• Title/Summary/Keyword: Absolute Position Measurement

Search Result 81, Processing Time 0.028 seconds

Robotic Workplace Calibration Using Teaching Data of Work-Piece Fixed in Robotic Workplace for Robot Off-line Programming (로봇 오프라인 프로그래밍을 위한 작업장에 고정된 공작물 교시 정보를 이용한 로봇작업장 보정)

  • Jeong, Jun Ho;Kuk, Kum Hoan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.6
    • /
    • pp.615-621
    • /
    • 2013
  • The robot calibration has greatly improved the absolute accuracy of the industrial robot. However, the accuracy of the relative positions of robotic tool-tip at work-points on a work-piece is only slightly corrected by the robot calibration since there has been no practical method to eliminate the elements of the setup position errors at a robotic workplace. A robotic workplace calibration is demonstrated in this paper to minimize the relative position errors between a robot tool-tip and the work-point on a work-piece. The existing teaching and playback method has been developed for the robotic workplace calibration. This paper uses the work-piece fixed in a robotic work-place as measurement equipment instead of a special robot measurement equipment for the robotic workplace calibration. The positive effect of the robotic workplace calibration is supported by the results of computer simulation on an ideal robotic workplace model and an experiment at the actual robotic workplace.

Performance Evaluation of a Compressed-State Constraint Kalman Filter for a Visual/Inertial/GNSS Navigation System

  • Yu Dam Lee;Taek Geun Lee;Hyung Keun Lee
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.2
    • /
    • pp.129-140
    • /
    • 2023
  • Autonomous driving systems are likely to be operated in various complex environments. However, the well-known integrated Global Navigation Satellite System (GNSS)/Inertial Navigation System (INS), which is currently the major source for absolute position information, still has difficulties in accurate positioning in harsh signal environments such as urban canyons. To overcome these difficulties, integrated Visual/Inertial/GNSS (VIG) navigation systems have been extensively studied in various areas. Recently, a Compressed-State Constraint Kalman Filter (CSCKF)-based VIG navigation system (CSCKF-VIG) using a monocular camera, an Inertial Measurement Unit (IMU), and GNSS receivers has been studied with the aim of providing robust and accurate position information in urban areas. For this new filter-based navigation system, on the basis of time-propagation measurement fusion theory, unnecessary camera states are not required in the system state. This paper presents a performance evaluation of the CSCKF-VIG system compared to other conventional navigation systems. First, the CSCKF-VIG is introduced in detail compared to the well-known Multi-State Constraint Kalman Filter (MSCKF). The CSCKF-VIG system is then evaluated by a field experiment in different GNSS availability situations. The results show that accuracy is improved in the GNSS-degraded environment compared to that of the conventional systems.

Indoor Navigation System for Visually Impaired Persons Using Camera and Range Sensors (카메라와 거리센서를 이용한 시각장애인 실내 보행안내 시스템)

  • Lee, Jin-Hee;Shin, Byeong-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.4
    • /
    • pp.517-528
    • /
    • 2011
  • In this paper, we propose an indoor navigation system that can do walk safely to the destination for visually impaired persons. The proposed system analyzes images taken with the camera finds the ID of the marker to identify the absolute position of the pedestrian. Using the distance and angle obtained from IMU(Inertial Measurement Unit) accelerometer sensor and a gyro sensor, the system decides the relative position of a pedestrian for the previous position to determine the next direction. At the same time, we simplify a complex spatial structure in front of user by means of ultrasonic sensors and determine an avoidance direction by estimating the patterns. Then, it uses a few IR(Infrared Rays) sensors to detect stair. Our system offers position of visually impaired persons incorporating multiple sensors and helps users to arrive to destination safely.

Multiple-Point-Diffraction Interferometer : Error Analysis and Calibration (거친 표면 형상측정을 위한 점광원 절대간섭계의 오차해석과 시스템 변수의 보)

  • Kim, Byoung-Chang;Kim, Seung-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.361-365
    • /
    • 2005
  • An absolute interferometer system with multiple point-sources is devised for tile 3-D measurement of rough surface profiles. The positions of the point sources are determined to be the system parameters that influence the measurement accuracy, so they are calibrated precisely prior to performing actual measurements. For the calibration, a CCD camera composed of a two-dimensional array of photo-detectors was used. Performing optimization of the cost function constructed with phase values measured at each pixel on the CCD camera, the position coordinates of each point source is precisely determined. Measurement results after calibration performed for the warpage inspection of chip scale packages (CSPs) demonstrate that the maximum discrepancy is 9.8 mm with a standard deviation o( 1.5 mm in comparison with the test results obtained by using a Form Taly Surf instrument.

