• 제목/요약/키워드: Absolute distance measurement

검색결과 69건 처리시간 0.026초

ASTROMETRY OF IRAS 22555+6213 WITH VERA: A 3-DIMENSIONAL VIEW OF SOURCES ALONG THE SAME LINE OF SIGHT

  • CHIBUEZE, JAMES O.;SAKANOUE, HIROFUMI;OMODAKA, TOSHIHIRO;HANDA, TOSHIHIRO;NAGAYAMA, TAKUMI;KAMEZAKI, TATSUYA;BURNS, ROSS
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.119-120
    • /
    • 2015
  • We report results of the measurement of the trigonometric parallax of an $H_2O$ maser source in IRAS 22555+6213 with the VLBI Exploration of Radio Astrometry (VERA). The annual parallax was determined to be $0.278{\pm}0.019$ mas, corresponding to a distance of $3.66^{+0.30}_{-0.26}kpc$. Our results confirm that IRAS 22555+6213 is located in the Perseus arm. We computed the peculiar motion of IRAS 22555+6213 to be ($U_{src}$, $V_{src}$, $W_{src}$) = ($0{\pm}1$, $-32{\pm}1$, $9{\pm}1$) $km\;s^{-1}$, where $U_{src}$, $V_{src}$, and $W_{src}$ are directed toward the Galactic center, in the direction of Galactic rotation and toward the Galactic north pole, respectively. IRAS 22555+6213, NGC7538 and Cepheus A lie along the same line of sight, and are within $2^{\circ}$ on the sky. Their parallax distances, with which we derived their absolute position in the Milky Way, show that IRAS 22555+6213 and NGC7538 are associated with the Perseus arm, while Cepheus A is located in the Local arm. We compared the kinematic distances of IRAS 22555+6213 derived with flat and non-flat rotation curve with its parallax distance and found the kinematic distance derived from the non-flat rotation assumption ($-32km\;s^{-1}$ lag) to be consistent with the parallax distance.

Verification of Extended Source-To-Imager Distance (SID) Correction for Portal Dosimetry

  • Son, Jaeman;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.137-142
    • /
    • 2018
  • This study aimed to evaluate and verify a process for correcting the extended source-to-imager distance (SID) in portal dosimetry (PD). In this study, eight treatment plans (four volumetric modulated arc therapy and four intensity-modulated radiation therapy plans) at different treatment sites and beam energies were selected for measurement. A Varian PD system with portal dose image prediction (PDIP) was used for the measurement and verification. To verify the integrity of the plan, independent measurements were performed with the MapCHECK device. The predicted and measured fluence were evaluated using the gamma passing rate. The output ratio was defined as the ratio of the absolute dose of the reference SID (100 cm) to that of each SID (120 cm or 140 cm). The measured fluence for each SID was absolutely and relatively compared. The average SID output ratios were 0.687 and 0.518 for 120 SID and 140 SID, respectively; the ratio showed less than 1% agreement with the calculation obtained by using the inverse square law. The resolution of the acquired EPIDs were 0.336, 0.280, and 0.240 for 100, 120, and 140 SID, respectively. The gamma passing rates with PD and MapCHECK exceeded 98% for all treatment plans and SIDs. When autoalignment was performed in PD, the X-offset showed no change, and the Y-offset decreased with increasing SID. The PD-generated PDIP can be used for extended SID without additional correction.

