• Title/Summary/Keyword: Accident Analysis Device

Search Result 112, Processing Time 0.023 seconds

A Proposal for Unit Testing Procedure of Embedded Software Complied with Safety Assessment Criteria (안정성평가 기준에 적합한 내장형 소프트웨어 단위시험 절차 방안)

  • Jang, Jeong-Hoon;Lee, Won-Taek;Jang, Ju-Su
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2223-2231
    • /
    • 2010
  • Recently, an important physical device of transportation, such as car, railroad, ship and aircraft has changed into electronic control unit. According to accident reports, the most of car accidents are caused by faults of embedded software loaded to computer control unit. The facts implies that the test to find defects in embedded software haven't performed sufficiently. As a result, it is necessary to establish the test procedures of embedded software based on safety assessment criteria. The objective of this proposal is to provide a unit test procedure complied with the safety assessment criteria for the embedded software. In addition, an effective unit testing procedure and defect analysis methods are proposed and a testing procedure using a safety criteria built-in tool is presented.

  • PDF

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

Analysis of the Characteristics of Flue Gas in Infrared Mobile Heaters for Gas Room Heating (가스난방용 적외선 히터의 연소배기가스 특성해석)

  • Kim Young-Gyu;Kwon Jeong-Rock;Kim Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.66-73
    • /
    • 1998
  • This paper deals with the combustion characteristics of flue gas in infared mobile heaters. The experimental work has been performed to obtain the concentration levels and combustion characteristics of flue gas with varying chamber size and room temperature. The experimental results showed that oxygen depletion sensor device was operated at the oxygen concentration level of $18.3\%$ for all the chamber size. The combustion characteristics of oxygen and carbon dioxide show a linearity After 10 minutes the combustion property of carbon monoxide occurs at random without a level of oxygen and carbon dioxide in closed space of the heater. In these results, it is very important to prevent incomplete combustion through a sufficient ventilation, and accident prevention with a reduction of the oxygen and diffusion of toxic carbon monoxide.

  • PDF

A study on the toilet lifting seat for the elderly (노약자를 위한 변기 리프팅 시트 연구)

  • Minseo Kim;Hyemin Son;Jinho Cho;Sang-Hyun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.459-464
    • /
    • 2024
  • The purpose of this study is to design a toilet lifting seat to prevent falls accidents in the elderly while using the toilet. Prior to design, laws and national standards related to restroom use were investigated and the available space for the assistive devices to be installed was determined. In additions, considering the body size and operating range of the elderly, the optimal final position of the toilet seat is set so that users can use it more safely and conveniently without external help. Moreover, in order to provide an effective standing assistance function, a complex 4-bar link structure was applied to enable simultaneous seat elevation and angle adjustment when operating the device, and the appropriate link shape and dimensions were determined using a linkage program and UG NX. FEA analysis using ANSYS Workbench is performed to ensure the robustness of the stretched linkage and the feasibility of the lifting seat is verified through fabrication.

A Study on Protection Method of Energy Storage System for Lithium-ion Battery Using Surge Protection Device(SPD) (SPD를 이용한 리튬이온전지용 전기저장장치의 보호방안에 관한 연구)

  • Hwang, Seung-Wook;Lee, Hu-Dong;Tae, Dong-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.568-574
    • /
    • 2020
  • Recently, the installation of energy storage systems (ESSs) that have a range of functions, such as power stabilization of renewable energy sources, demand control, and frequency regulation, has been increasing annually. On the other hand, since the fire accident of ESS occurred at Gochang Power Test Center in August 2017, 29 fire accidents with significant property losses have occurred, including the Gyeongsan substation and Kunsan PV power plant. Because these fire accidents of ESS are arisen regardless of the season and capacity of ESS, an analysis of the fault characteristics in ESS is required to confirm the causes of the fire accidents accurately and ensure the safety of the ESS. This paper proposes the modeling of ESS using PSCAD/EMTDC S/W to identify the fault characteristics and ensure the safety of the ESS. From the simulation results of fault characteristics based on various scenarios, it is clear that the insulation of ESS may be breakdown due to the largely occurring CMV (common mode voltage). Furthermore, the CMV between the PCS and battery can be reduced, and the insulation breakdown of ESS can be prevented if an SPD (surge protect device) is installed in the battery and PCS sides, respectively.

An Interactive Method between HSE System and Wearable Components through Analysis on Risk Scenarios (위험 시나리오 분석을 통한 스마트 HSE 시스템 및 웨어러블 컴포넌트 연동방안)

  • Shon, DongKoo;Lim, Dong-Sun;Im, Kichang;Park, Jeong-Ho;Kim, Jong-Myon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.5
    • /
    • pp.407-416
    • /
    • 2018
  • The development of modern technology has rapidly grown the field of wearable devices. Wearable equipments should satisfy low power consumption and small/lightweight because of characteristics of body wearing. In this paper, an overview of wearable equipments is explained, and wearable device market is investigated. In addition, we investigate developed technology of wearable components, which is divided into component and communication technology. Meanwhile, a smart HSE system is required to meet the demand of the society for the serious industrial accident. To address this issue, we propose an interactive method between the wearable component and the HSE system, which are expected to be effective in safety management. As a detailed case study, a risk scenario is made with risk factors in welding workshop, and then we propose an interactive method between a wearable component and an HSE system that can reduce the risk. This proposed method is useful to achieve high level of worker's safety.

