• Title/Summary/Keyword: Abnormal condition

Search Result 713, Processing Time 0.026 seconds

Power Characteristic Analysis of Assumed Short Circuit Instance of Electric Ship Propulsion System (선박용 전기추진시스템의 단락상정사례의 전력특성 분석)

  • Jeon, Won;Wang, Yong-Peel;Jeong, Jong-Hwa;Lyu, Sung-Kak;Jung, Sang-Yong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.323-329
    • /
    • 2008
  • This paper deals with modeling and characteristic analysis of a large-powered electric ship propulsion system. Particularly, system modeling in accordance with the required shipping performance, building-up the equivalent circuit and the power analysis based on load flow have been performed. In addition, abnormal operating condition of short-circuit network is considered for investigating the safety of system components under the over-load condition. Furthermore, protective device like circuit breaker has been specified in order to make the entire system operate normally in case of short-circuit emergency.

"Misery Collaterals" as Poor Angiographic Findings - Definition, Classification, and Practical Application -

  • Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.3
    • /
    • pp.159-163
    • /
    • 2006
  • Objective : Unique Internal carotid artery angiographic findings have been found especially in very poor grade aneurysmal subarachnoid hemorrhage[SAH] patients before and during the endovascular coiling. The author investigates their patterns and classifies them into lour subtypes. Methods : Among Hunt&Hess grade IV, V SAH patients, the author could gather eight patients who showed abnormal intracranial circulation in cerebral catheter-based angiography. Results : The author introduces new term 'misery collaterals' first and has classified them into four types with the case illustrations. Type 1 is the worst condition defined as almost no intracranial circulation. Type 2 is the condition of little intracranial circulation with contrast filling just only at vessels of brain base, type 3 is of no or little cortical circulation with contrast filling at bilateral large vessels of brain base through circle of Willis channel and type 4 is of visible bilateral cortical circulation but delayed intracranial circulation time. The prognosis of these eight patients showed misery collaterals were disappointed. Conclusion : These finding can be used as the supportive information in deciding a management plan in poor grade SAH patients.

Inspection of General Use Electric Installation Using Leakage Current Measuring (누설전류측정을 이용한 일반용전기설비의 점검)

  • Lim, Young-Bae;Jung, Jong-Wook;Jung, Jin-Soo;Bae, Seok-Myung;Cho, Seong-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.63-65
    • /
    • 2006
  • A electrical fault is defined as any abnormal condition caused by a reduction in the insulation strength. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value could not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed. The result focuses on to detect them in a cost efficient way.

  • PDF

Analysis of the Ability of Recognize Objects for Smart Sensor According to Frequency Changing (주파수 변화에 따른 지적센서의 대상물 인식능력 분석)

  • 황성연;홍동표;강희용;박준홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.23-26
    • /
    • 2000
  • This paper descrtbcs our prlmary study for a new mncthod of recogninng materials. which is need for precision work system. This IS a study of dynarnlc characteristics of sensor. new melhod ($R_{SAI}$) has thc sensing ability of distinguishing materials. Experiment and annlysis are executed for proper dynamic scnslng condition. First. we developed advanced smart sensor Second, we develop new methods that have a sensing ability of distinguish matarialsAccording to frequency changing. mtluence of smart sensor are evaluated through new recognition Index ($R_{SAI}$) that ratioof sensing ability index. Disungush of object is cxucuted wllh RsA, method relalivcly according to liequency changing. Wecan use the RsAl for finding materids. Applfciltionr of thls method are linding abnormal condition of obicct (automanufacturing).keling ofobject (medlcal product). tobolics, safety diagnosis of structure, etc

  • PDF

Tortuous Internal Carotid Artery Presenting as an Oropharyngeal Mass : A Case Report (구인두 종괴로 오인된 내경동맥 사행 1예)

  • Kim, Il-Kang;Yum, Dong-Jin;Kang, Jae-Ho;Park, Sung-Ho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.2
    • /
    • pp.178-180
    • /
    • 2007
  • Tortuosity of the internal carotid artery is not a rare condition. A 68-year-old woman presented with a 3 years' history of a pulsatile tinnitus and throat abnormal sensation. On physical examination, a soft pulsatile mass on the left posterior oropharyngeal wall was noted. By neck CT and neck MRI the tortuous internal carotd artery was visualized. Otolaryngologists should recognize this anomaly and the patient should be made aware of their condition, because it may cause a fatal or near-fatal hemorrhage during surgical procedures in the pharynx, especially tonsillectomy and adenoidectomy and drainage of peritonsillar abscess. We report a case of a left internal carotid artery tortuosity as an oropharyngeal mass.

Development of Diagnostic Expert System for Rotating Machinery with Journal Bearing (저어널 베어링으로 지지된 회전축의 이상상태 진단을 위한 진단전문가 시스템의 개발)

  • 유송민;김영진;박상신
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.244-250
    • /
    • 2001
  • A rotating axis diagnostic system supported with journal bearing has been established that has been widely used in the industry. In order to measure the most sensitive signals that would be generated in the abnormal operation, sensors which measure AE(acoustic emission), gap and acceleration have been attached at the various location on the experimental apparatus. Data were obtained in the steady state operational condition of the system which was verified through the empirical measurement. Notable discrepancies were observed in RMS acceleration signal which could be utilized to predict the undesirable operational condition of the system.

Effects of AlN Ratio on Microstructure of AlN Films Grown by PAMBE (PAMBE를 이용하여 성장된 AlN 박막의 미세구조에 미치는 Al/N 비율 영향)

  • 홍성의;한기평;백문철;조경익;윤순길
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.12
    • /
    • pp.972-978
    • /
    • 2001
  • Some effects of Al/N ratio on microstructure of AlN films grown on Si(111) substrates by PAMBE were investigated. Al/N ratio was controlled by rf power of N$_2$ plasma source system. Al excess or N excess conditions were obtained below or above 350 W rf power, respectively. Surface roughness and morphology of AlN film grown at Al/N=1.0 showed the best result. Under Al excess condition, it was suggested that excess Al atoms which did not contribute to the growth of AlN film prevent the normal crystal growth and make abnormal growth of some columns. However, under N excess condition, it was explained that some of the excess active N source turned into gas state and then desorbed out from substrate.

  • PDF

Study on the Real-Time Leak Monitoring Technique for Power Plant Valves (발전용 밸브누설 실시간 감시기술 연구)

  • Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Study on Evaluation of the Leak Rate for Steam Valve in Power Plant (발전용 증기밸브 누설량 평가에 관한 연구)

  • Lee, S.G.;Park, J.H.;Yoo, G.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A study on the realization of color printed material check using Error Back-Propagation rule (오류 역전파법으로구현한 컬러 인쇄물 검사에 관한 연구)

  • 한희석;이규영
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.560-567
    • /
    • 1998
  • This paper concerned about a imputed color printed material image in camera to decrease noise and distortion by processing median filtering with input image to identical condition. Also this paper proposed the way of compares a normal printed material with an abnormal printed material color tone with trained a learning of the error back-propagation to block classification by extracting five place from identical block(3${\times}$3) of color printed material R, G, B value. As a representative algorithm of multi-layer perceptron the error Back-propagation technique used to solve complex problems. However, the Error Back-propagation is algorithm which basically used a gradient descent method which can be converged to local minimum and the Back Propagation train include problems, and that may converge in a local minimum rather than get a global minimum. The network structure appropriate for a given problem. In this paper, a good result is obtained by improve initial condition and adjust th number of hidden layer to solve the problem of real time process, learning and train.

  • PDF