Case study of a low head & kaplan turbine efficiency measurement using ASFM

절대유량법(ASFM)을 이용한 저낙차.카플란 수차효율측정 적용사례 연구

  • Published : 2011.05.26

Abstract

This study concerns a low head and kaplan turbine efficiency measurement using the acoustic scintillation flow meter(ASFM). The ASFM is one of absolute discharge measurement methods because it measures velocity-area of discharge with couples of transducers. This study shows that the highest efficiency of turbine is 87.7% and the efficiency is 85.8% in the rated output(600kW). The test result is reliable because the efficiency trend from this test is similar to the result of index test conducted in 1986. In this paper, the principle, measurement methods, application and test procedures of the test are discussed.

Keywords