• 제목/요약/키워드: Abnormal value

Search Result 608, Processing Time 0.024 seconds

Analysis of Abnormal Signals for Induction Motor according to Operating Status of Fire Pumps (소방펌프의 운전상태에 따른 유도전동기의 이상 신호 분석)

  • Ku, Bonhyu;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.20-27
    • /
    • 2022
  • This article aims to develop an algorithm that detects fire pump defects by analyzing the current signals of an induction motor, which are triggered by changes in the flow rate and pressure of multistage volute pumps that are used for fire services. The operational status of the pumps was categorized into three: first, normal operation; second, a defect that is caused by a change in the current value; and third, a defect occasioned by a change in current, pressure, and flow rate. When a fire pump was in normal operation, the motor's operating current was measured between 5.06 A and 6.9 A, the flow rate was estimated at 0-0.27 m3/min, and the pressure ranged from 0 to 0.47 MPa. In the event that a defect was caused by an abnormal current value in the motor, it was attributed to the pump's adherence. Furthermore, if there was no source of water, the defect was considered to have been induced by phase-loss operation, no-load operation, or run-stop operation, with the current value of each scenario being measured at > 52.8 A, < 4.13 A, > 45.15 A, and < 3.8 A, respectively, placing its overall range between 0 and 50 A. The sources of defects were detected based on an analysis of the flow rate, pressure, and current, which represent the following causes: air inflow into the casing, inadequate suction of water, and reverse-phase operation, respectively. Each cause entailed the following values: when air seeped into the casing, the pressure was measured at 0.24 MPa irrespective of changes in the flow rate; when there was inadequate suction of water, the pressure was recorded between 0 and 0.05 MPa despite changes in the flow rate; and when the power line's reverse-phase loss was the cause of the defect, the pressure was measured at 0.33 MPa for a flow rate of 0 L/min, and a higher flow rate decreased the pressure to nearly 0 MPa. The results of this study will enable engineers to develop a pump defect detection algorithm that is based on an analysis of current, and this algorithm will facilitate the execution of a program that will control a fire pump defect detection system.

A Study on the guidelines for Tasty and Healthy Drinking Water Supply (청정급수를 위한 쾌적수질기준 설정에 관한 기초조사 연구)

  • 금영환;문량조;유재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.106-125
    • /
    • 1995
  • Recently, in accordance with elevation of life style and economics, the public demand became increasingly concerned about drinking water quality. Without an adequate supply of safe water, healthy and comfortable life could not exist. Therefore, the purpose of this study is to provide the guidelines and the basic informations to enable supply of clean, tasty and healthy drinking water acceptable for various demands. We analyzed the quality of tap water, mineral water, purified tap water using home tap water purifier. And we researched on the sense of the public complaint over the tap water. We proposed several items relating to the comfortableness of water quality and the target value. Also we presented a case of water supply system for purity and the points at problem The items and target value are as follows 1. turbidity : not more than 1 degree 2. dry residue : $30~200{\;}mg/{\ell}$ 3. hardness : $10~100mg/{\ell}$ 4. free carbon dioxide : not more than $20mg/{\ell}$ 5. $KMnO_{4}$ consumption not more than $3mg/{\ell}$ 6. odor threshold not abnormal 7. residual chlorine : not more than $0.4mg/{\ell}$ 8. water temperature' not more than $20^{\circ}C$ 9. manganese : not more than $0.01mg/{\ell}$ 10. iron : not more than $0.02mg/{\ell}$ 11. aluminum : not more than $0.1mg/{\ell}$

  • PDF

Temperature Dependent Current Transport Mechanism in Graphene/Germanium Schottky Barrier Diode

  • Khurelbaatar, Zagarzusem;Kil, Yeon-Ho;Shim, Kyu-Hwan;Cho, Hyunjin;Kim, Myung-Jong;Kim, Yong-Tae;Choi, Chel-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • We have investigated electrical properties of graphene/Ge Schottky barrier diode (SBD) fabricated on Ge film epitaxially grown on Si substrate. When decreasing temperature, barrier height decreased and ideality factor increased, implying their strong temperature dependency. From the conventional Richardson plot, Richardson constant was much less than the theoretical value for n-type Ge. Assuming Gaussian distribution of Schottky barrier height with mean Schottky barrier height and standard deviation, Richardson constant extracted from the modified Richardson plot was comparable to the theoretical value for n-type Ge. Thus, the abnormal temperature dependent Schottky behavior of graphene/Ge SBD could be associated with a considerable deviation from the ideal thermionic emission caused by Schottky barrier inhomogeneities.

Assessment of Operative Risks of Pneumonectomy (전폐절제술에 있어서 수술 위험인자의 평가)

  • Jeong, Gyeong-Yeong;Kim, Gil-Dong
    • Journal of Chest Surgery
    • /
    • v.28 no.5
    • /
    • pp.464-470
    • /
    • 1995
  • From Jan 1988 to Dec 1993, 196 consecutive patients with various pulmonary diseases underwent pneumonectomy. Mean age was 54.0 years[range:7-74 . The underlying diseases were lung cancer[154 cases , destroyed lung[29 cases with pulmonary tuberculosis or empyema thoracis and others[13 cases . The overall mortality and complication rate were 5.6% and 14.8%. In the groups of more than and less than 60 years of age, there was significant differences in mortality rate[P=0.004 . In the group of pneumonectomy and pleuropneumonectomy, there was no significant differences in mortality[P=0.164 and complication rate[P=0.052 . In the group of normal and abnormal EKG, there was no significant differences in mortality[P=0.560 and complication rate[P=0.693 . In the preoperative FEV1, preoperative FVC and predicted postoperative FEV1, prognostic cut-off points were 1800cc, 2600cc and 1300cc, and at points, positive predicted value were 12.3%, 10.5%.and 7.7% and negative predicted value were 97.8%, 98.3% and 96.2% respectively. The preoperative FEV1 is the most reliable indicator in assessment of prognosis of pneumonectomy.

