• 제목/요약/키워드: Aberration correction

검색결과 48건 처리시간 0.017초

비점수차 (Astigmatism)가 제거된 안경렌즈 설계 (A Design of Eye-glasses on the Correct Aberration of Astigmatism)

  • 임현선;지택상;박상영
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.121-128
    • /
    • 1998
  • 본 연구에서는 Gullstrand eye model을 이용하여 눈의 광학적인 성능을 조사하였고, 비점수차를 보정한 안경렌즈를 설계하여, 설계한 렌즈와 눈과 합성된 광학계의 성능을 조사하였다. 본 연구는 비 정시안 교정용 안경 렌즈를 제작할 때 참고 자료로 활용 할 수 있다.

  • PDF

하트만 방법에 의한 광학면의 기상측정 (On-Machine Measurement of an Optical Surface by Hartmann Test)

  • 김용관;오창진;이응석;김옥현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.474-480
    • /
    • 2002
  • Aspheric optical lenses and mirrors are widely used in recent. It is more difficult to manufacture and measure the aspherical optics compared to conventional spherical ones. The interferometric optical test is common for the measurement of spherical optical surface. But the application of the interferometry to the measurement of aspheric surface is difficult because it needs a precise null corrector and very careful environmental conditions such as keeping constant temperature, humidity, atmospheric pressure and vibrations. To enhance productivity of optics manufacturing on-machine measurement and correction has been developed in this study. For practical applications, robustness of the measurement method to environments is more important. For the purpose an optical OMM(On-Machine Measurement) system has been developed using Shack-Hartmann test which has robustness to the environment. The wavefront has been reconstructed from the measured data using the primary aberration polynomial function by least square fitting. The measured result of the developed only system gives the maximum deviation only in 200 nm from the result measured by a commercial Fizeau interferometer Wyko 6000.

  • PDF

비축시야 2반사광학계에서 조리개의 편심을 이용한 수차보정 (Aberration Correction of an Off-axial-field Two-mirror System Using a Decentered Aperture)

  • 이종웅
    • 한국광학회지
    • /
    • 제31권1호
    • /
    • pp.20-25
    • /
    • 2020
  • 넓은 시야를 가지는 2반사광학계를 설계하기 위하여서는 제2거울에 의한 광선의 차폐와 시야 가림이 없도록 비축시야를 사용하여야 한다. 그러나 이러한 2반사경계에서는 설계변수가 적어 비축수차를 충분하게 보정할 수 없었다. 이 연구에서는 조리개를 편심시켜 보다 성능이 개선된 비축시야 2반사광학계를 설계하였다.

Risley Prisms Scanning Optical Imaging System Using Liquid Crystal Spatial Light Modulator

  • Song, Dalin;Chang, Jun;Zhao, Yifei;Zhao, Qing
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.215-219
    • /
    • 2019
  • Chromatic aberrations induced by Risley prisms made of a single material can be substantially compensated using a liquid crystal spatial light modulator while still keeping the prism pairs compact, simple and lightweight. A ${\pm}10^{\circ}$ optical scanning imaging system with ${\pm}2^{\circ}$instantaneous field based on LC-SLM correction is designed as an example. The ultimate simulation results show that this kind of scheme is an effective way of improving imaging performance dynamically across the full field of scanning.

TEM sample preparation of microsized LiMn2O4 powder using an ion slicer

  • Jung Sik Park;Yoon‑Jung Kang;Sun Eui Choi;Yong Nam Jo
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.19.1-19.7
    • /
    • 2021
  • The main purpose of this paper is the preparation of transmission electron microscopy (TEM) samples from the microsized powders of lithium-ion secondary batteries. To avoid artefacts during TEM sample preparation, the use of ion slicer milling for thinning and maintaining the intrinsic structure is described. Argon-ion milling techniques have been widely examined to make optimal specimens, thereby making TEM analysis more reliable. In the past few years, the correction of spherical aberration (Cs) in scanning transmission electron microscopy (STEM) has been developing rapidly, which results in direct observation at an atomic level resolution not only at a high acceleration voltage but also at a deaccelerated voltage. In particular, low-kV application has markedly increased, which requires a sufficiently transparent specimen without structural distortion during the sample preparation process. In this study, sample preparation for high-resolution STEM observation is accomplished, and investigations on the crystal integrity are carried out by Cs-corrected STEM.

