• Title/Summary/Keyword: Abnormal condition

Search Result 713, Processing Time 0.026 seconds

Study on Selection of HTS Wire for Fabrication of Fault Current-limiting Type HTS Cables (사고전류 제한형 초전도케이블 제작을 위한 초전도 선재 선정에 관한 연구)

  • Heo, Soung-Ouk;Kim, Tae-Min;Han, Byung-Sung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.12
    • /
    • pp.904-908
    • /
    • 2013
  • When an abnormal condition occurs due to a fault current at a consumer location where electricity is supplied through a high-capacity and high-$T_c$ superconducting(HTS) cable, the HTS cable would be damaged if there is no appropriate measure to protect it. Therefore, appropriate measures are needed to protect HTS cables. The fault-current-limiting HTS cable that was suggested in this study performs an ideal transport current function in normal operations and plays a role in limiting a fault current in abnormal operation (i.e., when a fault current is applied). It has a structure that facilitated its self-current-limiting ability through device change and reconfiguration in the existing HTS cable without extra switching equipment. To complete this structure, it is essential to investigate about the selection of the superconducting wire. Therefore, in this paper, HTS wire using two types of different stabilization layer is compared and examined the stability and current limiting properties under the existence of a fault current.

The Analysis of 278 Cases Who were Medicated with Cheonga-won (청아원을 사용한 환자 278례에 대한 증례 분석)

  • Kang, Jae-Hui;Lee, Hyun;Choi, Joo-Young;Yoon, Kwang-Sik
    • Journal of Acupuncture Research
    • /
    • v.28 no.1
    • /
    • pp.93-100
    • /
    • 2011
  • Objectives : The purpose of this study is to observe the general distribution that was medicated with Cheonga-won. Methods : The 278 patients who were medicated with Cheonga-won more than two weeks in Cheonan oriental hospital, Daejeon university from December 2007 to December 2010 were observed. The other general oriental therapys were also carried out according to individual condition. The 278 patients were analyzed according to the distribution of sex, age, the period of medication, symptoms, the change of VAS score and T-score, side effects and abnormal reactions. Results : 1. Cheonga-won was mostly used for Shin-huh, which induces lower back pain, knee pain, vertigo, dysuria, tinnitus. 2. More patients in their fifties, sixties and seventies were prescribed with the medication than those in their thirties and forties. 3. After medication with Cheonga-won, there are tendency in reduce chronic pain. 4. After medication with Cheonga-won, there are tendency in increase BMD(bone mineral density). 5. There are no side effects and abnormal reaction cases that related with Cheonga-won. Conclusions : Cheonga-won was used in Shin-huh symptoms, and may be effective in reduce chronic pain, improve Shin-huh symptoms and increase BMD.

A Study on the Backfire and Abnormal Combustion in the Free-piston Hydrogen Fueled Engine (프리피스톤 수소기관의 역화 및 이상연소에 관한 연구)

  • Kim, K.M.;Park, S.W.;Lee, J.H.;Noh, K.C.;Lee, J.T.;Lee, Y.K.
    • Journal of Hydrogen and New Energy
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • The free-piston hydrogen fueled engine is estimated as the next generation power system which can obtain high efficiency and low emission, simultaneously. In order to develop the free-piston hydrogen fueled engine, it is necessary to stable the combustion. The engine combustion, backfire and knock phenomenons were studied by using RICEM for researching combustion characteristics of free-piston engine. As the results, backfire occurrence was not observed in the free-piston engine under limited experimental condition. And knocking occurred in case of higher cylinder wall temperature.

Internal Flow Characteristics in the Draft Tube of a Francis Turbine

  • Wei, Qingsheng;Zhu, Baoshan;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.618-626
    • /
    • 2012
  • Suppression of abnormal flow phenomena in the Francis hydro turbine is very important to improve the turbine performance. Especially, as cavitation and cavitation surge makes serious problems when the turbine is operated in the range of partial flow rate, optimum method of suppressing the abnormal flow characteristics is required necessarily. Moreover, as swirl flow in the draft tube of the Francis turbine decreases pressure at the inlet of the draft tube, suppression of the swirl flow can be an useful method of suppressing the occurrence of cavitation. In order to clarifying the possibility of suppressing the swirl flow by J-Groove in the draft tube, a series of CFD analysis has been conducted in the range of partial load, designed condition and excessive flow rate of a Francis turbine. A kind of J-Groove is designed and applied to the draft tube of the Francis hydro turbine model. The pressure contours, circumferential velocity vectors and vortex core regions in the draft tube are compared by the conditions with or without J-Groove. In addition, a group of data about the velocity in the draft is presented to show the influence of J-Groove.

Development of an Engine Oil Quality Monitoring System (엔진오일 유전상수 변화량 측정에 의한 엔진오일 품질 모니터링 시스템 개발)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.125-133
    • /
    • 2011
  • The purpose of this study is to develop an engine oil quality monitoring system to warn the abnormal condition of engine oil. To do this, first of all, it is needed a personal controller development to measure the capacitance of a pre-developed engine oil deterioration detection sensor integrated with an oil filter. To measure the capacitance of engine oil in the sensor, it is used the way measuring the electric charging time in a capacitor by impressing DC volt. This method has merits on cost and signal stability. The measured capacitance is compensated by comparing with the one measured by an impedance analyzer. Also, using the dielectric constant gained by an impedance analyzer, the calculating equation of the dielectric constant of engine oil related with the currently developed sensor is decided. Then, the deterioration degree of engine oil is estimated according to the change rate of dielectric constant between green oil and used oil. Finally, using this dielectric constant information together with engine oil temperature and pressure, the currently developed engine oil quality monitoring system is to tell the abnormal state of engine oil.

