• 제목/요약/키워드: Absorbable

검색결과 259건 처리시간 0.026초

안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고 (Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report)

  • 서용훈;김영준
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

Effects of a Non-absorbable Gas on the Absorption Process in a Vertical Tube Absorber

  • Hur, ki-Joon;Jeong, Eun-Soo;Jeong, Si-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.69-78
    • /
    • 1999
  • Effects of a non-absorbable gas on the absorption process in a vertical tube absorber has been investigated numerically. The water vapor mixed with air is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. The local absorption rate has been shown to decrease as the mass fraction of air in the water vapor increases. The vapor pressure of water at the liquid-vapor is interface reduced significantly since the non-absorbable gas accumulates near the interface. The effects of non-absorbable gases on absorption rate become larger as the mass flow rate of the vapor decreases. For a small amount of non-absorbable gases, the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. The total absorption rate increases as the mass flow rate of the vapor increases for large concentrations of non-absorbable gases at the inlet of an absorber.

  • PDF

Rumen Degradability and Small Intestinal Digestibility of the Amino Acids in Four Protein Supplements

  • Wang, Y.;Jin, L.;Wen, Q.N.;Kopparapu, N.K.;Liu, J.;Liu, X.L.;Zhang, Y.G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제29권2호
    • /
    • pp.241-249
    • /
    • 2016
  • The supplementation of livestock feed with animal protein is a present cause for public concern, and plant protein shortages have become increasingly prominent in China. This conflict may be resolved by fully utilizing currently available sources of plant protein. We estimated the rumen degradability and the small intestinal digestibility of the amino acids (AA) in rapeseed meal (RSM), soybean meal (SBM), sunflower seed meal (SFM) and sesame meal (SSM) using the mobile nylon bag method to determine the absorbable AA content of these protein supplements as a guide towards dietary formulations for the dairy industry. Overall, this study aimed to utilize protein supplements effectively to guide dietary formulations to increase milk yield and save plant protein resources. To this end, we studied four cows with a permanent rumen fistula and duodenal T-shape fistula in a $4{\times}4$ Latin square experimental design. The results showed that the total small intestine absorbable amino acids and small intestine absorbable essential amino acids were higher in the SBM (26.34% and 13.11% dry matter [DM], respectively) than in the SFM (13.97% and 6.89% DM, respectively). The small intestine absorbable Lys contents of the SFM, SSM, RSM and SBM were 0.86%, 0.88%, 1.43%, and 2.12% (DM basis), respectively, and the absorbable Met contents of these meals were 0.28%, 1.03%, 0.52%, and 0.47% (DM basis), respectively. Among the examined food sources, the milk protein score of the SBM (0.181) was highest followed by those of the RSM (0.136), SSM (0.108) and SFM (0.106). The absorbable amino acid contents of the protein supplements accurately reflected protein availability, which is an important indicator of the balance of feed formulation. Therefore, a database detailing the absorbable AA should be established.

Two-Year Follow-up on the Use of Absorbable Mesh Plates in the Treatment of Medial Orbital Wall Fractures

  • You, Jae-Pil;Kim, Deok-Woo;Jeon, Byung-Joon;Jeong, Seong-Ho;Han, Seung-Kyu;Dhong, Eun-Sang;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • 제40권6호
    • /
    • pp.728-734
    • /
    • 2013
  • Background Absorbable materials offer many advantages in the reconstruction of orbital walls; however, the possibility of postoperative enophthalmos after complete absorption cannot be excluded. We evaluated the postoperative results of absorbable mesh plates used as onlay implanting on the medial orbital wall to determine whether they are suitable for medial orbital wall reconstruction. Methods The study included 20 patients with medial orbital wall fractures who were followed up for more than 2 years postoperatively. We used absorbable mesh plates in all of the patients. We measured the following: the changes in the expanded orbital volume by comparing the preoperative and postoperative computed tomography (CT) scans and the degree of clinical enophthalmos. Results There were no major complications associated with the use of absorbable materials such as infection, migration, or extrusion of mesh plates during the long-term follow-up. The orbital volumetric changes between the preoperative and postoperative CT scans were not statistically significant. However, the expanded orbital volume was not related to the degree of clinical enophthalmos. Conclusions The reconstructed orbital wall may provide supportive scar tissue to the orbital contents even after the absorbable materials have dissolved completely. Absorbable mesh plates could be another option for the reconstruction of the medial orbital wall.

