• 제목/요약/키워드: Absorption fluid

검색결과 243건 처리시간 0.029초

$H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$를 이용한 2중 효용 흡수식 냉동기 특성해석 (Characteristic Analysis of Double Effect Absorption Refrigeration Machine using $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$)

  • 문춘근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.792-799
    • /
    • 1998
  • Further improvement of existing $H_{2}O/LiBr$ absorption refrigeration machine is absolutely neces-sary to promote the utilization of gas-cooling system Among various methods to improve the per-formance of the absorption refrigeration machine this research has focused on the use of a new working fluid that has better properties than the existing $H_{2}O/LiBr$ working fluid. In the series of the research, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ system was selected as the most promisable candidate. The absorption refrigeration machine is water-cooled double-effect, $H_{2}O/LiBr+HO{(CH_{2})}_{3}OH$ sys-tem with series flow type. In this study we found out the characteristic of new working solution through the cycle simulation and compared the result with that of LiBr solution to evaluate. Theoptimum designs and operating conditions were determined based on the operating constraints and the coefficient of performance. Results demonstrate that new working fluid subsrantially increases COP by as much as 10% and has a wider working range with 8% higher crystallization limits compared to the conventional $H_{2}O/LiBr$.

  • PDF

태양열 구동 $NH_3/H_2O$ 흡수식 냉동기 리모델링 연구 (A Study on Remodeling for Solar driven $NH_3/H_2O$ absorption chiller)

  • 신유수;맹주성;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제23권4호
    • /
    • pp.37-43
    • /
    • 2003
  • The aim of this research is to study the feasibility of the solar(hot fluid) driven $NH_3/H_2O$ absorption chiller, made by re-manufacturing of Gas fired $NH_3/H_2O$ absorption chiller. This experimental study is performed with the temperature of the inlet hot fluid of generator. In order to determine the inlet temperature of the generator, which gives maximum COP, the experimental data are obtained with various hot fluid supply temperature in range of $130\sim170^{\circ}C$. Remodeled chiller is operated with periodical cooling effect, which due to mixture subcooled pool boiling, then the COP is evaluated in average. The maximum COP$(\sim0.36)$ is at $160^{\circ}C$. The temperature is stable operation temperature range of typical vacuum collector. It offers a feasibility of solar driven $NH_3/H_2O$ absorption chiller.

Efficient Representation of Pore Flow, Absorption, Emission and Diffusion using GPU-Accelerated Cloth-Liquid Interaction

  • Jong-Hyun Kim
    • 한국컴퓨터정보학회논문지
    • /
    • 제29권6호
    • /
    • pp.23-29
    • /
    • 2024
  • 본 논문에서는 옷감과 입자 기반 유체 해법인 SPH(Smoothed particle hydrodynamics)를 이용한 액체 간의 상호작용으로 표현되는 다공성 흐름(Pore flow), 흡수, 방출 그리고 확산 효과를 GPU 기반으로 빠르게 표현할 수 있는 방법을 제안한다: 1) 옷감-액체의 상호작용에 의해 표현되는 다양한 물리적 효과를 GPU 기반으로 표현할 수 있는 통합형 프레임워크, 2) SPH 기반으로 노드의 포화도를 효율적으로 계산하고 이를 주변 Porous 입자들로 전달하는 방법, 3) 유체 흡수 및 방출 방향을 안정적으로 계산하기 위해 다르시 법칙(Darcy's law)을 기반으로 안정성을 개선시키는 방법, 4) Porous 입자들로 흡수되는 과정에서 유체의 흐름 방향에 따라 흡수되는 양을 조절하는 방법, 마지막으로 5) SPH 입자의 최대 질량이 넘지 않도록 방출할 수 있는 방법을 제시한다. 제안하는 방식의 가장 큰 장점은 모든 연산이 GPU에서 계산되고 동작하기 때문에 빠르게 옷감과 유체의 상호작용으로 표현되는 다공성 재질, 다공성 흐름, 흡수, 반사, 확산 등을 모델링할 수 있다.

Glucose Prediction in the Interstitial Fluid Based on Infrared Absorption Spectroscopy Using Multi-component Analysis

  • Kim, Hye-Jeong;Noh, In-Sup;Yoon, Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.279-285
    • /
    • 2009
  • Prediction of glucose concentration in the interstitial fluid (ISF) based on mid-infrared absorption spectroscopy was examined at the glucose fundamental absorption band of 1000 - 1500/cm (10 - 6.67 um) using multi-component analysis. Simulated ISF samples were prepared by including four major ISF components. Sodium lactate had absorption spectra that interfere with those of glucose. The rest NaCl, KCl and $CaCl_2$ did not have any signatures. A preliminary experiment based on Design of Experiment, an optimization method, proved that sodium lactate influenced the prediction accuracy of glucose. For the main experiment, 54 samples were prepared whose glucose and sodium lactate concentration varied independently. A partial least squares regression (PLSR) analysis was used to build calibration models. The prediction accuracy was dependent on spectrum preprocessing methods, and Mean Centering produced the best results. Depending on calibration sample sets whose sodium lactate had different concentration levels, the standard error prediction (SEP) of glucose ranged $17.19{\sim}21.02\;mg/dl$.

낙하 충격 실험을 통한 자기유변탄성체의 충격 흡수 성능 평가 (The Evaluation of Shock Absorption Performance of Magneto-Rheological Elastomer Through the Drop Impact Test)

  • 정경식;이철희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.92-93
    • /
    • 2013
  • In this study, Shock Absorption performance of Magneto-rheological elastomer(MRE) is identified through the drop impact test. Magneto-rheological materials are divided into two groups by MR fluid in fluid state and MR elastomer in solid state like rubber. The stiffness characteristics of Magneto-rheological material can be changed as magnetic field is applied. The impact loads in MR elastomer were measured under weight of impactor. Experiment results are shown through the experiments to confirm the effect of shock absorption of MR elastomer. Thus, the MR elastomer can be applied to shock absorber used in area that shock occurs.

