• Title/Summary/Keyword: ATP Draw

Search Result 17, Processing Time 0.036 seconds

Simulation and Characteristic Analysis Using ATP Draw for Power System Equipments (ATP Draw를 이용한 전력계통 설비의 모의 및 특성분석)

  • Ha, Cha-Wung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1227-1229
    • /
    • 1999
  • The ATP Draw is a graphical mouse-driven preprocessor to ATP on the Windows Platform. User can build a graphical picture of the electric circuit by selecting components from menus. In this paper, ATP Draw is used to analyze power transformer transient characteristics and lightning overvoltage phenomenon in underground transmission cables. The results obtained by simulations will be used to identify the response of the digital protection algorithms in power system equipment

  • PDF

A Study on the GIL Modeling by ATP/Draw(EMTP) (ATP/Draw를 이용한 GIL 모델링 기법 연구)

  • Park, Hung-Sok;Jang, Tae-In;Kang, Ji-Won;Kim, Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.307-308
    • /
    • 2008
  • 345kV 4복도체 이상의 가공선로를 GIL로 지중화 대치하기 위한 검토사항 중의 하나로서 GIL-가공선로 연계시의 과전압 접지방식 순환전류 등의 특성을 검토할 필요가 있다. 이를 위해서는 GIL을 포함하는 승전계통을 EMTP로 모델링하여 실계통에 나타날 수 있는 다양한 현상 및 특성을 분석할 필요가 있으나, 현재 전력계통 과도현상을 모의 할 수 있는 ATP/Draw(EMTP) 상에는 GIL을 모델링하기 위한 명시된 모델이나 방법이 존재하지 않아 현상 분석에 어려움이 있다. 따라서, 이 논문은 가공선로 중간의 일부구간에 GIL이 존재할 경우에 있어서 ATP/Draw(EMTP)를 이용한 GIL 및 가공송전선의 혼합선로 모델링에 대한 내용을 다루며, 구체적으로 GIL에 대한 모델링 시 GIS 또는 Cable 모델을 이용한 모의방법을 비교분석하여 적합한 방법을 제안한다.

  • PDF

Modeling of Power Networks by ATP-Draw for Harmonics Propagation Study

  • Ali, Shehab Abdulwadood
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.283-290
    • /
    • 2013
  • This paper illustrates the possibilities of using the program ATP-Draw (Alternative Transient Program) for the modeling of power networks to study power quality problems with highly detailed analyses. The Program ATP-Draw is one of the most widespread and oldest programs. A unique characteristic of this program is its public domain and the existence of forums and study committees where new application cases and modification are presented and shared publicly. In this paper, to study the propagation of harmonics through a power network, a part of an industrial power network was modeled. The network contains different types of electric components, such as transformers, transmission lines, cables and loads, and there is a source of harmonics that injects $3^{rd}$, $5^{th}$, $7^{th}$, $9^{th}$ and $11^{th}$ harmonic currents into the network, causing a distortion of the wave form of the currents and voltages through the power network.

Analysis of Sheath Induced Voltage in Transmission Power Cable Connected with CCPU (방식층 보호장치의 설치에 따른 지중송전케이블 시스 유기전압 해석)

  • Lee, Jun-Sung;Lee, Jong-Beom;Kim ,Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • This paper describes the sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze the sheath induced voltage in the real cable system which was installed by 154㎸ CV cable in the case with and without CCPU. The sheath induced voltage will be also analyzed according to the change of grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results show whether the CCPU in necessary or not in underground transmission power cable system.

  • PDF

Improving Breakdown Voltage Characteristics of GDAs using Trigger Voltage

  • Lee, Sei-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.4
    • /
    • pp.646-652
    • /
    • 2010
  • This paper investigates a method to improve the breakdown voltage characteristics of a gas discharge arrester (GDA) for a surge suppressor. The middle electrode is inserted between two terminal electrodes. Voltage application to the electrode synchronized and amplified by the impulse voltage decreases spark overvoltage from 45% to 57.6%. The decrease is caused by higher voltage slope, as opposed to applied impulse voltage (by 5.5 to 6.2 times). In addition, the GDA model using ATP-Draw was used to analyze the operation characteristics of GDAs. The test and simulation results agree to within 2% when the trigger source was used.

