• Title/Summary/Keyword: Accident Analysis Device

Search Result 112, Processing Time 0.02 seconds

A study on Cause Analyses of Fatal injuries by the Mobile Cranes (이동식 크레인 사고사망재해 심층분석 연구)

  • Shin, Woon-chul;Yeo, Hyun-Wook;Kwon, Jun-hyuck;Yi, Kwan-Hyung
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • In this study, the current regulations to be adequate in industrial site have to be renew in order to prevent the fatal injuries by mobile cranes. Fatal injury analyses were conducted with several accident cases by the mobile cranes. For each accident, the causes of the injuries were examined and proper safety measures were proposed. This study proposed a revision of the standard guideline as an accident prevention measures through in-depth analysis of fatal accidents. First, fatality rate per 10,000 persons by the mobiles cranes was 0.57 in 2011. Second, the in-depth analysis of the mobile crane accidents showed that the main factors of the accidents were the overturn of mobile crane, the fracture of connection part between mobile crane boom and rope, the breaking of rope and the misunderstanding over the signal between a mobile crane driver and workers around a mobile crane. Third, the order of high defection of connecting parts was bucket bolt, bracket and extension parts. Fourth, since there were several cases of overturn of mobile crane by itself in the in-depth analysis of the mobile crane, the over slop-proof device was proposed as the main alternative in this study. Fifth, the revision of standards of safety factor that shall be more than 10, of connecting parts of mobile crane was proposed.

Behavior Analysis of Elevator Door (엘리베이터 도어의 거동해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.991-994
    • /
    • 2007
  • Recently, there has been major issue in safety of elevator. In the view of safe management of elevator, the corresponding research must be done since accidents related elevator include not only actual accident but also possible accident in order to protect user from dangerousness. This research aims to seek an analytical solution for safety apparatus which caused accident again and again among dangerous factors of an elevator. In order to assure safety of door, ANSYS, a commercial software was applied and evaluate safety qualitatively by calculating stress and strain deformed under the loads of 40 to 100kg.

  • PDF

On the Safety Management Scheme for Industrial Accident Prevention (산업재해예방을 위한 안전관리방안)

  • 천명섭;정조영
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.11 no.18
    • /
    • pp.81-96
    • /
    • 1988
  • This study was aimed to propose a safety management scheme for industrial accident prevention, which has been increasingly embossed by industrialists and authorities concerned. A particular attention has been paid to the integrated ideas and practices to be needed in the field supervision. For this, a primary perspective of the study was drawn from the significant analysis of the current industrial accidents. From this observation, the researcher assumed that the integrated scheme should be an extension to the scientific approach in order to overcome various industrial accidents. The researcher also tried to provide more detailed information in each divisions. i.e., an essential safety device, an occupational disease, an educational practice. In this paper, the researcher will show in a first step how industrial accident prevention can contribute to progress of industrial peace and safety. Finally, the researcher emphasized that more investments would be highly profitable to industrial accident prevention and we should be in realization that all of activities in safety management are to be the main key in labour-management cooperation.

  • PDF

A Study on the System for Improving the Safety Device of the Hydrogen Fluoride ISO Tank (AHF ISO Tank의 안전성 향상을 위한 안전장치에 관한 연구)

  • Park, Sang Bae;Lee, Chang Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.54-62
    • /
    • 2020
  • Watching the leakage accident of the Gumi Hube Global AHF(Anhydrous fluoric Acid), I experienced how much chemical accidents affect on our society. Since then, many studies have been conducted on chemical accident in many fields. The use department wanted to find improvement plans for the process system and apply them to the field. The safety field wanted to study improvement of safety through the analysis of damage effects and apply them to emergency response to reduce damage effects. In this study, Mechanical safe devices have been applied which can respond quickly to chemical accidents occurring during the charging operation to enhance the safety of the AFH ISO Tank(Anhydrous fluoric Acid International Organization for Standardization Tank). Investigation of similar tanks confirmed that other chlorine tanks with the same working procedure as AHF ISO Tank have a mechanical safety device, EFV(Excess Flow Valve). Applicability and performance for emergency shutdown when EFV is introduced in AHF ISO Tank can be verified by comparing and examining the accident situation of Hube Global Accident and the accident in Ulsan 2018. Comparing accident cases, expected performance and applicability, It is suggested that EFV, a mechanical safety device that can reduce damage from chemical accidents to the tank and handle accidents early, should be introduced to the tank.

A Study on Analysis between Accidents Caused by Human Errors and Personal Characteristics of Railway Drivers (철도기관사들의 개인적 특성과 인적오류사고 발생에 대한 비교 분석)

  • Yum, Byeoung-Soo;Gal, Won-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.85-91
    • /
    • 2012
  • To verify the effect of driver's personal characteristics of driver on the accident frequency through railway accidents caused by human errors and the relationship with aptitude test. To prove the relevance between the driver's personal characteristics and human error accidents. Accident data from 2010 to 2011 was analyzed which collected from a train crew department in K national corporation, and 31 drivers gave an personal interview from Sep. 2011 to Nov. 2011 who had controlled a train alone and caused an accident. Compared between driver's personal characteristics and accident rate, and accident induction possibility surveyed from normal person and disqualified in aptitude tests. Accidents was occurred with the age 40s (27%) and 50s (25%), and with the experience between 15 years and 20 years (38%) and over 20 years (30%). Because more aged, more experienced, it can be seen in the correlation between driver's age and accidents induction caused by human errors like illusion. First of all it must be checked whether working conditions and environmental factors are human error-prone. Most accidents occur when received civil complaints or manager at the riding. Therefore accidents can be prevented when investigated through subsequent surveys how often human error happens, even though no accident, and safety device installed based on the error frequency.

