• Title/Summary/Keyword: Absolute testing

Search Result 137, Processing Time 0.029 seconds

TRACKING FOR HIGH-ORDER DAMPING OF THIN BEAM OSCILLATION

  • Yoo, Wan-Suk;Lee, Jae-Wook;Kim, Hyun-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.984-989
    • /
    • 2008
  • An estimation of high-order damping in flexible multibody dynamic simulation is introduced in this paper. The suggested damping model based on the experimental modal analysis leads to more accurate correlation results comparing to the traditional linear damping model because it directly uses the modal parameters of each mode achieved from experiment even high frequency modes. The modal parameters until the 5th mode are extracted from the experimental modal testing of the flexible beam using a high speed camera. And using the measured damping ratio and natural frequency until the 5th mode, the generic damping model is constructed. Then, the ANCF (absolute Nodal Coordinate Formulation) simulation results are compared to experimental results until the 5th mode.

  • PDF

Diagnosis of Cast Resin Transformer Using Analysis of Surface Temperature Distribution (표면온도분포 분석을 이용한 몰드 변압기 진단)

  • Lim, Yong-Bae;Chun, Jong-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.444-447
    • /
    • 2003
  • All objects with some temperature above absolute zero radiate in the infrared. The intensity of the infrared radiated from a object defends on the condition and temperature on the surface of the one. The present, these techniques are frequently adopted into diagnosis for electricity equipments. Simply, however, the applied techniques are passive thermal testing for the detection of loosened terminals and overcurrent. In this paper, a infrared thermal imager was applied to high voltage windings of cast resin transformers, and the accumulated value of the result temperatures was used for evaluating remained lifetime of them. At each aging level, dielectric loss tangent test was carried out. The results offered capabilities for deciding the condition of the transformers suffering difficulties to diagnose.

  • PDF

Severity Test of Road Surface Profile by Using the Fatigue Life Prediction Method (피로수명 예측법을 이용한 각 도로가 차량의 내구성에 미치는 가혹도 평가)

  • Jung, W.W.;Kang, S.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.154-161
    • /
    • 1995
  • There are several kinds of driving conditions according to the characteristic of each vehicle diver. Automaker produces vehicle strong enough to satisfy this several driving conditions at the point of vehicle durability. In order to develop the car in a short period, Automaker engineer tests vehicle at serveral accelerated durability test roads. Before testing the vehicle durability, test engineer must know how much this test road severe than general field road which is composed of high way, city road, paved road and unpaved road. This paper suggests two types of road severity test method that is using relative fatigue life prediction method and using absolute fatigue life prediction method, and also present the merits and demerits of two test methods.

  • PDF

Video quality assessment of digital TV for direct broadcasting satellite (직접 위성 방송을 위한 디지틀 TV의 화질 평가)

  • 박대철;김경태;전현호;채종석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1370-1378
    • /
    • 1996
  • A subjective video quality assessment methods are proposed based on CCIR Rec. 500-5 for an evaluation and testing of compressed video quality and performance of video codec to be designed in accordance with the MPEG-2 MP ML specification which is adapted as a DTV standard for Korea digital DBS. Video sequence compressed in compliance with MPEG-2 MP ML encoding parameterswastested by the proposed video quality evaluation procedure. Test sequence were compressed at the bit rate 6Mbps, 7.5Mbps and 9Mbps, repectively. Test results of the 7.5Mbps bitrate showed a satisfactory picture quality at about 4.0 on the 5.0 absolute scale of ITU-R 500-5.

  • PDF

A two-phase model for usability evaluation of software user interfaces

  • Lim, Chee-Hwan;Park, Kyung-S.
    • Proceedings of the ESK Conference
    • /
    • 1997.10a
    • /
    • pp.313-319
    • /
    • 1997
  • There is currently a focus on usability of interactive computer software. Previous research in software ergonomics has indicated the importance of evaluating the usability of software user interfaces. Software developers, interface designers or human foctors engineers often confront the task of comparative evaluation among systems, versions or interface designs. This study presents a structured model for comparative evaluation of user interface designs using usability criteria and measures. The proposed model consists of twomain phases : the prescreening phase ad the evaluation phase. The first phase involves expert judgment-based approach with qualitative criteria. The prescreening phase uses absolute measurement analytic hierarchy process to filter possible altermative interfaces to a reasonable subset. The second phase involves user-based approach such as usability testing, with quantitative criteria. The objective of the evaluation phase is to evaluate a subset of altermatives using objective measures. A set of criteria and measures for evaluating the usability of computer software designs is presented. The proposed model provides practitioners with a structured approach to select the best interface based on usability criteria and measures.

  • PDF

Model based Stress Decision Method (모델 기반의 강세 판정 방법)

  • Kim, Woo-Il;Koh, Hoon;Ko, Han-Seok
    • Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.49-57
    • /
    • 2000
  • This paper proposes an effective decision method focused on evaluating the 'stress position'. Conventional methods usually extract the acoustic parameters and compare them to references in absolute scale, adversely producing unstable results as testing conditions change. To cope with environmental dependency, the proposed method is designed to be model-based and determines the stressed interval by making relative comparison over candidates. The stressed/unstressed models are then induced from normal phone models by adaptive training. The experimental results indicate that the proposed method is promising, and that it is useful for automatic detection of stress positions. The results also show that generating the stressed/unstressed model by adaptive training is effective.

