• Title/Summary/Keyword: Absolute humidity

Search Result 80, Processing Time 0.024 seconds

Mechanecal Prolperties of Concerte as the Condition of Contained Water (함수상태에 따른 콘크리트의 역학적성상)

  • 김인수;오창희
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.1
    • /
    • pp.127-134
    • /
    • 1992
  • Generally speaking, the internal moisture of concrete is mainly distributed in inner part and concrete surface which is exposed are dned according to influence of temperature and humidity. So, the properties which are compressive strength, modular elasticity, and volume change are different at each part even in same concrete. This is because moisture distribution is changed according to the evaporation and move ment of moisture, exist in the inner porosity of concrete. Therefore, it is necessary that we investigate the properties of concrete according to moisture distribution. The purpose of this study is investigating correlation between the moisture content and mechanical properties in concrete. Compressive and tenslle strength decrease according to increasing moisture content, but modular elas ticity increase. Those increasing or decreasing ratio at drying ratio 100% (absolute dries) is as follows in comparative of drying ratio 0 % (saturated condition).tion).

An Experimental Study on Measure to Moisture Contents of Concrete (콘크리트 내부의 수분함유량 측정에 관한 실험적연구)

  • Park, Won-Sup;Kim, Heung-Youl;Kim, Hyung-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.428-433
    • /
    • 2008
  • The strength capacity properties of concrete are much influenced by water content which has a significant effect on concrete spalling, especially, in high temperature areas. Therefore, the properties of the material's shall be closely examined first by measuring the water content in each material in order to analyze Concrete Fire Characteristics, and a reliable measuring method shall be presented in order to derive the following influence. The method used to measure the water content within concrete is mainly divided into 4 types; ASTM method, Nuclear Magnetic method, Ultrasonic measurement method, Radio Wave method, etc. It is essential to use a reliable measuring method for each experiment. In this experiment, we measured the water content and humidity of concrete by two methods; Relative/Absolute humidity method using VISALA HM44 measuring equipment which is easily measurable compared with other methods regardless of the shape of the experimental model, and a water content measuring experiment using ASTM C 566. If the aggregates are under the condition that their surface is dry but in saturation, there is no change of water content according to concrete curing methods. However if the aggregates are absolutely dry, the water content is significantly changed according to concrete curing methods.

  • PDF

Development of Continuous Cross-Flow Rice Drying Model (벼의 횡류 연속식 건조 모델 개발)

  • 송대빈;고학균
    • Journal of Biosystems Engineering
    • /
    • v.22 no.3
    • /
    • pp.279-288
    • /
    • 1997
  • This study was worked out to obtain fundamental data needed for developing a continuous type dryer. The drying process in a cross-flow type continuous dryer was expressed as partial differential equations, and a drying simulation model for predicting rice moisture content, rice temperature, drying air absolute humidity, drying air temperature was developed by using the finite difference method. To validate the performance of the drying simulation model, a prototype continuous dryer was constructed in this study. The size of the test dryer was one-tenth to that of a commercial continuous dryer. The difference in the outlet rice moisture content between the predicted values and the measured values was within 0.5%, that of outlet rice temperature was below $3^{\circ}C$, that of drying air temperature in drying bed was within $8^{\circ}C$ and that of relative humidity of outlet drying air was big because of the different measuring point. In addition, a drying simulation model for a actual size continuous dryer with double flow was developed in this study. This drying simulation model included the rice mixing effect in the middle of drying length. The difference of outlet moisture content between the predicted and the measured values showed below 0.5% in this study.

  • PDF

Comparison Analysis of Machine Learning for Concrete Crack Depths Prediction Using Thermal Image and Environmental Parameters (열화상 이미지와 환경변수를 이용한 콘크리트 균열 깊이 예측 머신 러닝 분석)

  • Kim, Jihyung;Jang, Arum;Park, Min Jae;Ju, Young K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.2
    • /
    • pp.99-110
    • /
    • 2021
  • This study presents the estimation of crack depth by analyzing temperatures extracted from thermal images and environmental parameters such as air temperature, air humidity, illumination. The statistics of all acquired features and the correlation coefficient among thermal images and environmental parameters are presented. The concrete crack depths were predicted by four different machine learning models: Multi-Layer Perceptron (MLP), Random Forest (RF), Gradient Boosting (GB), and AdaBoost (AB). The machine learning algorithms are validated by the coefficient of determination, accuracy, and Mean Absolute Percentage Error (MAPE). The AB model had a great performance among the four models due to the non-linearity of features and weak learner aggregation with weights on misclassified data. The maximum depth 11 of the base estimator in the AB model is efficient with high performance with 97.6% of accuracy and 0.07% of MAPE. Feature importances, permutation importance, and partial dependence are analyzed in the AB model. The results show that the marginal effect of air humidity, crack depth, and crack temperature in order is higher than that of the others.