Development of MAC layer of Network for KTX high-speed train system (고속 열차용 네트워크의 MAC 계층 개발)

  • Lee, Bum-Yong;Kim, Hyung-In;Jung, Sung-Youn;Park, Jae-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2015-2020
    • /
    • 2008
  • Real-time communication network is important for KTX high speed train system because small problem can make a huge accident. Communication network for KTX high speed train system consists of IEEE 802.4 token bus network and FM0 encoding. The network device is developed by using MC68824 TBC, MC68185 TPM and MC68020 MPU. The network device make available to analysis of the network protocol among vehicles for Kyung-Boo high-speed train system.

  • PDF

Improvement of Obstruction Detecting Method at Railroad Crossing by Image Analyze (영상해석을 통한 철도건널목 장애물 검지방법 개선)

  • Song, Hyeon-Sam;Kim, Young-Dal;Lee, Dae-Dong;Shim, Jae-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1444-1450
    • /
    • 2011
  • An analysis of the causes of railroad crossing accidents reveals that most train collision accidents that occur when safety crossing devices are functioning normally occur because vehicles either experience engine failure on the tracks or because drivers were not notified of the coming train, in which case they get trapped on the tracks when the crossing barriers descend. To prevent such an accident, obstacle detection device by using laser beams detecting the presence of obstacle and crossing bar direction controller by moving direction detection sensor using the Earth's magnetic field detection technology are used in the railroad crossing. Despite using the obstacles detector and crossing bar direction controller in the railroad crossing, the equipments for the railroad crossing does not prevent accidents completely. Therefore, this research has studied new method that can detect obstacles through image analyze and alternate existing equipments. There will be excellent effect to be preventing railroad crossing accident by developing a reliable and new obstacle detecting device.

Quantitative Risk Assessment based on Fault Tree Analysis for Gangform Accident (갱폼 재해의 FTA를 통한 정량적 위험성 산정에 관한 연구)

  • Ham, Young Jong;Kee, Jung Hun;Park, Jong Yil
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.40-47
    • /
    • 2020
  • Although gangform has good workability due to the integration of outer wall forms and working platforms, 22 workers were died from 21 gangform related accidents during 2012 to 2016. Quantitative risk assessment is required for evident based prevention measure selection. In this study, based on 52 accident data from 2004 to the first half of 2019, FTA is conducted for probabilities of direct causes and their contribution to accidents. Three stages are considered; gangform installation, dismantling and lifting, and using. The effectiveness of countermeasures is evaluated through minimum cut set, RAW and RRW. Complete assembly of gangform on the ground level, detailed planning, and fall prevention device are suggested as prevention measures for installation, dismantling and lifting, and using stages, respectively.

A Study on the Hydraulic Fall Prevention Device (유압식 추락 방지장치에 관한 연구)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Huh, Yong;Chang, Sung-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.78-83
    • /
    • 2010
  • Since a tower crane is too high for a worker to ascend and by the wind in the high altitude, the possibility of a safety accident is very high, a lift assist is used. In this study, the hydraulic fall prevention device using the pressure generation device by Seok, et al. was developed. For this, the effects on the fall prevention performances of factors such as gear clearance, oil viscosity, rotative velocity and so on were evaluated by the analysis of fluid flow using FEM and the prototype was producted and a function test was performed.

Analysis of Electrical Accident for Outlet Circuit of Laboratory on ETA (ETA를 통한 연구실험실 콘센트회로의 전기재해 분석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Park, Jong-Young;Kim, Sang-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.27-33
    • /
    • 2017
  • This study is intended to identify issues on the basis of investigating the actual state of laboratory environment and outlet circuit, and derive end states by expressing sequences from the initiating event of disaster to accident in leakage current, poor contact and overload through ETA(event tree analysis). To this end, this study investigated the actual state of electric equipment of laboratory at universities in all parts of country. And it is shown that most of them are failure in electric work and user negligence in the investigation of actual state. It is found that there is earth fault and defect in wire diameter in the failure of electric work and the problem of partial disconnection due to wire bundling and poor contact in user negligence. Outlet-related component, failure rate and initiating events are composed of a total of 41 initiating events, i.e., 30 internal initiating events and 11 external initiating events. And end states are composed of a total of 15 parts, i.e., 3 electric power parts and 12 safety parts. Earthing class 3 is the most important safety device against leakage current (initiating event). And in case of poor contact, it is necessary for manager to check thoroughly because there is no safety device. In case of overload/overcurrent, when high-capacity equipment is connected, a molded case circuit breaker, safety device, worked. However, in most cases, it is verified that this doesn't work. This study can be utilized as electric equipment safety guide for laboratory safety manager and managers.