• Title/Summary/Keyword: Abdominal Dimension Measurement

Search Result 10, Processing Time 0.033 seconds

Accuracy Evaluation of Tidal Volume Measured on the Abdomen (복부에서 측정하는 일회 호흡용적의 정확도 평가)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1298-1303
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Wearable wireless respiratory monitoring system (의복착용형 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Abdominal-Deformation Measurement for a Shape-Flexible Mannequin Using the 3D Digital Image Correlation

  • Liu, Huan;Hao, Kuangrong;Ding, Yongsheng
    • Journal of Computing Science and Engineering
    • /
    • v.11 no.3
    • /
    • pp.79-91
    • /
    • 2017
  • In this paper, the abdominal-deformation measurement scheme is conducted on a shape-flexible mannequin using the DIC technique in a stereo-vision system. Firstly, during the integer-pixel displacement search, a novel fractal dimension based on an adaptive-ellipse subset area is developed to track an integer pixel between the reference and deformed images. Secondly, at the subpixel registration, a new mutual-learning adaptive particle swarm optimization (MLADPSO) algorithm is employed to locate the subpixel precisely. Dynamic adjustments of the particle flight velocities that are according to the deformation extent of each interest point are utilized for enhancing the accuracy of the subpixel registration. A test is performed on the abdominal-deformation measurement of the shape-flexible mannequin. The experiment results indicate that under the guarantee of its measurement accuracy without the cause of any loss, the time-consumption of the proposed scheme is significantly more efficient than that of the conventional method, particularly in the case of a large number of interest points.

Zigbee Based Wireless Respiration Monitor System (지그비 통신 기반의 근거리 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.142-147
    • /
    • 2008
  • Abdominal circumference changes due to breathing by the respiratory muscle activity such as diaphragm, which would partially represent the lung volume variation. The present study introduced conductive rubber molded in a cord shape incorporated with a patient's pants. The conductive rubber cord operated as a displacement transducer to measure the lung or abdominal volume changes. Signal extraction circuitry was developed to obtain the volume and its derivative(or the flow) signals followed by wireless transmission based on the Zigbee communication protocol in a size of $65mm{\times}105mm$ easily put in pocket. Breathing frequency was accurately evaluated and breath pattern analysis seemed feasible, since respiratory behaviours such as maximal inspiration and cough were well identified. Remote wireless receiver module also enabled to monitor both volume and flow signals during resting breathing on a PC terminal.

Development of an evaluation tool for the quality of nursing care in abdominal surgery patients (복부수술 환자간호의 질평가 도구 개발)

  • Lee, Byoung-Sook
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.1
    • /
    • pp.107-127
    • /
    • 1998
  • The purpose of this study was to develop an evaluation tool for the quality of nursing care in abdominal surgery patient. The target subjects of the tool were adult patients having abdominal surgery under general anesthesia. Process-outcome framework was selected for the development of the tool in this study. The results were as follows. 1. Nine standards. 40 criteria and 88 indicators were developed. A standard was summary statement of the ideal level of excellencein a dimension of quality of nursing care. which could be evaluated by criteria. Several criteria indicated a specific standard and each criterion could be measured by observable and measurable indicators. 2. The standards were divided into two dimensions. One was process dimension which contained four standards(23 criteria), the other was outcome dimension which contatined five standards(17 criteria). 3. Average CVI was .985 at 9 standards. .947 at 40 criteria. and .987 at 88 indicators. 4. The evaluation tool for the quality of nursing care in abdminal surgery patients was a criterion-referenced tool. And data collection methods of the tool were investigation of patient's record and interview( or questionnaire) with the patients. 5. Interrater reliabilities of the tool were ; r= .7572 (agreement between two raters), and pI=.8487 (intraclass correlation between five raters who rated the 84 patients). 6. Internal consistency reliability ${\alpha}$ was .6194, which was obtained from 32 criteria. Eight criteria were missed in the analyzing process because of data omission. 7. Scores of the process and the outcome dimensions showed significant. but low correlation(r= .3759, p < .001). 8. There were significant differences in total scores between the hospitals and the departments of surgery(F = 15.233. p .0001). There was also significant interaction effect between hospitals and departments to total score(F = 8.396. p = .0001). Construct validity of the toool was verified by the known-group method. these kinds of difference were expected by the nursing experts participated in the study. From these results, more specific patient classification is suggested for the development of evaluation tool of the quallity of nursing care. And indicators to be used for objective measurement for the quality of nursing care must be developed.

  • PDF

A Study on Latitudinal Body form of Pregnant Women (임부체형(姙婦體型)의 횡단적(橫斷的) 연구(硏究))

  • Na, Mi Hyang;Park, Jeong Mi;Lee, Yeun Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.177-196
    • /
    • 1993
  • By cluster sampling measurements, passing months of pregnancy according to changes of pregnant women body forms. On the basis of the above mentioned data, sizes of pregnant women clothes were decided. The results are as follows. 1. By cluster sampling measurements, sixty-nine items of apparel were obtained during the three different periods of pregnancy. They included the mean and standard deviation of body form measurement and the minimum and maximum values (Chart 3-4). The results of these surveys made it possible to notice the changes of pregnant womens' physical characteristics, i. e., the increased physical proportions: frontal waist area, umbilicus width, abdominal girth, crotch length, the length of the nipple, and body weight and the decreased proportions: omphalos height, perineum dimension. There was little change in the rear parts of the body. 2. The analized results of principle factors for body form measurements by cluster measurements produced seven major factors for which the proper values were over 1.0. They were: form factor, pregnancy factor, posture factor, breast formation factor, rear body formation factor, and nipple to nipple breadth. 3. In deciding garment sizes of pregnant women, four different sizes were established; small, medium, large, and extra-large according to the third, fifth, eighth, and tenth month of pregnancy. The measurement value of each item was produced by estimate.