Crashworthiness Study of Sliding Post Using Full Scale Crash Test Data (충돌실험 데이터를 이용한 슬라이딩 지주구조의 감충성능 분석)

  • Jang, Dae-Young;Lee, Sung-Soo;Kim, Kee-Dong;Sung, Jung-Gon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Medium to large post structures installed along the roadside without proper protection can lead to serious vehicle damage and occupant injury at the impact. In North America and Europe, splitting systems such as slip base or breakaway device are used to reduce impacts. But the system has the risk of secondary accident when the splitted post falls down to the traffic or pedestrian. Sliding Post have been proposed as a way to solve this problem. By studying the crash test results of the 1.3ton and 0.9ton vehicle with 60 km/h and 80 km/h to a Rigidly Fixed Post (RFP) and Sliding Post (SP), danger of the conventional RFP and crashworthiness of the SP have been proven. While collision analysis only from the acceleration measured at the center of the vehicle assumes the motion of the post is the same as that of the vehicle, in this paper, by adding high speed film data to the analysis with vehicle acceleration could have separate the post motion from the vehicle motion. It gives better explanations on the movement of post and vehicle in each distinctive time step and provides basics to the crashworthy post design.

Evacuation safety analysis depending on the type of subway platform and ticket barrier (지하철 승강장과 개찰구 유형별 대피안전성 분석)

  • Park, Byoung-Jik;Park, Il-Gyu;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.237-242
    • /
    • 2015
  • With the rapid development of modern society, subway has become one of the most typical urban transport systems. Since fire accident occurred at Daegu subway in 2003, importance of life safety and disaster prevention have been widely recognized and many studies have been carried out. As a result of these studies, fire-retardant and non-combustible interior material and platform screen door with passenger guide indication device have been developed, but studies on a subway evacuation criteria have been in a stalemate. Therefore, this study is intended to improve the subway evacuation standard. It is very difficult to take into account whole subway system, so a typological approach to a ticket was carried out referring to previous studies focused on a subway platform. this paper selected the most common subway platforms and estimated evacuation time among 10 platforms from previous studies and 8 from this study. As a result, evacuation time exceeded 6 minutes which is the guideline of existing standard. Therefore, it is necessary to update the standard for evacuation time and add supplementary conditions which can help establishing the measures for safety facilities and prevention measures.

A study of flour dust explosion (사료분진의 폭발특성에 관한 연구)

  • Lee, Hong-Ju;Woo, In-Sung;Hong, Hyun-Kyoung;Sa, Min-Hyung;Kim, Yun-Seon;Hwhag, Myung-Whan;Hwang, Seong-Min;Park, Hee-Chul;Lee, Ju-Yup
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.4
    • /
    • pp.109-116
    • /
    • 2011
  • This study examined into property of flour dust explosion to get the basic data for safety of industry by protecting accident of dust explosion. The experiment was conducted to know the effect of distance between explodes in the experiment device, effect of flour dust concentration, effect of humidity, effect of explosion pressure to the dust concentration and effect of inactive substance additive. The study indicated that explosion was happened effectively at the optimum distance 100mm or less in inter-polar distance, and minimum ignition energy was measured at 6mm. The data of feed concentration to the probability of explosion showed that the smaller the particle diameter was, the larger probability of explosion was, and the higher the dust concentration was, the more increased the pressure of explosion was, but more than upper limit of dust concentration, then the explosion of pressure decreased. For the effect of humidity, the more it contained water, the more decreased the ignition energy of dust was, so increased minimum explosive concentration, and effective water content was minimum 10% or more. Inactive substance additive was effective in adding more than 15% CaCO3 and CaO as substance inhibiting dust explosion, in which CaCO3 was more effective than CaO. the analysis of the flame of dust explosion was performed by high-speed video camera, it showed the size of flame bacame smaller in order that sub feed, main feed, wheat powder. As a result, sub feed was expected to be less dangerous than others.

Development and Application of Siphon Breaker Simulation Program (사이펀 차단기 시뮬레이션 프로그램의 개발 및 활용)

  • Lee, Kwon-Yeong;Kim, Wan-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.346-353
    • /
    • 2016
  • In the design conditions of some research reactors, the siphon phenomenon can cause continuous efflux of water during pipe rupture. A siphon breaker is a safety device that can prevent water efflux effectively. However, the analysis of the siphon breaking is complicated because many variables must be included in the calculation process. For this reason, a simulation program was developed with a user-friendly GUI to analyze the siphon breaking easily. The program was developed by MFC programming using Visual Studio 2012 in Windows 8. After saving the input parameters from a user, the program proceeds with three steps of calculation using fluid mechanics formulas. Bernoulli's equation is used to calculate the velocity, quantity, water level, undershooting, pressure, loss coefficient, and factors related to the two-phase flow. The Chisholm model is used to predict the results from a real-scale experiment. The simulation results are shown in a graph, through which a user can examine the total breaking situation. It is also possible to save all of the resulting data. The program allows a user to easily confirm the status of the siphon breaking and would be helpful in the design of siphon breakers.