A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures

  • Alawode, Akeem O.;Adeyemi, Michael O.;James, Olutayo;Ogunlewe, Mobolanle O.;Butali, Azeez;Adeyemo, Wasiu L.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권4호
    • /
    • pp.159-166
    • /
    • 2018
  • Objectives: The aim of the study was to compare wound healing complications following the use of either absorbable or non-absorbable sutures for skin closure in cleft lip repair. Materials and Methods: This was a randomized controlled trial conducted at the Department of Oral and Maxillofacial Surgery, Lagos University Teaching Hospital, Idi Araba, Lagos State, Nigeria. Sixty subjects who required either primary or secondary cleft lip repair and satisfied all the inclusion criteria were recruited and randomized into two groups (Vicryl group or Nylon group). The surgical wounds in all subjects were examined on 3rd, 7th, and 14th postoperative days (POD) for presence or absence of tissue reactivity, wound dehiscence, and local wound infection. Results: Hemorrhage, tissue reactivity, wound dehiscence, and local wound infection were identified as wound healing complications following cleft lip repair. The incidence of postoperative wound healing complications on POD3 was 33.3%. Tissue reactivity was more common throughout the evaluation period with the use of an absorbable (Vicryl) suture compared to a non-absorbable (Nylon) suture, although the difference was statistically significant only on POD7 (P=0.002). There were no significant differences in the incidences of wound dehiscence and infection between the two groups throughout the observation period. Conclusion: There were no statistically significant differences in the incidences of wound dehiscence and surgical site wound infection following the use of either Vicryl or Nylon for skin closure during cleft lip repair. However, more cases of tissue reactivity were recorded in the Vicryl group than in the Nylon group on POD7. Particular attention must be paid to detect the occurrence of wound healing complications, most especially tissue reactivity, whenever a Vicryl suture is used for skin closure in cleft lip repair.

뚜껑문 안와저 골절에 있어서 망상 흡수성 판을 이용한 관혈적 정복술 및 내고정술 (Open Reduction and Internal Fixation (ORIF) of Trapdoor Orbital Floor Blowout Fracture with Absorbable Mesh Plate)

  • 권유진;김지훈;황재하;김광석;이삼용
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.619-625
    • /
    • 2010
  • Purpose: Trapdoor orbital blowout fracture is most common in orbital blowout fracture. Various materials have been used to reconstruct orbital floor blowout fracture. Absorbable alloplastic implants are needed because of disadvantages of nonabsorbable alloplastic materials and donor morbidity of autogenous tissue. The aim of the study is to evaluate usefulness of absorbable mesh plate as a reconstructive material for orbital blowout fractures. Methods: From December 2008 to October 2009, 18 trapdoor orbital floor blowout fracture patients were treated using elevator fixation, depressor fixation, or elevatordepressor fixation techniques with absorbable mesh plates and screw, depending on degree of orbital floor reduction, because absorbable mesh plates are less rigid than titanium plates and other artificial substitutes. Results: Among 18 patients, 5 elevator fixation, 4 depressor fixation, and 9 elevator and depressor fixation technique were performed. In all patients, postoperative computed tomographic (CT) scan showed complete reduction of orbital contents and orbital floor, and no displacement of bony fragment and mesh plate. Mean follow-up was 10 months. There were no significant intraoperative or postoperative complications. Conclusion: Three different techniques depending on the degree of orbital floor reduction are useful for open reduction and internal fixation of trapdoor orbital floor blowout fracture with absorbable mesh plates.

흡수성 망상판과 나사를 이용한 안면골절의 견고정법 (Rigid Fixation using Bioabsorbable Mesh and Screws in Facial Bone Fracture)

  • 신동혁;김덕중;김수영;황은아;최현곤;김순흠;엄기일
    • Archives of Plastic Surgery
    • /
    • 제37권5호
    • /
    • pp.717-720
    • /
    • 2010
  • Purpose: Absorbable plate and screw fixation is widely used technique for internal rigid fixation in craniomaxillofacial surgery. However, there are some potential problems associated with the use of plate. The purpose of this study is to evaluate the feasibility of bone fixation in facial fracture using absorbable mesh in place of absorbable plate. Methods: The records of 55 patients with zygomaticomaxilla fractures treated by open reduction, performed by the author from February 2008 to May 2009, were retrospectively reviewed. Patients were selected to receive absorbable mesh fixation. The incidence of all complications including infection, hypoesthesia, and deformity was examined. Analysis with postoperative computed tomography follow-up demonstrates degree of reduction. Results: Forty-six patients met criteria for inclusion in the study. All patients went on to satisfactory healing without complication. Postoperative computed tomography revealed good bony alignment similarly non affected side. Conclusion: This study demonstrates that the rigid internal fixation of fractured bone fragments using absorbable mesh is more effective than absorbable plate, especially in comminuted fracture of maxilla.