근시에서의 라섹과 TransPRK라섹 수술 후 고위수차 비교 (After Lasek Surgeried and TransPRK Surgeried for Myopia, Comparison of High-order Aberrations)

  • 박준성
    • 한국임상보건과학회지
    • /
    • 제3권2호
    • /
    • pp.372-377
    • /
    • 2015
  • Purpose: The aim of this study is to compare total high order aberrations between surgery which uses TransPRK and general laser assisted sub-epithelial keratomileusis. Methods: The patients who had general laser assisted sub-epithelial and TransPRK laser assisted sub-epithelial by visiting ophthalmic clinic in Ulsan from January 2014 to August 2014 was researched. Results: When comparing total high order aberrations before and after operation, it was found that total high order aberration in general laser assisted sub-epithelial group increased to $0.222{\pm}0.078{\mu}m$ from $0.074{\pm}0.019{\mu}m$ while that in TransPRK assisted sub-epithelial group increased to $0.179{\pm}0.045{\mu}m$ from $0.076{\pm}0.032{\mu}m$. When comparing the increment in total high order aberrations between two groups after surgery, it was found that the increments of TransPRK assisted sub-epithelial group were statistically smaller than that of general laser assisted sub-epithelial group (p<0.05). Conclusions: This study made a comparative analysis of total high order aberrations between general laser assisted sub-epithelial and TransPRK assisted sub-epithelial which was introduced recently and the result showed a significant difference. The findings of this study suggest that TransPRK assisted sub-epithelial can be used widely in simply improving eye sight and quality of vision by reducing an increase in high order aberration caused by orthokeratology surgery. It is expected that TransPRK assisted sub-epithelial will be helpful for improving the understanding quality of eye sight which occurs by several methods of vision correction surgery.

비열화 소재 구성 방법을 이용한 중적외선 카메라용 확장형 10배 줌 렌즈 설계 (Design of a 10× Zoom Lens with an Expander for an MWIR Camera Using Athermal Material Composition Method)

  • 류태식;박성찬
    • 한국광학회지
    • /
    • 제33권6호
    • /
    • pp.287-294
    • /
    • 2022
  • 본 연구에서는 중적외선용 줌 광학계를 비열화에 유리한 소재 조합으로 구성하기 위해 비열화 유리 지도를 이용한 반복적인 설계 방법을 제시한다. 일반적으로 중적외선용 유리 소재는 가시광선용 소재에 비해 온도변화에 매우 민감하다. 또한 줌 광학계는 이동군이 존재하여 온도 변화에 따른 성능 보상이 어느 정도 가능하지만, 광학 렌즈에 적절한 소재가 배치되지 않으면 온도에 따른 이동군의 보상량이 크게 발생하여 비열화 설계 시 어려움이 발생한다. 이러한 문제점을 해결하기 위해 비열화 유리 지도상에서 수차 보정을 위한 값을 분석하여 비열화에 유리한 소재로 중적외선용 줌 광학계를 구성하고, 초점거리 2배 확장기를 부착하여도 온도 변화에 안정적인 확장형 줌 광학계를 설계하였다.