  • PDF

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

Nominal Price Anomaly in Emerging Markets: Risk or Mispricing?

  • HOANG, Lai Trung;PHAN, Trang Thu;TA, Linh Nhat
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.9
    • /
    • pp.125-134
    • /
    • 2020
  • This study examines the nominal price anomaly in the Vietnamese stock market, that is, whether stocks with low nominal price outperform stocks with high nominal price. Using a sample of all 351 companies listed on the Ho Chi Minh Stock Exchange (HOSE) from June 2009 to March 2018, we confirm our hypothesis and document that cheaper stocks yield higher subsequent abnormal returns. The results are robust after controlling for various stock characteristics that have been documented to be value-relevant in prior literature, including firm size, book-to-market ratio, intermediate-term momentum, short-term reversal, skewness, market risk, idiosyncratic risk, illiquidity and extreme daily returns, using both the portfolio analysis and the Fama-MacBeth cross-sectional regression. The negative effect persists in the long term (i.e., after up to 12 months), implying a slow adjustment of stock prices to their intrinsic value. Further analysis show that the observed nominal price anomaly is mainly driven by mispricing but not a latent risk factor proxied by stock price, thus the observed anomaly reflects a mispricing but not a fundamental risk. The study highlights the irrational behaviour of investors and market inefficiency in the Vietnamese stock market and provides important implication for investors in the market.

A Plan to Ensure Safety of Electric Installation in Empty houses During Normal Working Hours (부재수용가의 전기설비에 대한 안전확보 방안)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, In-Soo;Bae, Seok-Myung;Cho, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.25-26
    • /
    • 2006
  • An electrical fault is defined as any abnormal condition caused by reduction in the insulation strength between energized conduction parts and ground or any grounded part of an electrical system. Failure of solid insulation can be caused by excessive mechanical tension being applied on the insulation, harsh service environment, aging, and also by corona phenomena. The number of empty houses during normal working hours is rising. As a result, the number of uninspected electric installation for general use is increasing. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value can not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed.

  • PDF

Determination of cut-off value by receiver operating characteristic curve of norquetiapine and 9-hydroxyrisperidone concentrations in urine measured by LC-MS/MS

  • Kim, Seon Yeong;Shin, Dong Won;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.78-86
    • /
    • 2021
  • The objective of this study was to investigate urinary cut-off concentrations of quetiapine and risperidone for distinction between normal and abnormal/non-takers who were being placed on probation. Liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was employed for determination of antipsychotic drugs in urine from mentally disordered probationers. The optimal cut-off values of antipsychotic drugs were calculated using receiver operating characteristic (ROC) curve analysis. The sensitivity and specificity of the method for the detection of antipsychotic drugs in urine were subsequently evaluated. The area under the ROC curve (AUC) was 0.927 for norquetiapine and 0.791 for 9-hydroxyrisperidone, respectively. These antipsychotic drugs are classified readily in the ROC curve analysis. The cut-off values for distinguishing regular and irregular/non-takers were 39.1 ng/mL for norquetiapine and 67.9 ng/mL for 9-hydroxyrisperidone, respectively. The results of this study suggest the cut-off values of quetiapine and risperidone were highly useful to distinguish regular takers from irregular/non-takers.

Detection and Trust Evaluation of the SGN Malicious node

  • Al Yahmadi, Faisal;Ahmed, Muhammad R
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.6
    • /
    • pp.89-100
    • /
    • 2021
  • Smart Grid Network (SGN) is a next generation electrical power network which digitizes the power distribution grid and achieves smart, efficient, safe and secure operations of the electricity. The backbone of the SGN is information communication technology that enables the SGN to get full control of network station monitoring and analysis. In any network where communication is involved security is essential. It has been observed from several recent incidents that an adversary causes an interruption to the operation of the networks which lead to the electricity theft. In order to reduce the number of electricity theft cases, companies need to develop preventive and protective methods to minimize the losses from this issue. In this paper, we have introduced a machine learning based SVM method that detects malicious nodes in a smart grid network. The algorithm collects data (electricity consumption/electric bill) from the nodes and compares it with previously obtained data. Support Vector Machine (SVM) classifies nodes into Normal or malicious nodes giving the statues of 1 for normal nodes and status of -1 for malicious -abnormal-nodes. Once the malicious nodes have been detected, we have done a trust evaluation based on the nodes history and recorded data. In the simulation, we have observed that our detection rate is almost 98% where the false alarm rate is only 2%. Moreover, a Trust value of 50 was achieved. As a future work, countermeasures based on the trust value will be developed to solve the problem remotely.

Validation of Sensing Data Based on Prediction and Frequency (예측 및 빈도 기반의 센싱데이터 신뢰도 판단 기법)

  • Lee, SunYoung;Kim, Ki-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1398-1405
    • /
    • 2016
  • As wireless sensor networks become eligible as well as useful in several controled systems where surrounding environments are likely to be monitored, their stabilization become important research challenge. Generally, stabilization is mostly dependent on reliability of sensing value. To achieve such reliability in wireless sensor networks, the most of previous research work have tendency to deploy the same type of multiple sensor units on one node. However, these mechanisms lead to deployment problem by increasing cost of sensor node. Moreover, it may decrease reliability in the operation due to complex design. In order to solve this problem, in this paper, we propose a new validation scheme which is based on prediction and frequency value. In the proposed scheme, we take into exceptional cases account, for example, outbreak of fire. Finally, we demonstrate that the proposed scheme can detect abnormal sensing value more than 13 percent as compared to previous work through diverse simulation scenarios.