  • PDF

Correlation Analysis Between 3D Kidneys Measurements and Abdominal Obesity Level in Computed Tomography (전산화단층영상에서 콩팥 3차원 영상 계측치와 복부 비만도 간의 상관관계 분석)

  • Ji-Yeong Kim;Youl-Hun Seoung
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.315-325
    • /
    • 2023
  • The purpose of this study was to predict abdominal obesity with 3-Dimensional computed tomography (3D CT) measurements of kidneys by analyzing the correlation between kidney sizes and abdominal obesity level. The subjects were 178 healthy adults without underlying diseases who had a comprehensive health examination at the Health Medical Center of Jesus Hospital in Jeonju. Abdominal obesity was measured by CT cross-sectional image at the level of the umbilicus and divided into visceral fat area, subcutaneous fat area, visceral fat/total fat ratio. The average comparison of kidney sizes classified according to abdominal obesity were performed through one-way analysis of variance (ANOVA) and Scheffe test. Pearson correlation analysis was performed to correlate all measurement values. The results of kidney size ANOVA analysis according to abdominal obesity were as follows. The means of kidney measurements according to visceral fat classification were significantly different in all kidney measurements (p<0.05). And in case of subcutaneous fat classification, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in the right kidney width (p<0.05). In case of visceral fat area/total fat area ratio, the means of kidney measurements by 3D CT of the severe obesity group were significantly different in both kidneys width (p<0.05). Pearson correlation between kidneys measurements and CT abdominal obesity showed that visceral fat area had the highest correlation with the left kidney width measured by 3D CT (r=0.467) and subcutaneous fat area had correlation with the right kidney width measured by 3D CT (r=0.249). The visceral fat area/total fat area ratio had correlation with the left kidney width measured by 3D CT (r=0.291).

Comparative Assessment of Fractal Analysis and Histogram in Canine Abdominal Ultrasonographic Images (개 복부초음파영상의 프랙탈 분석과 히스토그램 분석의 비교평가)

  • Choi, Ho-Jung;Lee, Young-Won;Jung, In-Jo;Wang, Ji-Hwan;Lee, Kyung-Woo;Yeon, Seong-Chan;Lee, Hyo-Jong;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.568-572
    • /
    • 2007
  • This study was carried out to show at the fractal analysis complements the practical disadvantage of gray level histogram which is designed to measure the quantitative classification of echo patterns in ultrasonographic image of parenchymal organs such as spleen and kidney and it is a practical method of measurement for quantitative classification. By using ultrasonographs, kidney and spleen of 21 healthy Beagles were fixed under different gain settings to be scanned for echo patterns and results were analyzed with body gray level histogram and fractal analysis. Then it was compared based on the statistical data obtained. Although there was a proportionate increase in histogram along with gain settings, there were consistencies in the fractal dimension. In terms of quantitative analysis in ultrasonographic images, fractal analysis is concluded to complement the practical disadvantage of gray level histogram.

A Study on Body from Variation of Adult Males in the Twenties for Closing Construction (의복구성을 위한 20대 남성의 체형변화 연구)

  • Yoo Shin Jung;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.15 no.4 s.40
    • /
    • pp.393-403
    • /
    • 1991
  • The purpose of this study were to explain the difference in body dimensions and body shape between the early in the twenties and the late in the twenties and to get information clothing construction. Subject were 483 Korean males, which were extracted from men's physique investigation on June to August in 1989, consisted of 149 aged $19\~24$ and $25\~29$. T-test and factor analysis were applied to 52 measurement items and 58 indices. The Result of the study were as follow; 1. As regards $19\~24$ aged group, they were taller their waistband level was higher than the late in the twenties. Upper arm and thigh were thick in comparison with trunk. As the difference between shoulder and waist in dimension was great, they showed reverse triangular silhouette. As regard $25\~29$ aged group, their body from variation between individual was greater than that of 19~24 aged group and they were obese on mainly waist and abdominal parts. For that reason, waist band level became low and their shoulder and hip looked slim relatively that reason, waist band level became low and their shoulder and hip look slim relatively to bust and waist parts. 2. Between $19\~24$ aged and $25\~29$ aged groups, as each had charicteristic body from, there was the difference in factor structure. 3. The change of men's body from with age in their twenties was obeseness on the whole body but the increasing rate of upper arm and thigh girth was less than that of trunk girth.

  • PDF

Analysis of Female Body Types in Their 20s and 30s for Modeling Korean Standard Avatar (한국인 표준 아바타 모델링을 위한 20-30대 여성 체형 분석)

  • Eun-Hee Hong;Ji-Won Yoon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.24 no.4
    • /
    • pp.57-72
    • /
    • 2022
  • This study categorized and analyzed the body types of adult women in their 20s and 30s using 3D human measurement data from the 8th Size Korea, and intended to construct body shape and dimension data necessary for modeling Korean standard avatars. Data analysis considered data from 1302 adult women in their 20s and 30s, and a total of 49 index values, drop values, and angle items were subjected to factor analysis and one-way ANOVA to categorize the body type, and Duncan test to post-verify significant differences by type. As a result of conducting factor analysis, 13 factors were extracted and were categorized into 4 body types. Type 1 is short in the upper torso, long in the lower torso, long in the arms and legs, and has a upright body shape and sagging shoulder. Type 2 is short in the torso, arms and legs, and has large torso flexion and lower body circumference. Type 3 has abdominal obesity with small torso flexion and lower body circumference. Type 4 is a small body bending forward type. For the distribution of body types by age among those in their 20s and 30s, the highest appearance rate was Type 1 and was therefore selected as the represntative body type. The body type information of this study will be used as basic data for developing standard avatars.