gauge and Observation Error)

  • 김대원;이부용
    • 한국환경과학회지
    • /
    • 제11권10호
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

Accuracy Measures of Empirical Bayes Estimator for Mean Rates

  • Jeong, Kwang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • 제17권6호
    • /
    • pp.845-852
    • /
    • 2010
  • The outcomes of counts commonly occur in the area of disease mapping for mortality rates or disease rates. A Poisson distribution is usually assumed as a model of disease rates in conjunction with a gamma prior. The small area typically refers to a small geographical area or demographic group for which very little information is available from the sample surveys. Under this situation the model-based estimation is very popular, in which the auxiliary variables from various administrative sources are used. The empirical Bayes estimator under Poissongamma model has been considered with its accuracy measures. An accuracy measure using a bootstrap samples adjust the underestimation incurred by the posterior variance as an estimator of true mean squared error. We explain the suggested method through a practical dataset of hitters in baseball games. We also perform a Monte Carlo study to compare the accuracy measures of mean squared error.

2차원 프로브에 의한 NC공작기계의 운동정밀도 측정 -제 1보 원호보간운동 정밀도 측정- (Measurement of motion accuracy by two-dimensional probe on NC machine tools -1st report, Measurement of the circular motion accuracy-)

  • 전언찬;소산전중덕;제정신
    • 한국정밀공학회지
    • /
    • 제13권3호
    • /
    • pp.56-62
    • /
    • 1996
  • This paper presented a new measuring system to improve circular motion accuracy by using two-dimensonal probe and master ring for NC machine tools. This measuring system reduced the circular motion error conspicuously by eliminating the influence of the acceleration/deceleration range and compensating the friction force whose influences were significant while measuring the motion. Experimental results show that this system had enough accuracy to measure a circular motion for NC machine tools, compared with the circular test method and the r .theta. method.

  • PDF

효율적인 비디오 유사도 측정을 위한 휘도 투영모델 (Luminance Projection Model for Efficient Video Similarity Measure)

  • 김상현
    • 융합신호처리학회논문지
    • /
    • 제10권2호
    • /
    • pp.132-135
    • /
    • 2009
  • 비디오 데이터들의 효율적 색인과 검색을 위해서는 비디오 시퀀스의 유사도 측정방법이 매우 중요한 요소이다. 본 논문은 비디오 시퀀스에 대한 효율적인 유사도 측정을 위해 휘도 성분 투사법을 제안한다. 기존의 알고리즘들이 히스토그램, 윤곽선, 움직임등과 같은 특성을 사용한 반면 본 논문에서 제안한 알고리즘은 휘도 성분을 투사하는 방법을 사용하여 비디오 유사도 특성을 효율적으로 나타낼 수 있다. 비디오 데이터의 효율적인 색인과 계산량 감소를 위해 누적된 유사도에 의해 추출된 키프레임들을 이용하여 비디오 시퀀스의 유사도를 구하고 수정된 하우스도르프 거리를 사용하여 키프레임 묶음들의 유사도를 측정하였다. 실험결과 제안한 휘도투시법을 사용한 비디오 색인 기법이 유사도 특성에서 기존의 특성을 사용한 방법에 비해 확연한 정확도 및 성능 차이를 보였다.

  • PDF

Accuracy Improvement of Stereo-Based Distance Measurement for Close Range Vessel Positioning

  • Ogura, Tadashi;Mizuchi, Yoshiaki;Kim, Young-Bok;Choi, Yong-Woon
    • 동력기계공학회지
    • /
    • 제19권2호
    • /
    • pp.27-32
    • /
    • 2015
  • This paper describes a distance measurement system with high accuracy that utilizes a stereo-based camera and a pan-tilt unit for automatically maintaining the positional relationship between a vessel and a target on the side of a facility at a close range. The measurement system offers an advantage in that it can measure the distance to a target while tracking it. In order to improve the ability to control the position of a vessel between it and a target while maintaining the distance especially at a close range, the accuracy of the measurement system has to be improved. The accuracy of the distance measured by our system is increased with revisions of the conclusively generated data of distance measurement. We verified the accuracy of our system from an experiment, which generated results that had an accuracy of 30 mm for distances in the range between 2-8 m.

Analysis of the effects of the baseline length accuracy in integer ambiguity resolution for GPS attitude determination system

  • Lee, Geon-Woo;Son, Seok-Bo;Park, Chan-Sik;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1211-1215
    • /
    • 2005
  • In the GPS attitude determination system, the baseline length constraints can be used efficiently to reduce the search space. It is possible by adopting the assumptions that the baseline length doesn't change and the true baseline length is precisely known. But in real situation, the baseline length might be changed by many reasons and it is impossible to measure the true baseline length because there exists measurement error and antenna phase centre movement. In order to analyze the effect of the baseline length accuracy, one needs to know the relation between the accuracy of the baseline length and success rates of the integer ambiguity resolution. In this paper, the effect of the baseline length accuracy to the integer ambiguity resolution in the attitude determination system is analyzed by empirical method. The results show that the margins in the baseline length accuracy is less than a few cm which implies that one should take great cares when applying the attitude determination system to the flexible structures.

  • PDF