• 제목/요약/키워드: Absolute test

검색결과 661건 처리시간 0.03초

Absolute Temperature Measurement using White Light Interferometry

  • Kim, Jeong-Gon
    • Journal of the Optical Society of Korea
    • /
    • 제4권2호
    • /
    • pp.89-93
    • /
    • 2000
  • Recently a new signal processing algorithm for white light interferometry was presented. In this paper, the proposed signal processing algorithm was applied for absolute temperature measurement using white light interferometry. Stability testing and absolute temperature measurement were demonstrated. Stability test demonstrated the feasibility of absolute temperature measurement with an accuracy of 0.015 fringe. The test also showed that the absolute temperature measurement system using white light interferometry is capable of obtaining the theoretical minimum detectable change (0.0005 fringe), which is consistent with the performance predicted by the proposed signal processing algorithm.

석탄층 메탄가스 저류층의 유정생산시험 설계 및 수행절차 수립연구 (Development of Designing and Performing Procedure for Well Test in Coalbed Methane(CBM) Reservoir)

  • 박진영;이정환
    • 자원환경지질
    • /
    • 제46권4호
    • /
    • pp.279-289
    • /
    • 2013
  • 석탄층 메탄가스(coalbed methane; CBM)를 개발하는데 있어서 생산성과 경제성을 좌우하는 절대투과도(absolute permeability)를 산출하는 것은 매우 중요하다. 절대투과도를 측정하는 방법에는 코어분석(core analysis)과 유정생산 시험(well test) 등이 있다. 하지만 코어분석을 통해 도출된 절대투과도는 CBM 저류층을 대표할 수 없기에 일반적으로 유정생산시험을 통해 절대투과도가 산출된다. 이에 본 연구에서는 CBM 저류층에 적용 가능한 유정생산시험을 분류하고 각 시험기법별 특성 및 장 단점을 분석하였다. 이를 기반으로 유정생산시험 설계 및 수행절차를 수립하였으며, 유정생산시험 수행 후 취득된 자료를 통해 절대투과도와 손상지수(skin factor)와 같은 저류층 물성을 도출하기 위한 자료해석 절차를 제시하였다.

Weighted Least Absolute Error Estimation of Regression Parameters

  • Song, Moon-Sup
    • Journal of the Korean Statistical Society
    • /
    • 제8권1호
    • /
    • pp.23-36
    • /
    • 1979
  • In the multiple linear regression model a class of weighted least absolute error estimaters, which minimize the sum of weighted absolute residuals, is proposed. It is shown that the weighted least absolute error estimators with Wilcoxon scores are equivalent to the Koul's Wilcoxon type estimator. Therefore, the asymptotic efficiency of the proposed estimator with Wilcoxon scores relative to the least squares estimator is the same as the Pitman efficiency of the Wilcoxon test relative to the Student's t-test. To find the estimates the iterative weighted least squares method suggested by Schlossmacher is applicable.

  • PDF

한국 주식시장 상위 8개사에 대한 적합도 검정 및 독립성 검정 (Goodness of Fit and Independence Tests for Major 8 Companies of Korean Stock Market)

  • 민승식
    • 응용통계연구
    • /
    • 제28권6호
    • /
    • pp.1245-1255
    • /
    • 2015
  • 본 논문에서는 한국 유가증권시장의 시가총액 상위 8개사 주가 수익률 절대값(absolute return)을 이용하여, 분포의 적합도 검정(goodness of fit test) 및 기업들 간의 독립성 검정(independence test)을 실시하였다. 검정 결과 개별 주가 수익률은 압축된 지수분포(compressed exponential distribution)를 이루는 것으로 나타났다. 이 때 파라미터는 1 < ${\beta}$ < 2 인 경우가 ${\beta}=1$(지수분포), ${\beta}=2$(정규분포)보다 우세한 것으로 확인되었다. 한편 독립성 검정에서는 대부분의 기업들이 관련성을 지니고 있는 것으로 나타났다.