Granuloma Formation, a Rare Complication after PDO Threads Lifting, and Adjuvant Treatment Using Dual-Frequency Ultrasound (LDM®-MED)

  • Hong, Seok Won;Park, Eun Soo
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.35-38
    • /
    • 2019
  • Thread-lifting is a minimally invasive procedure that shows good results and fewer complications as compared with those results and complications of standard surgery. Many procedures and techniques have been developed to create a younger appearance of facial/neck skin for aging people, and the demand for an improved aesthetic appearance is increasing. Since the incidence of side effects is much less than that of non-absorbable threads, which can lead to complications such as foreign body reactions, polydioxanone (PDO) threads are predominantly used for face lift procedures. A 66-year-old woman presented to our clinic with inflamed palpable masses. She had undergone a face lift with absorbable threads in our clinic 5 months previously. Excisional biopsy was performed with the patient under local anesthesia. During the operation, any threads were not detected and there was both fibrotic scar tissue and granulomatous tissue. For effectively promoting healing and managing the scars, treatment with LDM®-MED was performed on the day after surgery. The treatment was performed according to the author's protocol. Although foreign body granuloma as a complication after using non-absorbable thread types have been previously reported, it is relatively rare to find this type of complication after using absorbable thread. In this report, we present a case in which a 66-year-old female with foreign body granuloma after undergoing a face lift using absorbable threads was treated with the application of dual-frequency ultrasound, which promoted wound healing.

Electrospun poly(D,L-lactic acid)/gelatin membrane using green solvent for absorbable periodontal tissue regeneration

  • Dayeon Jeong;Juwoong Jang;Deuk Yong Lee
    • 한국결정성장학회지
    • /
    • 제33권3호
    • /
    • pp.104-109
    • /
    • 2023
  • Electrospinning was performed using an eco-friendly solvent composed of acetic acid, ethyl acetate and distilled water to investigate the effect of gelatin concentration on mechanical properties and cytotoxicity of absorbable poly(D,L-lactic acid) (PDLLA)/gelatin blend membrane. The tensile stress, strain at break, and WUC of the PDLLA/gelatin (97/3) scaffold at 26 wt% concentration were determined to be 3.9 ± 0.7 MPa, 37 ± 1.3 %, and 273 ± 33 %, respectively. FT-IR results revealed that PDLLA and gelatin were bound only by van der Waals interactions. The cell viability of PDLLA/gelatin membranes containing 0 %, 1 %, 2 %, 3 %, and 4 % gelatin were more than 100 %, which makes all membranes highly suitable as a barrier membrane for absorbable periodontal tissue regeneration due to their marketed physical properties and biocompatibility.

Absorbable Plate as a Perpendicular Strut for Acute Saddle Nose Deformities

  • Kim, Jong-Gyu;Rhee, Seung-Chul;Cho, Pil-Dong;Kim, Deok-Jung;Lee, Soo-Hyang
    • Archives of Plastic Surgery
    • /
    • 제39권2호
    • /
    • pp.113-117
    • /
    • 2012
  • Background : Nasal pyramid fractures accompanied by saddle nose deformities are not easily corrected by closed reduction. We used an absorbable plate as a perpendicular strut to support the collapsed "keystone area" and obtained good results. Methods : Between September 2008 and June 2011, 18 patients who had nasal pyramid fractures with saddle nose deformities underwent surgery. Pre- and postoperative facial computed tomographic images and photographs were taken to estimate outcomes. The operative technique included the mucoperichondrial dissection of the nasal septum, insertion of an absorbable plate prepared to an appropriate length to support the "keystone area", and fixation of the absorbable plate strut to the cartilaginous septum. Results : Functional and esthetic outcomes were satisfactory in all patients. Eleven patients assessed the postoperative appearance of the external nose as 'markedly improved' and 7 patients as 'improved'. The 5 surgeons scored the results as a mean of 4.5 on a 5-point scale. Conclusions : The use of an absorbable plate as a perpendicular strut requires no additional procedures because the plate is gradually absorbed. The mechanical strength provided by a buttress between the "keystone area" and the maxillary crest lasts for a long time before the strut is absorbed.