Effect of Water-Containing Conditions on Concrete Substrates on Defects of Polyurethane-based Waterproofing Materials (콘크리트 바탕면의 함수조건이 폴리 우레탄계 방수재 하자에 미치는 영향)

  • Lee, Gun-Cheol;Kim, Jae-Yeob;Kim, Young-Min;Hong, Sung-Rok;Kim, Young-Sam;Shin, Hong-Chol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • This study is to analyze the cause of the defects in polyurethane waterproofing, a material commonly used on the roof of buildings, and to determine if it has a relation with the curing conditions of humidity and temperature and the moisture content of the base structure. As a result, it was confirmed that the waterproofing coating did not adhere when the moisture content of the base plate was 10% or more. When the temperature and humidity conditions were 20℃ and 80%RH, none of the properties deteriorate but when the temperature was 40℃, 60%RH, air bubbles were formed on the surface, and at 40℃ and 80%RH, the basic properties of the dry coating film were less than the KS F 3211 performance standard.

Characteristics of Hericium erinaceus fruit body genesis in winter (동절기 노루궁뎅이버섯 자실체 발생 특성)

  • Moon, Ji-Won;Lee, Chan-Jung;Cheong, Jong-Chun;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.14 no.2
    • /
    • pp.39-43
    • /
    • 2016
  • In this study, we observed differences in the fruit body genesis in with seasonal changes. The mushrooms generated different spines even when under same environmental conditions in equivalent growth chambers during different seasons. The growth chamber conditions were set at $18^{\circ}$, 1000 ppm CO and 95% humidity for uniform primordium formation. Following this, the humidity was reduced to 85% during growth and development. The characteristics of the fruit body were measured: yield (weight), length (size), hardness, and chromaticity. Each measure was relatively compared owing standard data for. We investigated the environmental factors to assess the cause of variation in fruit body. Change in temperature and humidity were especially focused on, apart from climate that can affect mushroom growth. It was observed that temperature and humidity both influence fruit body growth. Not the absolute value of the elevation, there was a change of climate which the temperature is lowered and lowered the humidity can be assumed that the changes in the environmental conditions inside the growth chamber the mushroom growth.

Supersonic Moist Air Flow with Condensation in a Wavy Wall Channel

  • Ahn, Hyung-Joon;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.492-499
    • /
    • 2001
  • The characteristics of Prand시-Meyer expansion of supersonic flow with condensation along a wavy wall in a channel are investigated by means of experiments and numerical analyses. Experiments are carried out for the case of moist air flow in an intermittent indraft supersonic wind tunnel. The flow fields are visualized by a Schlieren system and the distributions of static pressure along the upper wavy wall are measured by a scanning valve system with pressure transducers. In numerical analyses, the distributions of streamlines, Mach lines, iso-pressure lines, and iso-mass fractions of liquid are obtained by the two-dimensional direct marching method of characteristics. The effects of stagnation temperature, absolute humidity, and attack angle of the upper wavy wall on the generation and the locations of generation and reflection of an oblique shock wave are clarified. Futhermore, it is confirmed that the wavy wall plays an important role in the generation of an oblique shock wave and that the effect of condensation on the flow fields is apparent.

  • PDF

Correlation of Critical Air Temperature for Frost Delay on a Cold Plate (냉각면 평판에서 착상 지연을 위한 임계공기온도 상관식)

  • Kim, Jung-Soo;Kim, Yoo-Yil;Kim, Ook-Joong;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1188-1195
    • /
    • 2006
  • This paper examines the critical air temperature at which frost formation does not occur on a cold plate in order to improve the efficiency of a heat pump. The critical air temperature on test points is obtained from numerical analysis and a correlation of the critical air temperature is derived as a function of frosting factors (air absolute humidity, air velocity, and cold plate temperature) by least square method. Experiments are carried out to verify the correlation proposed in this study, and the prediction obtained with the correlation agrees well with the experimental data. Based on the correlation, we propose the non-frosting regions according to frosting factors.

Desiccant Dehumidifier Selection Program (데시칸트제습기 선정프로그램)

  • Kim, Hue-Jae;Park, Seung-Tae;You, Kyoung-Rok;Lee, Hyun-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.224-229
    • /
    • 2009
  • Performance curve of the desiccant rotor is an important information when developing and selecting the desiccant dehumidifier. The effective utilization of the energy is major capacity for the system and the desiccant performance curve is a design ability for a designer. By the rotor supply contract with DRI, ECO-DRY programs would be offered. Moreover, it could make remarkable progress in the desiccant system and energy saving. It is good to introduce the programs with the amicable help of DRI.

  • PDF

The Study about Variation of Physiology Signal based on EEG due to Variation of Illumination (조도 변화에 따른 뇌파 기반 생체신호 변화에 관한 연구)

  • Kim, Myung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.55-58
    • /
    • 2012
  • By using EEG and HRV, subjects were estimated on their psychological and physiological reaction when reading psychrometric chart in 7 point century font, in an environmental test room in the condition of temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/sec], giving variation in illuminance to 0.1, 300, 600, 1000, 1300 and 1600[lux]. As a result, it was at 1300[lux] that absolute ${\alpha}$ wave, SMR, SDNN were most vitalized, and also both sides ${\alpha}$ wave asymmetry index, SEF50, HRT, stress and fatigue degree were at the lowest. It was found that a certain illuminance which minimizes psychological stress and fatigue degree while enhancing concentration and task achievement stably does exist.