• Title/Summary/Keyword: ATP detection

Search Result 49, Processing Time 0.02 seconds

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

Assembly of Gold Nanoparticles on Electrospun Polymer Nanofiber Film for SERS Applications

  • Wang, Li;Sun, Yujing;Wang, Jiku;Li, Zhuang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.30-34
    • /
    • 2014
  • We report a novel approach for fabricating active surface-enhanced Raman scattering (SERS) substrate for sensitive detection. This approach is based on the assembling of gold nanoparticles (AuNPs) onto the electrospun polycaprolactone (PCL) nanofiber film. The hydrophobic surface of PCL nanofiber film was pretreated using UV-inducing graft polymerization with acrylic acid. Afterwards this PCL nanofiber film was incubated with the AuNP solution to promote the assembly of AuNPs onto the PCL nanofibers and the formation of SERS active substrate. 4-aminothiophenol (4-ATP) molecule was used as a test probe for SERS experiments, indicating that the substrate has high sensitivity to SERS response. Our method has great advantage in term of environment-friendly synthesis, large-scale, high stability and good reproducibility. This highly active SERS substrate can be employed to detect the drug molecule, 2-thiouracil.

Internal Fault Classification in Transformer Windings using Combination of Discrete Wavelet-Transforms and Back-propagation Neural Networks

  • Ngaopitakkul Atthapol;Kunakorn Anantawat
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.3
    • /
    • pp.365-371
    • /
    • 2006
  • This paper presents an algorithm based on a combination of Discrete Wavelet Transforms and neural networks for detection and classification of internal faults in a two-winding three-phase transformer. Fault conditions of the transformer are simulated using ATP/EMTP in order to obtain current signals. The training process for the neural network and fault diagnosis decision are implemented using toolboxes on MATLAB/Simulink. Various cases and fault types based on Thailand electricity transmission and distribution systems are studied to verify the validity of the algorithm. It is found that the proposed method gives a satisfactory accuracy, and will be particularly useful in a development of a modern differential relay for a transformer protection scheme.

Visual Detection of Di-and Tri-phosphates in Aqueous Solution of Neutral pH

  • Han, Min-Su;Kim, Dong H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.8
    • /
    • pp.1151-1155
    • /
    • 2004
  • The chemosenssor that consists of [$Zn_2$(1,3-bis[bis(2-pyridylmethyl)aminomethyl]benzene)]$^{4+}$ (receptor) and pyrecatechol violet (signaling unit) detects with naked eyes di- and tri-phosphates conjugated to nucleosides or in free forms. The blue color of the aqueous solution (pH 7.0) of the sensor turns to yellow upon exposing to the analytes.

5-Aminolevulinic Acid Fluorescence in Detection of Peritoneal Metastases

  • Yonemura, Yutaka;Canbay, Emel;Ishibashi, Haruaki;Nishino, Eisei;Endou, Yoshio;Sako, Shouzou;Ogura, Shun-Ichirou
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2271-2275
    • /
    • 2016
  • Background: The value of 5-aminolevulinic acid (ALA) in fluorescence detection of peritoneal metastases and the underlying mechanisms were evaluated in patients with peritoneal surface malignancies. Materials and Methods: Oral 5-ALA was administered at a concentration of 20 mg/kg body weight with 50 ml of water 2 hours prior to surgery (n=115). The diagnostic value of 5-ALA based fluorescence production was evaluated following white light inspection during prior to cytoreductive surgery and hyperthermic intraperitoneal chemotherapy. Then, peptide transporter PEPT1 (ALA influx transporter) and ATP-binding cassette transporter ABCG2 (porphyrin efflux transporter) gene expression was determined with quantitative real time (qRT)-PCR and pathological diagnoses confirmed for all tissue samples. Results: The 5-ALA based photodynamic detection rate was 17% for appendiceal mucinous neoplasms, 54% for colorectal cancers, 33% for gastric cancers, 67% for diffuse malign peritoneal mesotheliomas, and 89% for epithelial ovarian cancer of peritoneal metastases. 5-ALA was detected in all cases of peritoneal metastases originating from cholangiocarcinomas whereas it was not able to detect any in granulosa cell and gastrointestinal stromal tumor cases. Furthermore, PEPT1 was overexpressed whereas ABCG2 expression was downregulated in tumors detected with fluorescence. Conclusions: 5-ALA provided 100% specificity and high sensitivity to detect peritoneal metastases in subgroups of patients with peritoneal surface mailgnancies. ALA influx transporter PEPT1 and porphyrin efflux transporter ABCG2 genes are important in tumor specific 5-ALA induced fluorescence in vivo. Further studies should clarify diagnostic utility of 5-ALA in peritoneal surface malignancies.