조리개와 제 2거울이 횡이동된 비축시야 2반사 광학계 설계 (Optical Design of an Off-Axial-Field Two-Mirror System with a Displaced Stop and a Secondary Mirror)

  • 남지우;이종웅
    • 한국광학회지
    • /
    • 제31권6호
    • /
    • pp.304-313
    • /
    • 2020
  • 조리개가 제 2거울에 있는 inverse Cassegrain 광학계에서 비축시야를 사용하면, 이 2반사경계는 넓은 시야를 가지는 대물광학계로 사용할 수 있다. 하지만 이 전통적인 회전대칭 구조의 반사경계는 설계변수의 수가 너무 적기 때문에 수차보정에 한계가 있다. 이 연구에서는 조리개와 제 2거울을 별도로 횡이동시켜 성능을 개선한 새로운 2반사 광학계를 설계하였다. 새로운 설계변수를 사용하여 5차 코마와 비점수차에 대한 보정이 개선되었으며, 시야 전체에서 보다 좋은 수차균형을 얻을 수 있었다. 새로 설계된 비축시야 2반사경계는 회전대칭 구조의 통상적인 2반사경계와 비교하여 spot의 크기가 1/2 수준으로 줄어들었으며, 개선의 효과가 시야 전체에 고르게 나타나고 있다.

테이핑 요법으로 호전된 요통환자의 요추전만도 변화 1례 (Change of Lumbar Lordotic angle by Taping Therapy on Low Back Pain Patient with Lumbar Hyperlordosis ; A Case Report)

  • 윤유석;이종수;문상현
    • 대한추나의학회지
    • /
    • 제4권1호
    • /
    • pp.157-165
    • /
    • 2003
  • Low back pain (LBP) is a significant in today's society, with lifetime include factors associated with LBP ar reporter. Among the causes, aberration of posture may play a role in the development of LBP. Many investigators have assessed the curvature of spine in standing posture. But LBP is associated with Lumber Hyperlordosis of Hyperlordosis is controversial Subjects: In conservative treatment(acupuncture, herb med, manipulation & TENS. exercise, potural correction) for a 40 years old woman who had low back pain(V AS) be caused by decrease lumbar lordotic angie. Objectives: The object is change of lumbar lordotic angle of a 40 years old woman who had low back pain with Lumbar hyperlordosis, In conservative treatment. Method: In conservative treatment, We added taping therapy(mechanical correction taping of Kinesio Taping) about Lumbar Lordosis. Conclusion: We experienced a 40 years old woman who had love pack pain with Lumbar hyperlordosis. In conservative treatment, Her pain was Improved by additional taping therapy In company with decrease of Lumbar Lordosis. 1. abnormal spinal curvature, specially lumbar hyperlordosis act on induction & perpetuation agent for low back pain 2. In a patient had low back pain with lumbar hyperlordosis, change of lumbar lordotic angle is of utility value for the effect of treatment and assessment of prognosis. 3. pain control is more relative with change of lumbosacral angle than lumbar lordotic angle, in patient had low back pain with lumbar hyperlordosis. 4. mechanical taping therapy with elastic adhesive tape is effective for patient had low back pain with lumbar hyperlordosis

  • PDF

적외선 및 가시광선 결상용 3반사망원경계의 설계 (Optical design of three-mirror telescope system for infra-red and visible imaging)

  • 이종웅;홍경희;권우근
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.183-190
    • /
    • 1996
  • 적외선, 가시광선 겸용의 3반사망원경계를 설계하기 위하여 형상설계법 및 3차수차의 보정방법이 연구되었다. 적외선용의 광학계는 3반사경계만으로 구성되었으며 원추곡면화를 통하여 구면수차, 코마, 비점수차를 보정하였다. 가시광선용의 광학계는 적외선용의 3반사경계의 상면앞에 보정렌즈를 추가하여 상면만곡을 보정하였다. 설계된 3반사망원경계는 파장 10.mu.m에서는 시계 2.4.deg. 내에서 회절한계의 결상성능을 가지고 있다. 가싣광선대역의 단파장에 대한 rms spot size는 3.deg. 시계내에서 25.mu.m이하이며, CCD의 사용에 적합하도록 flat field 조건을 만족하고 있다.

  • PDF