6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남;박성용;서태석;권수일;윤세철
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.87-102
    • /
    • 1997
  • 목적 : 방사선량 측정시 에너지, 매질, 측정기 등의 측정 조건과 측정 프로토콜에 따라 절대 흡수선량값이 결정된다. 본 연구에서는 이러한 측정 조건의 변화와 측정 프로토콜의 차이에 따른 절대 선량 값을 구하여 비교 분석 하고자 한다. 방법 : 시멘스 선형가속기에서 발생하는 6MV 광자선을 이용하여 3개의 다른 매질(물, 고체 물팬텀, 폴리스틸렌팬텀)내에서 2개의 전리함 (PTW ion chamber, NEL ion chamber)과 2개의 전기계(Victoreen electrometer, Keithley electrometer)를 사용하여 흡수선량을 측정하였다. 매질, 전리함, 전기계등의 측정 조건을 달리하여 서로 다른 조합에 대한 측정값을 TG21, IAEA 프로토콜에 의해 각각 분석하였다. 결과 및 결론 : 2개의 전기계와 2개의 전리함 조합에 따른 TG2l 및 IAEA 의 Ngas,, ND값의 비는 평균적으로 1% 이내에서 일치하였다. 3개의 서로 다른 매질, 4개의 서로 다른 전리함 및 전기계 조합에 따른 12 가지 측정조건에 대한 흡수선량의 변화는 평균 0.6%의 차이를 보여 주였으며 임의의 전리함 및 전기계 조합에 대하여 물팬텀 및 고체물팬텀에 대한 TG21, MEA 측정법에 의한 흡수선량비의 변화 양상이 같은 양상을 보여주고 있으나 그 차이가 평균 1.96%를 보임으로서 고체물팬텀이 절대 흡수선량 측정에는 적절치 않은 것으로 사료된다. TG21 측정법에 따른 물팬텀과 폴리스틸렌팬텀을 이용한 절대 흡수선량값이 1.54%의 차이를 보임으로서 팬텀 매질에 대한 비교 factor가 필요할 것으로 사료된다. 측정매질, 전리함, 전기계 등의 여러 조건에 대한 흡수선량값의 차이가 TG21, IAEA 프로토콜에서 1% 이내의 차이를 보여 주고 있으며 상대적인 변화 양상이 측정법에 상관없이 같은 경향으로 변함으로서 측정조건이 측정법에 영향을 주지 않았음을 알 수 있다. 다만 표준 측정법을 사용할 때 팬텀에 의한 차이는 많이 날 수 있으므로 측정법에서 사용하는 표준 팬텀을 사용 할 것을 권장하며 이것이 어려운 경우는 병원에서 사용하는 팬텀에 대한 보정값을 자체적으로 구하여 사용하는 것이 오차를 줄일 수 있을 것으로 사료된다.

  • PDF

세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향 (Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy)

  • 김선영;이두현;조정근;정도형;김호식;최계숙
    • 대한방사선치료학회지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 목 적: 세기조절 방사선치료의 환자별 정도관리는 이온전리함을 이용한 일정 지점에서의 절대 선량 측정과 필름을 이용한 상대 선량측정의 두 단계로 구성된다. 이온전리함을 이용한 절대 선량 측정은 동일한 지점에서 치료계획상의 점선량과 실제 측정 점선량 간의 일치도에 대한 정보를 제공한다. 일반적으로 정확한 점선량을 측정하기 위해 volume이 작은 0.015 cc 이온전리함(pin point chamber, PTW, Germany)을 사용하고 있다. 그러나 이 경우 이온전리함의 볼륨이 작아 선량의 오차가 크게 나타나는 경우도 있어, 적합한 볼륨의 이온전리함 사용이 권고되기도 한다. 따라서 볼륨이 다른 세 가지의 이온전리함을 이용하여 점선량을 측정하여 치료계획상의 점 선량과 비교해 보고, 0.015 cc 이온전리함을 이용한 세기조절 방사선치료에서의 절대 점선량 측정의 유효성을 평가해 보고자 한다. 대상 및 방법: 두경부(Head & Neck) 종양의 세기조절 방사선치료가 요구되는 환자 6명을 대상으로 Sliding-window 방법의 IMRT 치료계획을 수립하였으며 치료기는 21EX(Varian, USA) 선형가속기의 6 MV 광자선을 사용하였다. 측정 조건은 120 millenium MLC를 이용하여 Gantry 0도에서 300 MU/min의 선량률로 선원-이온전리함(source-axis-distance)거리를 100 cm, 고체팬텀의 표면으로부터 5 cm 깊이에 이온전리함을 위치시켰다. 치료계획용 컴퓨터(CAD-Plan, USA)에서 결정된 결과를 0.015 cc(pin point, type 31014, PTW, Germany), 0.125 cc(micro type 31002, PTW, Germany ), 0.6 cc(famer type 30002, PTW, Germany) 전리함에 각각 조사하여 측정치를 비교 분석하였다. 측정점은 선량값의 변화가 상대적으로 적은 선량 저변동 영역(Low-gradient area)에 위치시켰다. 결 과: 각각의 이온전리함을 이용하여 측정한 결과 0.015 cc의 경우 평균 ${\pm}0.91%$, 0.125 cc의 경우 ${\pm}0.52%$, 0.6 cc의 경우 ${\pm}0.76%$로 0.125 cc 이온전리함의 경우가 모든 측정조건에서 가장 적은 오차를 보였다. 결 론: 세기조절 방사선치료에 있어서 선량의 평가는 매우 중요하다. 방사선치료가 정밀해지는 만큼 정확한 선량평가가 이루어져야 한다. 점선량을 평가하기 위해 제작된 0.015 cc 이온전리함은 작은 출력신호와 큰 신호 대 잡음비가 절대 선량 측정 시 선량오차를 발생시키는 큰 요인으로 작용할 수 있다. 반면에 이온전리함의 볼륨이 큰 경우 출력신호가 크므로 정확한 선량을 반영할 수 있으나, 작은 측정점에 이온전리함을 정확히 위치시키기 어려워 절대 점선량을 측정하기 어려운 단점이 있다. 따라서 본 연구의 결과에서 본 바와 같이 세기조절 방사선치료의 절대 점선량 측정에는 오차가 상대적으로 적은 0.125 cc 이온전리함의 사용이 고려되어야 한다.