전류변성기 두 대와 절대 평가 기술을 이용한 2차 전류 범위 확장 (Secondary Current Range Extension of Current Transformers by Using Two Different Current Transformers and Absolute Evaluation Technique)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.72-78
    • /
    • 2009
  • We have developed a current range extension method to obtain the ratio error and phase displacement of a current transformer (CT) by using absolute evaluation method and two different CTs. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 1 A - 20,000 A / 1 A. The ratio error and phase displacement of the CT under test obtained in this study are consistent with those measured at the national institute in Germany using the same CT under test within an expanded uncertainty (k = 2) in the overall current ratios.

만성 뇌졸중 환자들의 Step Test의 상대적·절대적 신뢰도와 타당도 (The Relative·Absolute Reliability and Validity of Step Test in Patients with Chronic Stroke)

  • 이병권;최현수;안승헌
    • 대한통합의학회지
    • /
    • 제5권1호
    • /
    • pp.43-53
    • /
    • 2017
  • Purpose : To examine the relative absolute reliability and validity of step test (ST) scores in subjects with chronic stroke. Method : A total of 27 stroke patients, participated in the study. A relative reliability index (intraclass correlation coefficient, ICC) was used to examine the level of agreement of inter-rater test-retest reliability for ST score. Absolute reliability indices, including the standard error of measurement(SEM) and the minimal detectable change (MDC), and limits of agreement by Bland and Altman analysis. The validity was demonstrated by spearman correlation of ST score with 10 m Walk Test (10mWT), Fugl-Meyer Assessment-Lower/Extremity (FMA-L/E)-total score, Berg Balance Scale (BBS)-total score. Result : An excellent inter-rater reliability in ST scores was found (paretic, ICC=0.993~0.996; nonparetic, ICC=0.982~0.991). In addition, excellent test-retest reliability was found (paretic, ICC=0.992; nonparetic, ICC=0.967). It all showed acceptable SEM of the ST score as paretic and nonparetic were 0.22 and 0.46 respectively (average score <10 %), and the MDC of the paretic and nonparetic were 0.61 and 1.27 respectively (possible highest score <20 %). indicating that measures had a small and acceptable measurement error. The ST score of paretic and nonparetic were also found to be significantly associated with 10MWT (r=0.77~0.79), FMA-LE scores (r=0.73~0.81) and BBS scores (r=0.72~0.76). Conclusion : The ST showed highly sufficient Inter-rater test-retest agreement and validity and acceptable measurement errors caused by due to chance variation in measurement. It also can be used by clinicians and researchers to assess the balance and mobility performance and monitor functional change in chronic stroke patients.

정면충돌 시험결과와 딥러닝 모델을 이용한 흉부변형량의 예측 (Prediction of Chest Deflection Using Frontal Impact Test Results and Deep Learning Model)

  • 이권희;임재문
    • 자동차안전학회지
    • /
    • 제15권1호
    • /
    • pp.55-62
    • /
    • 2023
  • In this study, a chest deflection is predicted by introducing a deep learning technique with the results of the frontal impact of the USNCAP conducted for 110 car models from MY2018 to MY2020. The 120 data are divided into training data and test data, and the training data is divided into training data and validation data to determine the hyperparameters. In this process, the deceleration data of each vehicle is averaged in units of 10 ms from crash pulses measured up to 100 ms. The performance of the deep learning model is measured by the indices of the mean squared error and the mean absolute error on the test data. A DNN (Deep Neural Network) model can give different predictions for the same hyperparameter values at every run. Considering this, the mean and standard deviation of the MSE (Mean Squared Error) and the MAE (Mean Absolute Error) are calculated. In addition, the deep learning model performance according to the inclusion of CVW (Curb Vehicle Weight) is also reviewed.

