• Title/Summary/Keyword: ASIL

Search Result 22, Processing Time 0.02 seconds

A Model of Operational Situation Analysis with Functional Safety for ASIL Determination (ASIL 결정을 위한 기능안전 운전상황 분석 모형)

  • Baek, Myoung-Sig;Jang, Hyeon Ae;Kwon, Hyuck Moo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.160-167
    • /
    • 2014
  • To determine a proper ASIL for each hazardous event with a proper safety goal, the right classes should first be determined for the three properties of the hazardous event; (i) severity of harm from the resultant accident, (ii) exposure to the relevant operational situation, and (iii) controllability to avoid the induced risks. ASIL can be clearly determined with right classes of these three properties. But no specific methodologies or processes for their classification can be found in ISO 26262, except only a rough guideline with a simplified set of illustrative tables. In this paper, we try to present a systematic model for classifying the three properties of the hazardous event and suggest a refined procedure of ASIL determination. The proposed model provides a specific method to get a more objective ASIL compared with that in the standard. Scrutinizing the current methodology, we develop a refined method and also provide an illustrative example.

A Modified Metric of FMEA for Risk Evaluation Based on ASIL of Safety System (ASIL에 기초하여 수정된 안전시스템 FMEA 위험평가척도)

  • Baek, Myoung-Sig;Jang, Hyeon Ae;Kwon, Hyuck Moo
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.4
    • /
    • pp.543-562
    • /
    • 2014
  • Purpose: The purpose of this study is to suggest a modified approach that compensates some shortcomings of RPN with relevant strength of ASIL for Safety System and suggests systematic and logical approach for FMEA. Methods: By comparing the objectives, determination procedures, and key conceptual differences of RPN and ASIL, a refined method of risk evaluation and a new risk metric are devised. Results: While the traditional FMEA provides only rough evaluation of relative risk for each failure, the proposed method compensates its shortcomings with relevant strength of ASIL and provides a more logical and practical procedure of risk evaluation. Conclusion: The new metric RPM provides not only a comparative priority rank but also the degree of physical seriousness. Besides, it may have even more benefits for various applications if the severity can be expressed as mone tary amount of losses.

Design and Verification of the Hardware Architecture for the Active Seat Belt Control System Compliant to ISO 26262 (ISO 26262에 부합한 능동형 안전벨트 제어 시스템의 하드웨어 아키텍처 설계 및 검증)

  • Lee, Jun Hyok;Koag, Hyun Chul;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2030-2036
    • /
    • 2016
  • This paper presents a hardware development procedure of the ASB(Active Seat Belt) control system to comply with ISO 26262. The ASIL(Automotive Safety Integrity Level) of an ASB system is determined through the HARA(Hazard Analysis and Risk Assessment) and the safety mechanism is applied to meet the reqired ASIL. The hardware architecture of the controller consists of a microcontroller, H-bridge circuits, passive components, and current sensors which are used for the input comparison. The required ASIL for the control systems is shown to be satisfied with the safety mechanism by calculation of the SPFM(Single Point Fault Metric) and the LFM(Latent Fault Metric) for the design circuits.

40-TFLOPS artificial intelligence processor with function-safe programmable many-cores for ISO26262 ASIL-D

  • Han, Jinho;Choi, Minseok;Kwon, Youngsu
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.468-479
    • /
    • 2020
  • The proposed AI processor architecture has high throughput for accelerating the neural network and reduces the external memory bandwidth required for processing the neural network. For achieving high throughput, the proposed super thread core (STC) includes 128 × 128 nano cores operating at the clock frequency of 1.2 GHz. The function-safe architecture is proposed for a fault-tolerance system such as an electronics system for autonomous cars. The general-purpose processor (GPP) core is integrated with STC for controlling the STC and processing the AI algorithm. It has a self-recovering cache and dynamic lockstep function. The function-safe design has proved the fault performance has ASIL D of ISO26262 standard fault tolerance levels. Therefore, the entire AI processor is fabricated via the 28-nm CMOS process as a prototype chip. Its peak computing performance is 40 TFLOPS at 1.2 GHz with the supply voltage of 1.1 V. The measured energy efficiency is 1.3 TOPS/W. A GPP for control with a function-safe design can have ISO26262 ASIL-D with the single-point fault-tolerance rate of 99.64%.

