• Title/Summary/Keyword: Absorbed Doses

Search Result 206, Processing Time 0.025 seconds

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Assessment of Maternal Organs and Fetal Doses in Pregnant Female Nuclear Medicine Practitioners Using the Monte Carlo Method (몬테카를로 방법을 이용한 임신한 여성 핵의학 종사자의 모체 장기 및 태아선량 평가)

  • Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.331-339
    • /
    • 2022
  • The purpose of this study was to evaluate maternal organ and fetal doses by week of pregnancy for pregnant women nuclear medicine practitioners in the nuclear medicine field. In addition, we intend to present basic data for the management of exposure doses of female nuclear medicine practitioners. In this study, phantoms of childbearing women, 3, 6, 9 months pregnant women were simulated using MCNPX(Monte Carlo N-Particle Extended) among the Monte Carlo methods. First, volume source was constructed based on 10 cm of the anterior part of the lower abdomen of the phantom, and the organ and fetal doses were evaluated for each week of the pregnant woman according to the type of radioactive isotope. Second, the organ and fetal dose of pregnant women were evaluated by increasing the distance between the source and the abdominal surface by 50 and 100 cm. As a result, 18F sources showed high organ and fetal doses in pregnant women 0 to 3 months, and the dose distribution gradually decreased in 6 to 9 months pregnant women. The distribution of organ and fetal doses for 99mTc and 123I sources showed the same tendency as that of 18F, and the overall absorbed dose distribution was relatively lower than that of 18F. Through this study, it is considered that workers in the early stages of pregnancy within 3 months will need appropriate management to minimize occupational exposure dose.

Detection and Absorbed-Dose Estimation of Electron Beam-Irradiated Dried Vegetable Using ESR Spectroscopy (ESR Spectroscopy에 의한 전자선 조사 건조 채소의 검지와 흡수선량 예측)

  • 권중호;정형욱
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.4
    • /
    • pp.882-885
    • /
    • 1999
  • Along with the increasing demands for food irradiation technology, proper detection methods for controlling irradiated foods are required. Dried vegetable(chunggyungchae), which is permitted to be irradiated in Korea, was subjected to a detection study by ESR spectroscopy. Pre established threshold value was successfully applicable to the detection of 50 coded unknown samples of dried clean vege tables, both nonirradiated and electron beam irradiated. Three calibration curves obtained from the samples irradiated at 2.5~15 kGy were not practically adopted to estimate actual absorbed doses ranging from 4 to 7 kGy.

  • PDF

The Effect of Electron Beam Irradiation on Discoloration and Thermal Property of HDPE Filled with Antioxidants and UV Stabilizers (전자선 조사에 따른 산화방지제 및 자외선안정제 첨가 HDPE의 변색 영향과 열적 특성 분석)

  • Jeun, Joon Pyo;Jung, Seung Tae;Kim, Hyun Bin;Oh, Seung Hwan;Kang, Phil Hyun
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.23-28
    • /
    • 2013
  • In this study, we fabricated high density polyethylene (HDPE) composites filled with antioxidants and UV stabilizers. The electron beam irradiation on the fabricated composites was carried out over a range of absorbed doses from 50 to 200 kGy to confirm the changes of discoloration. The changes of discoloration were characterized using a color difference meter and FT-IR for confirming the changes of the color difference and structural change. It was observed that the color difference of IRGANOX 1010-, IRGAFOS 168-, and TINUVIN 328- added HDPE was higher than that of the control HDPE by electron beam irradiation. The melting temperature of UV stabilizer-added HDPE was not significantly changed by electron beam irradiation. However, the melting temperature of phenol-containing antioxidant-added HDPE was increased with increasing the absorbed dose. And the melting temperature of phosphorus-containing antioxidant-added composite was decreased with increasing the absorbed dose.

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.

A absorbed and effective dose from the full-mouth periapical radiography using portable dental x-ray machine and panoramic radiography (ORIGINAL ARTICLE - 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영과 파노라마방사선촬영의 흡수선량과 유효선량 평가)