Cor triatriatum with left superior vena cava[Report of a case] (좌측 상공정맥을 동반한 삼심방증 1례 보고)

  • 박병순
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.293-298
    • /
    • 1985
  • Cor triatriatum is a rare congenital malformation of the heart in which a septum stretches in a transverse plane through the left atrium, thus creates two left atrial subchambers. The upper one connects with the pulmonary veins, and the lower connects with the left ventricles. Due to the rarity of, and difficulty in diagnosing car triatriatum, data on the surgery of the disease are of necessity and very limited. A case of cor triatriatum combined with atrial septal defect and persistent left superior vena cava was experienced in November, 1984 in Chonnam University Medical School. There was a transverse septum in the left atrium below atrial septal defect, all pulmonary veins were drained into the upper chamber of the left atrium which connected with the right atrium via atrial septal defect and the lower chamber via an oval opening[8mm] in the abnormal septum and the lower chamber was connected with the left atrial appendage, and the left ventricle via mitral valve. There was persistent left superior vena cava drained to left atrium and coronary sinus. The abnormal transverse septum within the left atrium was completely excised and the atrial septal defect was repaired with Woven Dacron patch. The post-operative course was not eventful and the patient was discharged to home with good result on the 15th postoperative day, and has been in good condition upto now.

  • PDF

Research for Thrust Distribution Method of DACS for Response to Pintle Actuating Failure (DACS 추진기관의 핀틀 구동장치 고장을 허용하는 추력 분배기법 연구)

  • Ki, Taeseok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.61-70
    • /
    • 2017
  • Robust thrust distribution method of solid DACS is researched. For the case of the system which has higher number of actuation nozzles than the degree of freedom of thrust to be controlled, the robust thrust allocation law which accommodate the abnormal operation is suggested. Assuming the situation that some nozzles are uncontrollable, the error between nozzle throat area command and response can be calculated. The error is used for realtime reshaping of weighting matrix. From the weighting effect, the nozzle which operated abnormally has low responsibility for the command then, the thrust error is reduced. The suggested algorithm is verified by the simulation of abnormal operation condition of DCS and ACS nozzle respectively.

Concept Analysis of Cardiac Arrest: Identifying the Critical Attributes and Empirical Indicators (심정지(Cardiac Arrest)에 대한 개념분석: 개념적 속성 및 경험적 지표의 규명)

  • Lee, Kang Im;Oh, Hyun Soo
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.5
    • /
    • pp.573-583
    • /
    • 2014
  • Purpose: Cardiac arrest has multiple characteristics that need to be approached as an integrated method according to the various changes in the body system. This study was performed to develop a useful guideline for early detection of cardiac arrest by revealing the attributes of cardiac arrest through a concept analysis. Methods: This study was conducted according to the Walker and Avant's concept analysis method. Systematic literature review and in-depth interview with nurses who experienced cardiac arrest situation were conducted. Based on the literature reviews and in-depth interviews with nurses, the attributes and the empirical referents of the concept of cardiac arrest were elicited. Results: The definable attributes of cardiac arrest were 1) loss of consciousness, 2) abnormal respiratory condition, 3) abnormal cardiovascular signs. Cardiac arrest was found to occur by several antecedents such as cardiac problem, non-cardiac problem, or general problem, whereas ischemia and re-perfusion injury, which can lead to multiple organ failure and death, were derived as consequences. Conclusion: In this study, the concept analysis eliciting attributes and empirical referents is found to be useful as a guideline for understanding and managing cardiac arrest. Based on these findings, clinical providers are expected to make a precise and rapid decision on cardiac arrest and respond quickly, which may increase survival rate of the patients underwent the arrest event.

Acoustic screening test for laryngeal cancer (음성을 이용한 후두암의 집단선별검사)

  • 박헌수
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.2
    • /
    • pp.161-167
    • /
    • 2001
  • Background and Objectives: Total laryngectomy is often required for advanced cases. But this operation induced the many inconvenience of basic daily life. Early diagnosis of laryngeal cancer is very important to prevent from this disastrous condition. In this point of view, mass screening test for early detection of laryngeal cancer is necessary. Screening test using voice has many advantages such as simple, less interventional. Voice collection by Automatic Response System(ARS) is comfortable and easy to got acoustic sample. Thus author tried to got the acoustic parameters which can differentiate normal, benign. and malignant laryngeal diseases and also checked the availability of parameters on neural network system. Materials and Methods: Author has evaluated the voice from 17 laryngeal cancer patients and 45 benign laryngeal disease patients who visited at Department of Otolaryngology, Pusan National University Hospital from May 1998 to April 2001, and 15 normal control. Author chose the sir Parameters (Jitt. vFo, Shim, vAm, NHR, SPI) that was thought to be related with voice collected by ARS among thirty-three parameters analysed by a Multi-Dimensional Voice Program (MDVP). Two-step neural network was used for the availability of six parameters. Results: The detection rate of normal voice by ARS voice analysis is 78.5% and detection rate of abnormal voice was 97.1 o/o. Among abnormal voice, the detection rate of benign laryngeal diseases and laryngeal cancers were 82.4 o/o, 70.6% respectively. Conclusion: Author concluded that six parameters and Matlab based neural network software may be effective in development of acoustic screening system for laryngeal cancer and further study should be necessary for development of new acoustic parameters.

  • PDF

Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit (부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계)

  • Byun Jei-Young;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF