• 제목/요약/키워드: Abutment surface

검색결과 182건 처리시간 0.02초

상악측절치 수복을 위한 Cantilever bridge (STRESS ANALYSIS ON THE ALVEOLAR BONE OF CANTILEVER BRIDGES REPLACING MAXILLARY LATERAL INCISOR)

  • 김형수;양홍서
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.303-316
    • /
    • 1993
  • The purpose of this study was to analysis the stress distribution induced by three unit PFM bridges and various cantilever bridges replacing maxillary latersal incisor. The simplified two-dimensional photoelastic models used for this study was contructed in the folio- wing way. CR/R ratio was designed to be 1 : 1, 1 : 1.25 and 1 : 1.5. The pontics of cantilever bridge supported by maxillary canines consisted of wrap-around type, rest-extension type, and simple type. 3-unit PFM bridge was constructed with traditional method. 1kg vertical static load was applied on the center of the incisal edge of the pontic. The stress pattern was examined and recorded by photography. The results obtained were as follows ; 1. The magnitude of stress on the abutment root apex area of a traditional 3-unit bridge was the lowest. 2. The model of cantilevered pontic with a rest showed the relatively well distributed stress around the abutment tooth. The model with simple pontic generated the greatest stress concentration in the supporting structure of the abutment tooth. 3. As the height of bone level reduced, the rotational and vertical force increased around the abutment tooth. 4. The stress concentration of the 3-unit bridges occured on the root apex and stress concentration of the cantilever briage occured on the root apex and cervix area, 5. In the case of the cantilever bridge, stress concentrated distally on the root apex area of the abutment tooth and additional stress was observed mesially on the upper part of the root. Especially in the case of the simple pontic, was phenomenon was more apparent than the others. 6. Force applied to cantilevered pontic was transmitted to the adjacent central incisor through the contact surface. Stress was markedly observed on the mesial cervix area in the case of simple pontic and on the root apex area in the case of wrap-around type and rest-extension type.

  • PDF

내부 원추형 연결형태 임플란트에서 지대주 나사머리의 좌면각도가 연결부 기계적 안정성에 미치는 영향 (Influence of bearing surface angle of abutment screw on mechanical stability of joint in the conical seal design implant system)

  • 김주현;허중보;윤미정;강은숙;허재찬;정창모
    • 구강회복응용과학지
    • /
    • 제30권3호
    • /
    • pp.206-214
    • /
    • 2014
  • 목적: 내부 원추형 연결형태 임플란트에서 지대주 나사의 좌면각도가 연결부의 기계적 안정성에 미치는 영향을 알아보기 위함이다. 연구 재료 및 방법: 원추형 연결구조 티타늄 임플란트와 시멘트 유지형 지대주, 텅스텐 카바이드 코팅된 티타늄 합금 지대주 나사를 사용하였다. 좌면각도가 $45^{\circ}$$90^{\circ}$를 갖는 지대주와 지대주 나사를 제작하여 30 Ncm 조임회전력으로 지대주를 체결한 후 하중을 가하고 체결 및 하중 부여에 따른 침하량을 측정하였다(n = 5). 유압식 피로시험기에 임플란트를 고정하고 스테인리스 스틸 금속관을 지대주에 합착하였다. 이 후 반복 하중을 가한 후 풀림토크 변화량을 측정하고, 압축굽힘강도와 피로강도를 측정하였다(n = 5). 결과: 지대주 침하량은 지대주나사 체결 시 가장 크게 나타났으며(P < 0.05), 나사체결과 하중부여에 따른 총 침하량은 $45^{\circ}$군보다 $90^{\circ}$군에서 더 크게 측정되었다(P < 0.05). 반복하중 부여 후 풀림 토크, 그리고 최대 압축굽힘강도와 피로강도는 통계적으로 유의한 차이를 보이지 않았다(P > 0.05). 결론: 본 실험조건하에서 지대주 나사머리의 원추형 설계가 지대주의 총 침하량을 약간 감소시키는 효과를 나타냈으나, 연결부의 전체적인 기계적 안정성에 미치는 영향은 크지 않을 것으로 판단된다.

티타늄 지대주와 비귀금속 합금사이의 갈바닉 부식에 의한 표면 거칠기 변화 평가 (Surface roughness changes caused by the galvanic corrosion between a titanium abutment and base metal alloy)

  • 이정진;송광엽;안승근;박주미
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.65-72
    • /
    • 2011
  • 연구 목적: 이 연구의 목적은 티타늄 지대주와 비귀금속 보철물이 접촉한 경우를 가정하여 이종 금속간 접촉에 의한 갈바닉 부식으로 인해 발생하는 표면 거칠기 변화를 비교, 평가하고자 하였다. 연구 재료 및 방법: 성분과 조성이 다른 3종의 Ni-Cr합금 (T3, Bella bond plus, Tilite)과 cp 티타늄 Grade 2를 이용하여 $13{\times}13{\times}1.5\;mm$의 크기로 시편을 각 군당 6개씩 제작하였다. 연마과정 후 절연 테이프로 직경 6 mm만을 노출시켜 potentiostat (Parastat 2273A)를 이용하여 동전위 분극 시험과 갈바닉 부식 시험을 시행하였으며, 표면 거칠기 측정기(Surftester SV-3000)를 이용하여 부식 전 후 거칠기를 평가하였다. 측정값을 paired t-test와 One-way ANOVA로 분석하였다. 결과: 티타늄과 접촉한 모든 Ni-Cr 시편의 표면 거칠기는 통계적으로 유의하게 증가하였다. 증가량은 베릴륨을 포함한 T3합금 ($0.016{\pm}.007\;{\mu}m$)이 가장 컸으며, 베릴륨을 포함하지 않은 Bella bond plus ($0.012{\pm}.003\;{\mu}m$), 티타늄을 첨가한 Tilite ($0.012{\pm}.002\;{\mu}m$)는 큰 차이를 보이지 않았다. 금속 종류에 따른 거칠기 증가는 유의한 차이를 보이지 않았다. 결론: 티타늄과 접촉한 비귀금속 합금은 갈바닉 부식에 의해 표면 거칠기가 증가하였다.