Reproducibility of the Isokinetic Joint Torque as a Rotator Cuff Weakness Test Protocol in Patients With Rotator Cuff Tendinitis

  • Kim, Soo-yong;Oh, Jae-seop
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.21-29
    • /
    • 2017
  • Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.

A Study on Inspecting Position Accuracy of DACS Pintle (위치자세제어장치의 핀틀 위치정확도 점검 방안 연구)

  • Tak, Jun Mo
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.57-64
    • /
    • 2021
  • In the study, to minimize the error on guided control of the KV (Kill Vehicle) and to secure the hit-to-kill performance, a position accuracy inspection for the DACS (Divert and Attitude Control System) actuation system was proposed. The accuracy performance of the DACS actuation system is one of the most important factors in the interception of ballistic missiles. In order to validate actuation control accuracy of DACS system, an inspection item was set for position accuracy, and the inspection system was designed for DACS pintle. To measure the absolute position value of the DACS pintle, an external measurement system was developed using laser displacement sensors. The inspection system was designed so that it can be compared with the actuation command in real time. The proposed position accuracy inspection system can be inspected not only in a DACS system but also in missile system level. The position accuracy inspection was performed using the designed inspection system, and analysis of the inspection result.

A Study Absolute Position Estimation of Sound Source (3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구)

  • Kim, Chun-Duk;Sim, Dong-Youn;Jang, Bee;Lee, Chai-Bong;Cha, Kyung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.76-82
    • /
    • 1997
  • The paper describes simulations and experimental results using a measuring system which utilizes the acoustic holographic method in order to exactly estimate an absolute position of a sound source. The measuring surface is installed to satisfy with a far field to the sound source and is composed of linear arrayed seven microphones. A measurement is simultaneously recorded by a reference microphone setting up a neighbour sound source and the linear arrayed seven microphones which are moved to the same interval. An absolute position of sound source is estimated by the cross-spectrum method to the received sounds between a reference and the measuring microphones. Phase differences of each microphone and time delays during scanning are compensated to the reference microphone and the measuring time of the first column. An optimal interval for each microphone in the measuring surface is decided by a numerical simulation. A source signal makes use of a sinusoid, and S/N ratio is 30dB in the experiment. The optimal microphone's interval in the simulation and the experiment is decided in order to satisfy with the Nyquist space sampling condition related to the wave length of 2kHz sinusoid. Mainlobe width of a estimated 3D hologram in the case of 2kHz source signal is decreased to 87% and 30% in comparison to 500Hz and 1kHz, and then a valid of simulation results is confirmed. Therefore, we verified a utilization of the study for a sound source estimation using 3ㅇ acoustic holographic method.

  • PDF

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

Navigation System of UUV Using Multi-Sensor Fusion-Based EKF (융합된 다중 센서와 EKF 기반의 무인잠수정의 항법시스템 설계)

  • Park, Young-Sik;Choi, Won-Seok;Han, Seong-Ik;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.7
    • /
    • pp.562-569
    • /
    • 2016
  • This paper proposes a navigation system with a robust localization method for an underwater unmanned vehicle. For robust localization with IMU (Inertial Measurement Unit), a DVL (Doppler Velocity Log), and depth sensors, the EKF (Extended Kalman Filter) has been utilized to fuse multiple nonlinear data. Note that the GPS (Global Positioning System), which can obtain the absolute coordinates of the vehicle, cannot be used in the water. Additionally, the DVL has been used for measuring the relative velocity of the underwater vehicle. The DVL sensor measures the velocity of an object by using Doppler effects, which cause sound frequency changes from the relative velocity between a sound source and an observer. When the vehicle is moving, the motion trajectory to a target position can be recorded by the sensors attached to the vehicle. The performance of the proposed navigation system has been verified through real experiments in which an underwater unmanned vehicle reached a target position by using an IMU as a primary sensor and a DVL as the secondary sensor.

A Study for Beamforming Acoustic Holographic Method Using Linear Arrayed Microphones (직선 배열형 마이크로폰 어레이를 이용한 빔포밍 음향홀로그래픽법에 관한 연구)

  • Kim, Chun-Duck;Sim, Dong-Youn;Jang, Bee;Cha, Kyung-Hwan;Lee, Chai-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.3-10
    • /
    • 2000
  • This paper proposes acoustic holographic measuring system to estimate an absolute position of sound source. Using the measured signals, the estimation of the position is calculated by the Cross-spectrum algorithm of the beamformed signal and a linear arrayed microphone's signals. As the results of comparing the reference microphone method with beamforming method through the measurement of sound field, the beamforming acoustic holographic method is progressed above 20 percent than that of a reference microphone method in the resolution, and the utility of the proposed system could be confirmed.

  • PDF