A Study on Fault Location Using Wavelet in 154kV Transmission Power Cable (154kV 지중송전케이블에서 Wavelet을 이용한 Fault Location에 관한 연구)

  • Lee, Jun-Seong;Mun, Seong-Cheol;Lee, Jong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.12
    • /
    • pp.608-613
    • /
    • 2000
  • This paper describes a fault location technique using wavelets in underground transmission power cable system. Estimation of fault location is performed using data smapled at two ends underground system. In the case of 50% fault of total underground transmission line, fault location is calculated using sampled single-end data in underground transmission line. Traveling wave is utilized in capturing the travel time of the transients along the monitored lines between the relay and the fault point. This traveling time information is provided by the wavelet. Simulation was performed using EMTP, ATP Draw and MATLAB. The results of fault location shown in this paper will be evaluated as an effective suggestion for fault location in real underground transmission line.

  • PDF

Operational Method of Superconducting Fault Current Limiter with Reduction Function of Asymmetric Fault Current (비대칭 고장전류 저감 기능을 갖는 초전도 한류기 동작 방안)

  • Kim, Chang-Hwan;Seo, Hun-Chul;Kim, Kyu-Ho;Kim, Chul-Hwan;Rhee, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.56-62
    • /
    • 2014
  • When fault currents contain decaying DC offset, the peak value of the fault current in the first cycle of the fault period is higher than the fault current during the steady-state period. To reduce the asymmetric fault current, this paper proposes an operation scheme using the series connection of two hybrid type Superconducting Fault Current Limiters (SFCLs) : an auxiliary SFCL and a main SFCL. The proposed method calculates the fault angle by comparing the zero-crossing time with fault detection time. According to the fault angle calculated, an auxiliary SFCL operates to reduce an asymmetric fault current during half a cycle after fault occurrence. After this process, the fault current is limited by a main SFCL. To confirm the usefulness of the proposed method, case studies using Electro-Magnetic Transients Program (EMTP)/Alternative Transient Program (ATP) Draw are perfomed.

Transient Phenomena Analysis of HVDC Submarine Cable (HVDC 해저케이블의 과도현상 해석)

  • Jang, Hwa-Youn;Jeong, Seok-San;An, Chun-Yong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.490-491
    • /
    • 2011
  • This paper describes the EMTP/ATP Draw modeling HVDC submarine cable. HVDC submarine cables consist of conductor, lead sheath and amore. It is different from general cable which is composed with just conductor and aluminium sheath. Therefore, the transient characteristics are totally different between HVDC submarin cable and general cable. However, the study on HVDC cable modeling and Transient are insufficient. In this paper, characteristic and effectiveness of HVDC Submarine Cable through Transient analysis. Therefore it is evaluated that the application of HVDC Submarine cable at the field should be considered cautiously when more detailed transient analysis, another electrical testes and economic evaluations are implemented.

  • PDF

Assessment of Lightning Arrester Location in Combined Transmission Line Connected whth Overhead Line and Underground Cable (가공송전선로와 지중송전선로가 연계된 혼합송전선로에서 피뢰기 적정위치 검토 및 평가)

  • Ha, Che-Wung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.443-445
    • /
    • 2000
  • This paper describes the assessment of proper location of lightning arrester in combined transmission line which is connected with overhead line and underground cable. The modeling for simulation is established using the actual system in ATP Draw and EMTP. Simulation is carried out to find out the best point to install the arrester in given the model system. And also voltage and current is analyzed on cable covering protection unit(CCPU). The simulation result demonstrated the best location of arrester in the given transmission line through the detailed analysis and its assessment.

  • PDF

Analysis of Lighting Overvoltage and Induced Voltage of Neutral Line on the 22.9kV Combined Distribution Line (22.9kV 혼합배전선로의 뇌과전압 해석 및 중성선 유기 전압 해석)

  • Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.510-512
    • /
    • 2000
  • This paper describes the voltage induced at neutral line and the proper location of lightning arrester in combined 22.9 kV class distribution line jointed overhead line and cable each other Modeling is established in ATP Draw to perform simulation. Simulated distribution line at this paper consists of distribution line 4.2km and underground distribution line 2km. Overvoltage and induced voltage are analyzed at several point of combined line. Analysis results was compared to select the best point to install arrester. Such analysis technology will be applied to obtaining capacity and location of arrester in the similar combined distribution line.

  • PDF