• 제목/요약/키워드: Accelerated Degradation

검색결과 514건 처리시간 0.033초

유동가속부식이 잠재한 곡관내의 3차원 난류유동 해석 (Three-dimensional Turbulent Flow Analysis in Curved Piping Systems Susceptible to Flow-Accelerated Corrosion)

  • 조종철;김윤일;최석기
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.900-907
    • /
    • 2000
  • The three-dimensional turbulent flow in curved pipes susceptible to flow-accelerated corrosion has been analyzed numerically to predict the pressure and shear stress distributions on the inner surface of the pipes. The analysis employs the body-fitted non-orthogonal curvilinear coordinate system and a standard $ {\kappa}-{\varepsilon}$ turbulence model with wall function method. The finite volume method is used to discretize the governing equations. The convection term is approximated by a high-resolution and bounded discretization scheme. The cell-centered, non-staggered grid arrangement is adopted and the resulting checkerboard pressure oscillation is prevented by the application of a modified version of momentum interpolation scheme. The SIMPLE algorithm is employed for the pressure and velocity coupling. The numerical calculations have been performed for two curved pipes with different bend angles and curvature radii, and discussions have been made on the distributions of the primary and secondary flow velocities, pressure and shear stress on the inner surface of the pipe to examine applicability of the present analysis method. As the result it is seen that the method is effective to predict the susceptible systems or their local areas where the fluid velocity or local turbulence is so high that the structural integrity can be threatened by wall thinning degradation due to flow-accelerated corrosion.

  • PDF

가속화 시험을 통한 페놀폼 단열재의 장기성능 비교분석에 관한 연구 (Study on Long-term Performance of Phenolic Foam Insulation through Accelerated Aging Test)

  • 김진희;김상명;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제40권2호
    • /
    • pp.11-23
    • /
    • 2020
  • The application of the high-performance insulation materials for buildings seems to be an essential measure for reducing energy use in buildings. Phenolic foam is a readily available insulation material with thermal conductivity of about 0.018 to 0.020 W/(mK). It has the advantage of higher thermal resistance and better fire resistance compared to other conventional building insulation materials. Insulation material used for building envelope is regarded as one of the decisive factors for building's energy load. Furthermore, the degradation of its thermal performance over time increasingly affects the building's energy use demand. Generally, the life span of conventionally built buildings is expected to be more than 50 years, so the long-term performance of insulation materials is critical. This paper aims to evaluate the long-term performance of phenolic form boards through an accelerated aging test. The tests were conducted according to BS EN 13166 and KS M ISO 11561. Based on the results of the accelerated aging test, the thermal performance variation of the material was analyzed, and then its aged value after 25 years was computed. Also, the characteristics of the phenolic foam board's long-term performance were also examined based on the standard testing methods adopted.

구조용 접착제의 열화 특성 연구 (Degradation Characteristics of Structural Adhesives)

  • 황영은;오진오;윤성호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.443-446
    • /
    • 2009
  • 본 연구에서는 기존의 접착제를 대체용 접착제로 대체 가능한지의 여부를 조사하기 위하여 구조용 접착제에 대해 일련의 열화 시험을 수행하였다. 구조용 접착제는 온도, 수분, 자외선 등의 자연환경 조건을 모사할 수 있는 가속노화시험기를 통해 복합적인 환경인자에서 1000시간 동안 노출시켰다. 구조용 접착제의 기계적 특성은 하중 시험기를 통해, 화학적 특성은 적외선 분광 분석 장치를 통해 평가하였다. 연구결과에 따르면 대체용 접착제가 환경인자에 노출될 경우 기존의 접착제에 비해 안정적이기 때문에 기존의 접착제는 대체용 접착제로 대체 가능할 것으로 판단하였다.

  • PDF

발전기 고정자 권선의 절연열화 메카니즘 분석 (Analysis of Insulation Aging Mechanism in Generator Stator Windings)

  • 김희동
    • 한국전기전자재료학회논문지
    • /
    • 제15권2호
    • /
    • pp.119-126
    • /
    • 2002
  • The mica/epoxy composite used in generator(rated 22 kV and 500 MW) stator windings was aged at 180$\^{C}$ for up to 1000 hours in air and hydrogen. The degradation mechanism was investigated through the defect of evolution and microstructural analysis by performing SEM(Scanning Electron Microscope). As the thermal aging time increases, the number of voids per unit volume increases at the mica/epoxy interface of generator stator windings. The aged specimens in hydrogen showed retarded generation and growth of voids. Accelerated aging tests were conducted using the combination of thermal and electrical aging in air and hydrogen. The aging was carried out at a combined stress such as thermal aging at 110$\^{C}$, electrical aging at 5.5 kV/mm and frequencies 420 Hz in air, and electrical aging at 5.5 kV/mm and frequencies 420 Hz in hydrogen (pressure 4 kg/㎠). Thermal and electrical aging generates large voids at the mica/epoxy interface in air. Electrical aging in hydrogen also generates small voids, delaminations and cracks in mica tapes.