  • Han, Won-Jeong
    • The Journal of the Korean dental association
    • /
    • v.50 no.7
    • /
    • pp.420-430
    • /
    • 2012
  • Purpose: The purpose of this study was to measure the absorbed dose and to calculate the effective dose for full-mouth periapical radiography using the portable dental x-ray machine and panoramic radiography Material and Method: Thermoluminescent chips were placed at 25sites throughout the layers of the head and neck of a tissue-equivalent human skull phantom. The man phantom was exposed with the portable dental x-ray machine and panoramic unit. During full-mouth periapical radiography the exposure setting was 60 kVp, 2 mA and 0.15 ~ 0.25 seconds, while during panoramic radiography the selected exposure setting was 72 kVp, 8 mA and 18 seconds. Absorbed dose measurements were obtained and equivalent doses to individual organs were summed using ICRP 103 to calculate of effective dose. Result: In the full-mouth periapical radiography, the highest absorbed dose was recorded at the mandible body follow with submandibular glands and cheek. Using panoramic unit, the highest absorbed dose was parotid glands and the following was back of neck and submandibular glands. The effective dose in full-mouth periapical radiography using portable dental x-ray machine was 46 ${\mu}Sv$. In panoramic radiography, the effective dose was 38 ${\mu}pSv$. Conclusion: It was recommended to panoramic radiography for general check in the head and neck area because that the effect dose in the panoramic radiography was lower than the dose in the full-mouth periapical radiography using portable dental x-ray machine.

Evaluation of effective dose in panorama, cone beam CT and the usefulness of x-ray protective (치과방사선검사에서 방사선방어용구 사용 전, 후의 유효선량에 대한 평가)

  • Kim, Jae In;Choi, Won Keun;Lee, So La;Lee, Jung Hwa;Lee, Kwan Sub
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.15-22
    • /
    • 2012
  • The purpose of this study was to measure the absorbed dose and calculate the effective dose for cone beam computed tomography (CBCT) and panorama units and to estimate usefulness of x-ray protective. Rando phantom and glass dosimeters were used for dosimetry. The absorbed doses were measured at 15 organs and 14 remainder from correspond to ICRP 2007 recommendations. The absorbed dose was highest in salivary glands as measured CBCT 2.420mGy, panorama 0.307mGy. Absorbed dose in another organs were high in order of thyroid, brain, skin, esophagus. The effective dose was CBCT 0.100mSv, panorama 0.011mSv and effective dose of panorama was higher than that of CBCT by 10 times. In case of wearing x-ray protective, reducing effective dose of CBCT by 0.066mSv (66%) and panorama by 0.008mSv (72%). Effective dose were reduced by radiological shielding but it needs further optimization studies, where dosimetric data are analyzed in combination with image quality with keep the patients' exposure as low as possible.

  • PDF

A Comparison of Density and Patient Doses According to kVp and mAs Changes in General Radiography (일반촬영에서 kVp와 mAs의 변화에 따른 농도와 환자 선량 비교)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.987-994
    • /
    • 2019
  • Low energy x-rays that occur in the low tube voltage radiography of general radiography are absorbed strongly in the body and do not aid image quality enhancement. This study maintains titer in general radiography while using tube current that are proportional to density and the tube voltage 15% principle according to density to reduce patient exposure doses, and area doses and entrance surface doses were measured to compare patient exposure doses. In hand, knee, abdomen, and skull radiography, kVp was increased to 115% and mAs was decreased to 50% and kVp was decreased to 85% while mAs was increased to 200% and area doses and entrance surface doses were measured to compare relative doses. Also, 5 places in each image were set, density was measured, and Kruskal wallis H test was conducted to observe significance probabilities between groups. To fix density, kVp was increased to 115% and mAs was decreased to 50% and after measurements of mean area doses and entrance surface doses were made by each part, each decreased to 58.68% and 59.85% when standard doses were set to 100%, and each increased to 147.28% and 159.9% when kVp was decreased to 85% and mAs was increased to 200%. Comparisons of density changes showed that hand, knee, abdomen, and skull radiography all displayed significance probabilities>0.05, showing no changes in concentration. Radiography that increases kVp and lowers mAs through reasonable calculations within ranges that don't affect resolution and contrast seems to be a simple way to decrease patient exposure doses.

ESR Signal in Different Cuts of Irradiated Chicken, Pork and Beef

  • Nam, Hye-Seon;Yang, Jae-Seung;Ly, Sun-Yung
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to detect irradiated meat containing bones (chicken, pork and beef), to investigate the effect of irradiation dose on the ESR signal intensity and to identify the stability of radicals under 9 weeks of storage. Chicken, pork and beef were irradiated with doses 0, 1, 3, 5 and 7 kGy at room temperature using a Co-60 irradiator. Bones were pieced and dried, which were placed in a quartz tube within an Electron paramagnetic resonance (EPR) spectrometer resonator cavity. The irradiated bone presented an asymmetric absorption in shape, different from that of a non-irradiated one. The signal intensity of smaller animals are lower than larger species. Variation was observed between samples of the same species depending on the calcification status of the bone. Moreover different irradiation doses produced different signal areas that make possible to estimate the absorbed dose of treated meat. The ESR signal stability after irradiation was stable in even after a 9 week storage at room temperature.

  • PDF

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.