절대유량법(ASFM)을 이용한 저낙차.카플란 수차효율측정 적용사례 연구 (Case study of a low head & kaplan turbine efficiency measurement using ASFM)

  • 이용준;오석영;신창식;현정재
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.205.1-205.1
    • /
    • 2011
  • This study concerns a low head and kaplan turbine efficiency measurement using the acoustic scintillation flow meter(ASFM). The ASFM is one of absolute discharge measurement methods because it measures velocity-area of discharge with couples of transducers. This study shows that the highest efficiency of turbine is 87.7% and the efficiency is 85.8% in the rated output(600kW). The test result is reliable because the efficiency trend from this test is similar to the result of index test conducted in 1986. In this paper, the principle, measurement methods, application and test procedures of the test are discussed.

  • PDF

Absolute Radiometric Calibration을 위한 Field Campaign과 시험결과 (Field Campaigns and test results for Absolute Radiometric Calibration)

  • 이선구;김용승
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.213-219
    • /
    • 2006
  • 한국항공우주연구원에서는 2006년 발사될 다목적실용위성 2호의 절대복사보정(absolute radiometric calibration)을 위한 준비로, Orbview-3 위성의 통과시간에 맞추어 2004년 11월 4일 과 2005년 3월 7일에 고흥과 대전에서 Field campaign을 수행하였다. 절대복사보정은 vicarious calibration 방법 중 targets의 반사 특성을 이용하는 방법으로, Field campaign을통해 수집된 지표자료와 대기자료들을 이용하여 top-of-radiance(TOA)를 추출하였다 대기 복사모델로는 MODTRAN 4.0이 사용되었으며, 추출된 TOA radiance와 Orbview-3 Panchromatic DN과 비교를 하여 절대복사보정을 위한 offset과 gain계수를 계산하였다. 또한 본 연구에서는 Field Campaign으로부터 축적된 경험을 이용하여 다목적실용위성 2호의 절대복사보정에 적용할 방법을 제안하였다.

  • PDF

국소적 부하와 전신적 부하가 슬관절 위치 감각에 미치는 영향 (The effects of knee joint position sense following local and general load protocols)

  • 황윤태;박래준;최진호
    • The Journal of Korean Physical Therapy
    • /
    • 제17권3호
    • /
    • pp.429-440
    • /
    • 2005
  • The purpose of this study was to compare the effects of knee joint position sense following local and general load protocols in 25 healthy male subjects. Proprioception of the knee joint was evaluated by measuring absolute angular errors at matching angles before, after and between 2 different types of load protocols. Proprioception tests(on the dominant knee) were performed in which proprioception of the passivepassive reproduced and active-active reproduced knee position was measured. Local load was provided with maximum isokinetic knee extension-flexion on the isokinetic dynamometer(Cybex), and general load was 10 minutes running on a treadmill. Peak torque(knee extension and flexion) and heart rate(beats per minute) was evaluated as an indicator of local and general fatigue during load protocols. The results were as follows: 1. For pasive-pasive reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol(P<.05). However, no significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol (P>.05), no significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P>.05). 2. For active-active reproduced knee position test, significant difference in absolute angular errors after general load protocol was detected compared with that before general load protocol(P<.05), significant difference in absolute angular errors after local load protocol was detected compared with that before local load protocol (P<.05). Also, significant difference in absolute angular errors of general load protocol was detected compared with that of local load protocol(P<.05), significant difference in absolute angular errors of local load protocol was detected compared with that of general load protocol(P<.05). 3. A significant decrease of peak torque of knee extensors and flexors was seen after local load, although heart rate was significantly increased(P<.05). No significant change of peak torque of knee extensors and flexors was seen after general load(P>.05), although heart rate was also significantly increased(P<.05). The previous study revealed that knee proprioception is significantly altered when the muscle mechanoreceptors are dysfunctional due to muscle fatigue, although the joint mechanoreceptors have no significantly effect on knee proprioception when the presence of knee muscle fatigue. However, the results of this study are different from those of the previous study in that muscle weakness of the knee could not be seen after general load. This study shows that general load may diminish motor control by the central nervous system. Proprioceptional decline without muscle weakness of knee after general load suggests a change in the proprioceptional pathway without influence from muscle mechanoreceptors.

  • PDF