  • PDF

Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

  • Vernucci, Roberto Antonio;Aghazada, Huseynagha;Gardini, Kelly;Fegatelli, Danilo Alunni;Barbato, Ersilia;Galluccio, Gabriella;Silvestri, Alessandro
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.159-169
    • /
    • 2019
  • Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.

9930M Loran신호 이용 근거리 ASF 측정 (Short Distance ASF Measurement by using 9930M Loran Signal)

  • 양성훈;이창복;이종구;김영재;이상정
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2010년도 춘계학술대회
    • /
    • pp.370-371
    • /
    • 2010
  • Loran(LOang RAnge Navigation) 신호에 의한 항법은 GPS(Global Positioning System) 활성화 전까지 주요한 항법시스템으로 이용되어 왔다. 특히 선박들 항행하는데 있어서 필수적인 기능을 담당하였다. 그러나 산업의 발전과 더불어 항행 외에 항만 근접과 육상에서의 항법 그리고 정밀시각활용과 같은 분야에서는 지금의 항법정확도 보다 우수한 정확도가 필요하다. 그 정확도를 향상시킬 수 있는 방법은 Loran 송신국과 사용자 위치 사이의 전파지연 즉, ASF (Additional Secondary Factor)를 정확히 측정하는 것이다. 본 연구에서는 우리나라에서 방송하는 9930M(포항)과 같이 TOC(Time of Coincidence) 테이블이 없는 방송시스템에서 절대시간 지연을 측정할 수 있는 기법을 개발하였으며, 송신국으로부터 몇 개의 측정지정에서 ASF를 측정한 결과를 제시한다.

  • PDF

In-situ measurement of railway-traffic induced vibrations nearby the liquid-storage tank

  • Goktepe, Fatih;Kuyuk, Huseyin S.;Celebi, Erkan
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.583-589
    • /
    • 2017
  • In this study, result of a field investigation of railway traffic-induced vibrations is provided to examine acceptability levels of ground vibration and to evaluate the serviceability of a liquid-storage tank. Free field attenuation of the amplitudes as a function of distance is derived by six accelerometers and compared with a well-known half-space Bornitz's analytical solution which considers the loss of the amplitude of waves due to geometrical damping and material damping of Rayleigh. Bornitz's solution tends to overlap vertical free field vibration compared with in-situ measured records. The vibrations of the liquid-storage tank were compared with the USA, Federal Transportation Railroad Administration (FTA) criteria for acceptable ground-borne vibrations and with the criteria in DIN 4150-3 German standard. Comparing the thresholds stated in DIN 4150-3, absolute peak particle velocities are within the safe limits, however according to FTA velocity level at the top of the water tank exceeds the allowable limits. Furthermore, it is intended to indicate experimentally the effect of the kinematic interaction caused by the foundation of the structure on the free-field vibrations.

측량과 현방식 궤도틀림 측정 비교 (Comparison of Chord method with Surveying in Track irregularity Measurement)

  • 이지하;이상진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1647-1652
    • /
    • 2008
  • Track geometry consists of tangent and curved lines, which caused undesirable changes in initial track geometry by traffic loads. The bigger the changes are, the worse the riding comfort and running stability of train. This is so-called track irregularity and is the most important quality parameters of ballasted track. To be able to objectively assess track irregularity, track geometry should be able to be measured. Practically, railway companies use moving chord method, this method determine versine values via a chord. The versine is the vertical distance to curve measured in the middle of the chord. This type of method measures only versine of track irregularity curve by transfer function from specific property of measuring tool. In this report, review the characteristics of two types of measuring tools by comparing the measurements. The one is GRP-1000 system, optical surveying system with Total station and lazar prism trolly. This calculates track geometry by surveying absolute coordinates of two points each on both rail heads. The other is Trackmaster, measures versine with 2m of chord length.