원전 케이블용 절연재료의 열분석과 등가수명 (Thermal Analysis and Equivalent Lifetime Prediction of Insulation Material for Nuclear Power Cable)

  • 김지연;양종석;박경흠;성백용;방정환;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제29권1호
    • /
    • pp.17-22
    • /
    • 2016
  • The activation energy of a material is an important factor that significantly affects the lifetime and can be used to develop a degradation model. In this study, a thermal analysis was carried out to evaluate and collect quantitative data on the degradation of insulation materials like EPR and CSP used for nuclear power plant cables. The activation energy was determined from the relationship between log ${\beta}$ and 1/T based on the Flynn.Wall.Ozawa method, by a TGA test. The activation energy was also derived from the relationship between ln(t) and 1/T based on isothermal analysis, by an OIT test. The activation energy of EPR derived from thermal analysis was used to calculate the accelerated aging time corresponding to the number of years of use, employing the Arrhenius equation, and determine the elongation corresponding to the accelerated aging time.

가속노화에 따른 백색 연막수류탄(M8)의 화학적 구조 변화에 관한 연구 (A Study on Chemical Structure of White Smoke Grenade by Aging)

  • 박장호;조민수;김영대;이병택;장일호
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1186-1191
    • /
    • 2011
  • Composition which was used as a white smoke grenade consists of Aluminium(Al), Hexachloroethane(HCE) and Zinc Oxide(ZnO), etc. there is a possibility of misfire due to long term storage and there are very few reports on the mechanism behind misfire. In this study, an experimental method known as accelerated degradation testing is used to investigate the chemical mechanism resulting in misfire. The mechanism of chemical change during long term storage was analyzed with XRD and FT-IR. Analysis results suggest that a part of HCE consisting of the white smoke grenade disappeared and the other part was combined into $ZnCl_2$, $AlCl_3$, as a recycled intermediate product under closed system.

40-Gbps급 InGaAs 도파로형 포토다이오드의 신뢰성 실험 (Reliability testing of InGaAs Waveguide Photodiodes for 40-Gbps Optical Receiver Applications)

  • 주한성;고영돈;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.13-16
    • /
    • 2004
  • The reliability of 1.550m-wavelength InGaAs mesa waveguide photodiodes(WGPDs), which developed for 40-Gbps optical receiver applications, fabricated by metal organic chemical vapor deposition is investigated. Reliability is examined by both high-temperature storage tests and the accelerated life tests by monitoring dark current and breakdown voltage. The median device lifetime and the activation energy of the degradation mechanism are computed for WGPD test structures. From the accelerated life test results, the activation energy of the degradation mechanism and median lifetime of these devices in room temperature are extracted from the log-normal failure model by using average lifetime and the standard deviation of that lifetime in each test temperature. It is found that the WGPD structure yields devices with the median lifetime of much longer than $10^6$ h at practical use conditions. Consequently, this WGPD structure has sufficient characteristics for practical 40-Gbps optical receiver modules.

  • PDF

XLPE 절연체의 등가 및 가변온도 가속열화실험을 통한 기계적 특성 비교 분석 (A Comparison Study on Mechanical Properties of XLPE Insulation Thermally Degraded at Equivalent and Variable Temperature Conditions)

  • 김태준;황재상;정성훈;김태영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.73-77
    • /
    • 2022
  • Recently, as the number of years of operation has increased for more than 30 years, interest in evaluating the remaining life of major power facilities such as transformers and ultra-high voltage cables is increasing. In particular, the risk of failure is increasing because the underground transmission XLPE cable has been built since 1980 and has been operating in excess of 30 years of design life or close proximity. Therefore, it is necessary to develop an algorithm to evaluate the residual life of the XLPE cable considering the load to determine the risk of failure. Since load data is large amount of data, it is necessary to make the variable load information equivalent to the time unit first in order to calculate the remaining life of the system quickly. In overseas literature, transformers are reported to be standardized for variable load equivalent conversion formulas, but they have not been reported for ultra-high voltage cables. Therefore, in this paper, whether the equivalent conversion formula of a transformer can be applied to XLPE cables was reviewed through accelerated degradation tests under equivalent and variable temperature conditions, and considerations were studied when evaluating the remaining operating life of XLPE cables based on the experimental results.

A CONSIDERATION OF THERMODYNAMIC ASPECTS OF WEAR: ENERGY AND ENTROPY

  • Ling, F.F.;Bryant, M.D.;Doelling, K.L.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.219-220
    • /
    • 2002
  • To establish a thermodynamic basis for degradation, a hypothesis was made on the potential correlation between entropy and degradation for wear of machinery components. This paper reports an experimental study of wear of model machinery component pairs, on an accelerated testing basis. Measured were wear, friction, temperatures, and entropy flow. Results show a strong correlation between the referenced wear and the production of entropy flow. The hypothesis linking wear to entropy led to formulations consistent with the Archard/Holm wear law.

  • PDF

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.