Basic Design of ECU Hardware for the Functional Safety of In-Vehicle Network Communication (차량 내 네트워크 통신의 기능안전성을 위한 하드웨어 기본 설계)

  • Koag, Hyun Chul;Ahn, Hyun-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1373-1378
    • /
    • 2017
  • This paper presents a basic ECU(Electronic Control Unit) hardware development procedure for the functional safety of in-vehicle network systems. We consider complete hardware redundancy as a safety mechanism for in-vehicle communication network under the assumption of the wired network failure such as disconnection of a CAN bus. An ESC (Electronic Stability Control) system is selected as an item and the required ASIL(Automotive Safety Integrity Level) for this item is assigned by performing the HARA(Hazard Analysis and Risk Assessment). The basic hardware architecture of the ESC system is designed with a microcontroller, passive components, and communication transceivers. The required ASIL for ESC system is shown to be satisfied with the designed safety mechanism by calculation of hardware architecture metrics such as the SPFM(Single Point Fault Metric) and the LFM(Latent Fault Metric).

ISO 26262 의 하드웨어 ASIL 정량적 평가 절차

  • Kim, Gi-Yeong;Jang, Jung-Sun
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.271-279
    • /
    • 2011
  • Automotive safety integrity level of hardware components can be achieved by satisfying quantitative and qualitative requirements. Based on ASIL, quantitative requirements are composed of hardware architectural metrics and evaluation of safety goal violations due to random hardware failures in ISO 26262. In this paper, the types of hardware failures will be defined and classified. Based on various metrics related with hardware failures, design essentials to achieve hardware safety integrity will be studied specifically. Issues associated with hardware development and assessment process are presented briefly.

  • PDF

Hazard Analysis of Autonomous Vehicle due to V2I Malfunction (V2I 오작동에 의한 자율주행자동차의 위험성 분석)

  • Ahn, Dae-ryong;Shin, Seong-geun;Baek, Yun-soek;Lee, Hyuck-kee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.6
    • /
    • pp.251-261
    • /
    • 2019
  • The importance of autonomous driving systems that utilize V2X services such as V2V(Vehicle to Vehicle) and V2I(Vehicle to Infrastructure) for safer and more comfortable driving is increasing with the recent development of autonomous vehicles. Partly autonomous vehicles based on environmental sensors have limitations for predicting and determining areas beyond the recognition distance of the mounted sensors and in response to atypical objects that are difficult to detect. Therefore, it is important to utilize the V2X service to improve the limit of sensor detection performance and to make driving safer and more comfortable. However, there may be an accident risk of autonomous vehicles due to incorrect information provided by V2X. Thus, the application of technology to prevent this needs to be considered. In this pater, we used the ISO-26262 Part3 Process and performed HARA (Hazard Analysis and Risk Assessment) to derive the risk sources of autonomous vehicles due to V2I malfunctions by using the communication between vehicles and infrastructure among V2X. We also developed ASIL ratings based on the simulations and real vehicle tests of the malfunctions of major cases of usnig V2I.

Using Model Checking to Verify an Automotive Electric Parking Brake System (자동차 전자식 주차 브레이크 시스템 안전 요구사항 검증을 위한 모델검증 적용)

  • Choi, Jun Yeol;Cho, Joon Hyung;Choi, Yun Ja
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.4
    • /
    • pp.167-176
    • /
    • 2017
  • There are increasing policies and safeguards to prevent various human resource losses with the development of automotive industry. Currently ISO26262 $1^{st}$ edition has been released in 2011 to ensure functional safety of electrical and electronic systems and the $2^{nd}$ edition will be released in the second half of 2016 as part of a trend. The E/E (Electrical & Electronics) system requirements verification is required through walk-through, 인스펙션, semi-formal verification and formal verification in ISO 26262. This paper describe the efficiency of model checking for the E/E system requirements verification by applying the product development project of ASIL (Automotive Safety Integrity Level) D for the electrical parking brake system.

Thoracic Extraosseous Epidural Cavernous Hemangioma

  • Yaldiz, Can;Asil, Kiyasettin;Ceylan, Davut;Erdem, Sahin
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.65-67
    • /
    • 2015
  • Cavernous hemangiomas were first reported in 1929 by Globus and Doshay, and are defined as benign vascular structures developed between the neural tissues occurring in the central nervous system, consisting of a dilated vascular bed. Cavernous hemangiomas comprise nearly 5-12% of all spinal vascular malformations; however, existence in the epidural space without bone involvement is rare. Only 4% of all cavernous hemangiomas (0.22/1.000.000) are purely epidural cavernous hemangiomas. In this case report, we removed a hemorrhagic thoracic mass presenting with progressive neurological deficits in a 55-year-old male patient. We found this case to be appropriate for presentation due to the rare occurrence of this type of cavernous hemangioma.