  • PDF

공냉식 흡수식 냉동기의 특성 해석 (Characteristic analysis of air-cooled absorption refrigeration machine)

  • 권오경;문춘근;양영명;유선일;윤정인
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1998년도 추계학술발표회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the study of developing air-cooled absorption system which uses a new working solution instead of LiBr solution to improve the performance of system. The absorption chiller-heater considered was an air-cooled, double-effect, $H_2O/LiBr+HO(CH_2)_3$ system of parallel flow type. In this study, we found out the characteristic of new working solution through the cycle simulation and compared the result that of LiBr solution to evaluate. The new working fluid has a wider working range with $8\%$ higher crystallization limit at the saturated refrigerant pressure of 0.8kPa. The optimum designs and operating conditions of air-cooled absorption system were suggested based on this cycle simulation analysis. It was demonstrated that new working fluid substantially improves the performance of the absorption refrigeration machine and is expected to increase the COP by as much as $5\%$.

  • PDF

메탄올-글리세린 계를 작동유체로 하는 변형흡수식 열펌프 설계 (Design of an Absorption Heat Transformer with Methanol-Glycerine System as a Working Fluid)

  • 정찬교;민병훈
    • 청정기술
    • /
    • 제11권1호
    • /
    • pp.13-19
    • /
    • 2005
  • 에너지 회수를 위한 변형 흡수 열펌프 연구를 메탄올-글리세린을 이용하여 수행하였다. 이 물질의 열역학 데이터를 이용하여 변형 흡수 열펌프의 이론적 열효율 값을 각 기관의 조업 조건에 따라서 계산하였다. $70-80^{\circ}C$의 산업 폐열 온도를 가지고 $40-50^{\circ}C$ 승온 시킬 때 열효율 값 0.4이상을 얻을 수 있었다.

  • PDF

Estimation of the Endogenous Pancreatic/Biliary Zinc Pool and the Effect of Phytate and Calcium on Zinc Homeostasis

  • Kwun, In-Sook;Donald Oberleas
    • Preventive Nutrition and Food Science
    • /
    • 제2권1호
    • /
    • pp.35-41
    • /
    • 1997
  • The pancreas is an important organ in the maintenance of zinc homeostasis. Endogenous zinc is con-tinuously secreted via pancreatic exocrine fluid or to a lesser extent in bile. Much of the endogenous secretion must be reabsorbed to sustain zinc homeostasis. The objective of this study was to estimate the relative size of the pancreatic/biliary zinc pool in comparision to the dietary zinc intake, and to study the effect of the phytate and calcium on the zinc homeostasis using a rat model. At the termination of the experiment, pan-creatic/biliary fluid was collected from the rats. Both radioactivity and total zinc were measured and the relative size of the pancreatic/biliary zinc pool was estimated. To determine the effect of phytate and calcium on zinc homeostsis, dietary zinc intake, the amount of zinc in pancreatic.biliary fluid and fecal zinc excretion were measured. The flow rate of pancreatic/biliary fluid, as corrected for tubing constriction, gives the corrected zinc concentration in the pancreatic/biliary fluid was 2.2 times higher than dietary zinc intake. To maintain zinc homeostasis, zinc absorption/reabsorption was very efficient in the current model; 76%, 88% of absorption/reabsorption for low calcium group and high calcium group 81% for phytate group and non-phytate group, respectively.

  • PDF

축대칭 부유구조물을 가지는 부유식 해양구조물의 3차원 지진응답 해석기법 개발 (Analysis of Three-dimensional Earthquake Responses of a Floating Offshores Structure with an Axisymmetric Floating Structure)

  • 이진호;김재관
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.145-159
    • /
    • 2015
  • A seismic response analysis method for three-dimensional floating offshore structures due to seaquakes is developed. The hydrodynamic pressure exerted on the structure is calculated taking into account the compressibility of the sea water, the fluid-structure interaction, the energy absorption by the seabed, and the energy radiation into infinity. To validate developed method, the hydrodynamic pressure induced by the vibration of a floating massless rigid circular disk is calculated and compared with an exact analytical solution. The developed method is applied to seismic analysis of a support structure for a floating offshore wind turbine subjected to the hydrodynamic pressures induced from a seaquake. Analysis results show that earthquake response of a floating offshore structure can be greatly influenced by the compressibility of fluid, the depth (natural frequencies) of the fluid domain, and the energy absorption capacity of the seabed.

나노입자 유체댐퍼를 이용한 보행 충격 완화 장치의 충격 흡수에 대한 실험적 연구 (Experimental Study of Shoe Cushioning System of Shock Absorption Using Fluid Damper with Nano Particles)

  • 문병영
    • 유공압시스템학회논문집
    • /
    • 제2권2호
    • /
    • pp.14-20
    • /
    • 2005
  • This study developed and evaluated a shoe cushioning system to reduce impact force patterns during running. The shoe cushioning system is composed with a poly urethane pocket, which contains water and porous grains to absorb the force against the weight inside the pocket. Load-displacement curves for the shoe cushioning system were obtained from an instrumented testing machine and the results were compared with various pockets that have air, water or grains. Mechanical testings showed that the pocket with 5 g particles was the best for the shoe cushioning system. This founding will be helpful to designing the shoe.

  • PDF