A STUDY ON MECHANICAL PROPERTIES OF TiN, ZrN AND WC COATED FILM ON THE TITANIUM ALLOY SURFACE

  • Oh, Dong-Joon;Kim, Hee-Jung;Chung, Chae-Heon
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.740-750
    • /
    • 2006
  • Statement of problems. In an attempt to reduce screw loosening, dry lubricant coatings such as pure gold or tefron have been applied to the abutment screw. However, under repeated tightening and loosening procedures, low wear resistance and adhesion strength of coating material produced free particles on the surface of abutment screw and increased frictional resistance resulting in screw tightening problems. Purpose. The aim of this study was to compare friction coefficient, adhesion strength, vickers hardness and evaluate coating surface of titanium alloy specimens coated with TiN(titanium nitride), ZrN(zirconium nitride) and WC(tungsten carbide). Material and method. Titanium alloy(Ti-6Al-4V) discs of 12mm in diameter and 1mm in thickness divided into 4 groups. TiN, ZrN and WC was coated for the specimens of 3 groups respectively, and those of 1 group were not coated. Each group was made up of 4 specimens. In this study, sputtering method was used among the PVD(Physical Vapor Deposition) techniques available for TiN, ZrN and WC coatings. Friction coefficient, adhesion strength, vickers hardness and coating surface of 4 groups were measured. Results. 1. For all three coating conditions, friction coefficient was significantly decreased. Especially, ZrN coated surface showed the lowest value. $TiN(0.39{\pm}0.02)$, $ZrN(0.24{\pm}0.01)$, $WC(0.31{\pm}0.03)$. 2. TiN coating showed the highest adhesion strength, however ZrN coating had the lowest value. $TiN(25.3N{\pm}1.6)$, $ZrN(14.8N{\pm}0.6)$, $ WC(18.4N{\pm}0.7)$. 3. Vickers hardness of all three coatings was remarkably increased as compared with that of none coated specimen. TiN coating had the highest Vickers hardness, however WC coating showed the lowest value. $TiN(1865.2{\pm}33.8)$, $ZrN(1814.4{\pm}18.6)$, $WC(1008.5{\pm}35.9)$. 4. The ZrN or WC coated specimen showed a homogeneous and smooth surface, however the rough surface with defects was observed for TiN coating. Conclusions. When TiN, ZrN and WC coating applied to the abutment screw, frictional resistance would be reduced, as a result, the greater preload and prevention of the screw loosening could be expected.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.

완전 도재관의 선택 (Selection of all ceramic crown)

  • 이승규
    • 대한심미치과학회지
    • /
    • 제24권2호
    • /
    • pp.122-133
    • /
    • 2015
  • 성공적싱 완전도재관 치료를 위한 요구조건은 통상적 치료와 크게 다르지 않다. 적절한 치아삭제, 임시치아, 및 정확한 최종인상이 중요하다. 그럼에도 불구하고 차별점은 본딩에 있다. 수복물 내면과 지대치 외면에 레진시멘트를 도포하는 것 이외에도 본딩 술식은 비생활치의 포스트 코어 치료에도 적용할 수 있다. 생활치 지대치는 비생활치보다 심미와 기능 면에서 성공을 거두기가 더 쉽다. 포스트 코어 본딩 술식은 비생활치 지대치의 장기 성공에 중요한 역할을 한다. 본 논문에서 완전 도재관의 성공 전략 중에서 포스트 코어 축성 및 완전 도재관 본딩에 관하여 임상적 경험을 나누고자 한다.

임플란트 지대주 삭제시의 발생열에 관한 연구 (A Study on the heat generation during implant abutment preparation)

  • 이호진;송광엽;장태엽
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

3차원 컴퓨터 그래픽 기술을 이용한 KONUS 내관의 설계와 제작 (DESIGN AND FABRICATION OF INNER KONUS CROWN USING THREE DIMENSIONAL COMPUTER GRAPHICS)

  • 김인섭;김병오;유관희;강동완
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.544-551
    • /
    • 2000
  • A fabrication method of inner and outer crown using CAD/CAM is presented. The information of abutment teeth is transferred to a computer through a 3-dimensional scanner. A Konus inner and outer crown is designed on a computer and a real crown is machined based on this design using CAM. This method can save laboratory time and reduce inaccuracies compare to conventional casting procedure. A stone model with six prepared abutment teeth from a patient was used in this study. Three dimensional information from the model was transferred to a computer using a contact type 3-dimensional scanner with a $25{\mu}m$ accuracy. All margins were identified on a computer image where there is a change in surface taper of a model. To provide a cement space, the image of a inner sur face of a Konus inner crown was duplicated $25{\mu}m$ apart from the surface of a prepared abutment teeth image. The cement space was $20{\mu}m$ at the cervical margin. All Konus crowns were machined with a $10{\mu}m$ accuracy. It was concluded that this method can reduce working-time for the laboratory process and increase accuracy. A further research is required to make a simplified process for a more complex prosthesis.

  • PDF

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.