Comparative Genomic Analysis and Rapid Molecular Detection of Xanthomonas euvesicatoria Using Unique ATP-Dependent DNA Helicase recQ, hrpB1, and hrpB2 Genes Isolated from Physalis pubescens in China

  • Faisal Siddique;Yang Mingxiu;Xu Xiaofeng;Ni Zhe;Haseeb Younis;Peng Lili;Zhang Junhua
    • The Plant Pathology Journal
    • /
    • v.39 no.2
    • /
    • pp.191-206
    • /
    • 2023
  • Ground cherry (Physalis pubescens) is the most prominent species in the Solanaceae family due to its nutritional content, and prospective health advantages. It is grown all over the world, but notably in northern China. In 2019 firstly bacterial leaf spot (BLS) disease was identified on P. pubescens in China that caused by both BLS pathogens Xanthomonas euvesicatoria pv. euvesicatoria resulted in substantial monetary losses. Here, we compared whole genome sequences of X. euvesicatoria to other Xanthomonas species that caused BLS diseases for high similarities and dissimilarities in genomic sequences through average nucleotide identity (ANI) and BLAST comparison. Molecular techniques and phylogenetic trees were adopted to detect X. euvesicatoria on P. pubescens using recQ, hrpB1, and hrpB2 genes for efficient and precise identification. For rapid molecular detection of X. euvesicatoria, loop-mediated isothermal amplification, polymerase chain reaction (PCR), and real-time PCR techniques were used. Whole genome comparison results showed that the genome of X. euvesicatoria was more closely relative to X. perforans than X. vesicatoria, and X. gardneri with 98%, 84%, and 86% ANI, respectively. All infected leaves of P. pubescens found positive amplification, and negative controls did not show amplification. The findings of evolutionary history revealed that isolated strains XeC10RQ, XeH9RQ, XeA10RQ, and XeB10RQ that originated from China were closely relative and highly homologous to the X. euvesicatoria. This research provides information to researchers on genomic variation in BLS pathogens, and further molecular evolution and identification of X. euvesicatoria using the unique target recQ gene through advance molecular approaches.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화)

  • Kwon O-Sang;Kim Chul-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.7
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

Comparison of the Metabolic Syndrome Risk Factor Prevalence Forty and Fifty Something Women (40, 50대 여성 비만도와 연령 별 대사증후군 위험인자 비교)

  • Kim, Hee-Seung;Oh, Jeong-Ah
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.4
    • /
    • pp.453-458
    • /
    • 2007
  • Purpose: The purpose of this study was to compare metabolic syndrome (MS) risk factor prevalence by obesity and age in middle-aged women. Method: Two hundred and fifty-one subjects were recruited from the health promotion center of a tertiary care hospital in an urban city. MS was defined by the third report of the national cholesterol education program (NCEP) expert panel on detection, evaluation, and treatment of high blood cholesterol in adults(Adult Treatment Panel III)(ATP III), and obesity was determined by body mass $index(BMI){\geq}25kg/m^2$. Results: The mean blood pressure, fasting glucose, total cholesterol, and triglyceride were significantly higher in the obese group than in the non-obese group. The prevalence of MS, hypertension, and impaired fasting glucose were significantly higher in the obese group than in the non-obese group. In the forties, blood pressure was significantly higher in the obese group than in the non-obese group. In the fifties, body fat, systolic blood pressure, fasting glucose, total cholesterol, and triglyceride were significantly higher in the obese group than in the non-obese group. Conclusions: These results show that the nurse should focus on the obese fifty year old female patients for improvement of the MS risk factors.

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power trajectory in Complex plane (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 탁소전력의 궤적변화)

  • Kwon, O.S.;Kim, C.H.;Park, N.O.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.310-312
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load the oscillation can be severe and even increase largely and finally the out-of-step condition may occur During the power swing and out-of-step conditions, the a apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

  • PDF

Identification of Arcing Fault and Development of An Adaptive Reclosing Technique about Arcing Ground Fault (아크지락사고에 대한 사고 판별 및 적응 재폐로 기법)

  • Kim, H.H.;Choo, S.H.;Chae, M.S.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.354-356
    • /
    • 2006
  • This paper presents a new one-terminal numerical algorithm for fault location estimation and for faults recognition. The proposed algorithm are derived for the case of most frequent single-phase line to ground fault in the time domain. The arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent of transient. In this paper the algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm the Electro-Magnetic Transient Program(EMTP/ATP) is used.

  • PDF