  • PDF

Wilson-Bappu Effect: Extended to Surface Gravity

  • 박선경;강원석;이정은;이상각
    • 천문학회보
    • /
    • 제38권1호
    • /
    • pp.59.2-59.2
    • /
    • 2013
  • Wilson and Bappu found a tight correlation between the stellar absolute visual magnitude (MV) and the width of the Ca II K emission line for late-type stars in 1957. Here, we revisit the Wilson-Bappu relationship (hereafter, WBR) to claim that WBR can be an excellent indicator of stellar surface gravity of late-type stars as well as a distance indicator. We have measured the width (W) of the Ca II K emission line in high resolution spectra of 125 late-type stars, which were obtained with Bohyunsan Optical Echelle Spectrograph (BOES) and adopted from the UVES archive. Based on our measurement of the emission line width (W), we have obtained a WBR of $M_V=33.76-18.00{\log}W$. In order to extend the WBR to be a surface gravity indicator, the stellar atmospheric parameters such as effective temperature ($T_{eff}$), surface gravity (logg), metallicity ([Fe/H]), and micro-turbulence (${\xi}_{tur}$) have been derived from the self-consistent detailed analysis using the Kurucz stellar atmospheric model and the abundance analysis code, MOOG. Using these stellar parameters and logW, we found that ${\log}g=-5.85\;{\log}W+9.97\;{\log}T_{eff}-23.48$ for late-type stars.

  • PDF

오구돌기하 충돌 증후군 유무에 따른 초음파를 이용한 상완오구돌기 계측 (Ultrasound Measurement of Coracohumeral Distance in Patients with or without Subcoracoid Impingement)

  • 장석환;김상범
    • 대한정형외과 초음파학회지
    • /
    • 제7권1호
    • /
    • pp.20-27
    • /
    • 2014
  • 목적: 오구돌기하 충돌증후군은 전방 견관절 통증의 원인 중 하나로 알려져 있지만, 현재까지 표준이 되는 영상학적 진단 기준이 없다. 본 연구는 오구돌기하 충돌증후군이 있는 환자군에서 상완-오구돌기간의 거리(CHD)가 좁을 것이라는 가정하에, 오구돌기하 충돌증후군 유무에 따른 상완-오구돌기간 거리를 분석하였다. 대상 및 방법: 견봉하 충돌증후군 환자 124명을 분석하였다. 이학적 검사 및 초음파를 이용한 오구돌기하 주사 검사를 통하여 확진 된 오구돌기하 충돌증후군의 환자군(n=28)을 견봉하 충돌증후군만 있는 군(n=96)과 비교하였다. 견관절의 강직이나, 회전근개 파열이 있는 환자는 대상에서 제외되었다. 상완-오구돌기간의 절대적 거리는 초음파의 내회전과 중립위 자세 및 자기공명 횡단면 영상에서 측정하였다. 또한 내회전과 중립위의 상완-오구돌기간 거리의 차이와, 중립위의 상완-오구돌기간 절대적 거리와의 비율로 정의된 거리 차이의 상대적 비율(relative ratio of distance difference;RRDD)도 함께 측정하였다. 결과: 중립위의 거리는 초음파 영상과 자기공명영상에서 비슷한 값을 보였고(p>0.05), 두 측정값의 두 군간에 유의한 차이는 없었다(p>0.05). 초음파영상을 통해 측정한 두 군간의 중립위 거리 차이는 유의수준에 가까웠다(p=0.07). 상완의 위치에 따른 상완-오구돌기간 거리의 차이는 두 군간에 통계학적 유의성이 없었다. 하지만, RRDD 값은 오구돌기하 충돌증후군 환자군에서 유의하게 더 컸다(p<0.05). 결론: 오구돌기하 충돌 증후군 환자군과 대조군 사이의 상완-오구돌기간 거리 차이의 유의한 차이가 없었다. RRDD값은 오구돌기하 충돌 증후군 환자군에서 더 높았으며, 따라서 오구돌기하 충돌증후군이 있는 환자를 평가할 때 개인의 내회 전시 상완-오구돌기간 상대적 거리도 함께 고려해야 한다.

  • PDF