• Title/Summary/Keyword: Absorptance efficiency

Search Result 6, Processing Time 0.018 seconds

Design of an Antireflection Coating for High-efficiency Superconducting Nanowire Single-photon Detectors

  • Choi, Jiman;Choi, Gahyun;Lee, Sun Kyung;Park, Kibog;Song, Woon;Lee, Dong-Hoon;Chong, Yonuk
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.375-383
    • /
    • 2021
  • We present a simulation method to design antireflection coating (ARCs) for fiber-coupled superconducting nanowire single-photon detectors. Using a finite-element method, the absorptance of the nanowire is calculated for a defined unit-cell structure consisting of a fiber, ARC layer, nanowire absorber, distributed Bragg reflector (DBR) mirror, and air gap. We develop a method to evaluate the uncertainty in absorptance due to the uncontrollable parameter of air-gap distance. The validity of the simulation method is tested by comparison to an experimental realization for a case of single-layer ARC, which results in good agreement. We show finally a double-layer ARC design optimized for a system detection efficiency of higher than 95%, with a reduced uncertainty due to the air-gap distance.

Fabrications and Characteristics of Infrared Sensor Composed of λ/4 Absorbing Structure for the Application of NDIR CO2 Gas Sensor (λ/4 흡수층 구조를 갖는 NDIR 이산화탄소 가스센서용 적외선 센서의 제조 및 특성)

  • Lee, Sung-Hyun;Nam, Tae-Woon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1005-1009
    • /
    • 2008
  • A noble infrared $\lambda/4$ absorbing structure using metal reflector was studied for uncooled infrared sensors. This paper described the design and the fabrication of IR uncooled detectors which were composed of 21 by 21 elements using the surface micromachining technology. The characteristics of the array were investigated in the spectral region of 4.26 ${\mu}m$. The fabricated detectors exhibited the thermal mass of $9.75\times10^{-9}$ J/K, the thermal conductance of $1.31\times10^{-6}$ W/K, the thermal time constant of 7.4 ms, the responsivity of $1.07\times10^5$ V/W and the detectivity of $1.04\times10^9$ $cmHz^{1/2}/W$, at the chopper frequency of 10 Hz and the bias current of 9.22${\mu}A$. Finally the absorptance efficiency of $\lambda/4$ absorbing structure was about 23.2 % higher than that of absence absorbing structure.

The Study of The Collector Efficiency Curve (태양열 집열기 효율곡선에 대한 연구)

  • Shin, J.C.
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.198-202
    • /
    • 2014
  • In the solar heat collection system, we can determine how the collector will perform under specific conditions from the efficiency curve. By understanding the basic principles which govern the operation, designers can maximize the output from the collector. Absorptance, transmission and the total heat transfer coefficient were introduced to induce this efficiency curve. Designers who can make use of the implicit information on the curve in this report will generate systems which obtain the best return from their client's investment.

Development of Passive Solar Water Heater 1. Selective absorbers (자연형 온수 급탕시스템 개발)

  • Lee, K.D.;Auh, P.C.M.;You, C.K.
    • Solar Energy
    • /
    • v.4 no.2
    • /
    • pp.29-36
    • /
    • 1984
  • This paper reviews the current status of R&D work on selective absorber materials. For the efficient utilization of solar energy, various types of selective absorber materials are being used for solar hot water heaters. Many selective absorbers which have been proposed and designed up to data are classified according to the absorption mechanisms. Temperature-time cycle method is often recommended for the measurement of solar absorptance. In addition, conversion efficiency of the solar collector with selective surface is compared with one with black paint surface.

  • PDF

Study on the Resistance characteristics with the Bridge length of the Uncooled infrared sensor with high absorptance (고흡수율 비냉각형 적외선 센서의 브릿지 길이에 따른 저항특성 연구)

  • Kang, Hyeong-Gon;Lee, Hae-Seong;Lim, Yong-Geun;Park, Seung-Bum;Lee, Hong-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.464-467
    • /
    • 2004
  • An uncooled infrared sensor has been prepared with sputtering, plasma ash, ICP, and PECVD on a Si wafer In order to analyze the resistance characteristics with the bridge length in the infrared sensor, three samples were prepared with lengths of 0 (no bridge), 15 (short bridge), and 29 urn (long bridge), respectively. I-V curves were measured for their resistance characteristics and EPMA for the dopping concentration of the amorphous Si. The phosphorus concentration was about 4 % and the resistance was increased with the bridge length. The bridge length of cantilever is very important factor for improvement of the efficiency in an infrared sensor.

  • PDF

Application of Pulse Current Electrolysis to the Large Scale of Copper and Aluminium Substrates for Solar Selective Coatings on Solar Collectors (실 규모 태양열 집열판 제작을 위한 구리 및 알루미늄 기판에의 태양광 선택흡수박막 전착;Pulse Current Electrolysis 적용)

  • 이태규;김동형;김형택;여운택
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.108-114
    • /
    • 1996
  • It is one of the most important factors to enhance the efficiency of the solar collectors by in-creasing collecting efficiency and decreasing heat loss. The pulse electrodeposition method has been involved in this study to improve characteristics of the solar selective coating on 230cm${\times}$60cm substrates and electrical efficiency of the process. The composition of the electrolyte was 280 g/$\ell$ chromic acid, 15 g/$\ell$ propionic acid, and 10 g/$\ell$ appropriate additive. 230cm${\times}$60cm copper and aluminium sheets were utilized as the substrates. It has been observed that the black chrome coatings exhibited reasonable optical properties for commercialization when the plating parameters were properly controlled; the absorptance was 0.98 and 0.97 and omittance was 0.17 and 0.23 for copper and aluminium substrate, respectively. This study implies that the pulse current electrolysis method could be applied to the large scale substrates, and the various products can be avilable after the consideration of the thermal conductivity, heat transfer efficiency and cost problems of the substrates.

  • PDF