  • PDF

Diagnostic Technique for Mold Transformer Windings using Thermal Image (열화상을 이용한 몰드변압기 권선표면 진단)

  • Lim, Y.B.;Jung, J.W.;Jung, J.S.;Ko, W.S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.107-109
    • /
    • 2005
  • Temperature distribution measured to estimate condition of an electrical apparatus is an absolute reference for the apparatus conditions and the difference between the reference temperature and the current one. Because a passive thermography without the external thermal stimulation shows the difference in surface temperature between the object and back ground, the results can apply only to the estimation or the monitoring for the condition of terminal loose and the overload pertaining to the rise in temperature. However, a thermal flow in the active thermography is differently generated by the structure and condition of the surface and subsurface. This paper presents the nondestructive testing using the behavior and deals with the results by heat injection and cooling to the apparatus. The buried discontinuity of subsurface could be detected by these techniques.

  • PDF

A Predictive Model for the Number of Potholes Using Basic Harmony Search Algorithm (하모니 검색 알고리즘을 이용한 포트홀 발생 개수 예측 모형)

  • Kim, Dowan;Lee, Sangyum;Kim, Dongho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.4
    • /
    • pp.150-158
    • /
    • 2014
  • A bunch of asphalt roads have been damaged frequently in relation to the rapid climate change. To solve and prevent this type of problems, many nationalities in the world have performed various researches. In this regard, the objective of this study is to develop prediction model as to the number of potholes occurred in seoul. At the same time, we have utilized empirical and statistical approaches in order for us to identify factors which is affecting the actual occurrence. The predictive model was determinded by using BHS (Basic Harmony Search) algorithm. Prediction was based on the weather and traffic data as well as data occurrence data of porthole. To assess the influences which are PAR(Pitch Adjusting Rate) and HMCR(Harmony Memory Considering Rate), we determined suitability by changing the values. In the process of the determining a predictive model, the predictive model composed Training data (2011, 2012 and 2013yrs data). To determine the suitability of the model, we have utilized Testing Set (2009 and 2010 yrs data). The suitability of the basic prediction model has been from RMSE(Root Mean Squared Error), MAE(Mean Absolute Error) and Coefficient of determination.

GafChromic Film Dosimetry for Stereotactic Radiosurgery with a Linear Accelerator (선형가속기를 이용한 정위방사선 치료 시 GafChromic Film을 이용한 선량측정)

  • Han Seung Hee;Cho Byung Chul;Park Suk Won;Oh Do Hoon;Park Hee Chul;Bae Hoon Sik
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.167-173
    • /
    • 2003
  • Purpose: The purpose of this study was to evaluate whether a GafChromic film applied to stereotactic radiosurgery with a linear accelerator could provide information on the value for acceptance testing and quality control on the absolute dose and relative dose measurements and/or calculation of treatment planning system. Materials and methods: A spherical acrylic phantom, simulating a patient's head, was constructed from three points. The absolute and relative dose distributions could be measured by inserting a GafChromic film into the phantom. We tested the use of a calibrated GafChromic film (MD-55-2, Nuclear Associate, USA) for measuring the optical density. These measurements were achieved by irradiating the films with a dose of 0-112 Gy employing 6 MV photon. To verify the accuracy of the prescribed dose delivery to a target isocenter using a five arc beams (irradiated in 3 Gy per one beam) setup, calculated by the Linapel planning system the absolute dose and relative dose distribution using a GafChromic film were measured. All the irradiated films were digitized with a Lumiscan 75 laser digitizer and processed with the RIT113 film dosimetry system. Results: We verified the linearity of the Optical Density of a MD-55-2 GafChromic film, and measured the depth dose profile of the beam. The absolute dose delivered to the target was close to the prescribed dose of Linapel within an accuracy for the GafChromic film dosimetry (of $\pm$3$\%$), with a measurement uncertainty of $\pm$1 mm for the 50$\~$90$\%$ isodose lines. Conclusion: Our results have shown that the absolute dose and relative dose distribution curves obtained from a GafChromic film can provide information on the value for acceptance. To conclude the GafChromic flim is a convenient and useful dosimetry tool for linac based radiosurgery.

Real-Time Hybrid Shaking Table Test of a Soil-Structure Interaction System with Dynamic Soil Stiffness (동적 지반강성을 갖는 지반-구조물계의 실시간 하이브리드 진동대 실험)

  • Lee, Sung-Kyung;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.217-225
    • /
    • 2007
  • This paper proposes the real-time hybrid shaking table testing methods to simulate the dynamic behavior of a soil-structure interaction system with dynamic soil stiffness by using only a structure model as the physical specimen and verifies their effectiveness for experimental implementation. Experimental methodologies proposed in this paper adopt such a way that absolute accelerations measured from the superstructure and shaking table are feedback to the shaking table controller, and then the shaking table is driven by the calculated motion of the absolute acceleration (acceleration feedback method) or the absolute velocity (velocity feedback method) of foundation that is required to simulate the dynamic behavior of a whole soil-structure interaction system. The shaking table test is implemented by reflecting the dynamic soil stiffness, which are differently approximated from the theoretical one depending on the feedback methods, on the shaking table controller to calculate soil part. The effectiveness of the proposed experimental methods is verified by comparing the response measured from the test on a foundation-fixed structural model and that obtained from the experiment of a soil-interaction system under the consideration in this paper and by matching the dynamic soil stiffness reflected on the shaking table controller with that identified using the experimentally measured data.