• Title/Summary/Keyword: APs

Search Result 1,785, Processing Time 0.027 seconds

A Stable Access Point Selection Method Considering RSSI Variation in Fingerprinting for Indoor Positioning (실내측위를 위한 핑거프린팅에서의 RSSI 변동을 고려한 안정된 AP 선출방법)

  • Hwang, DongYeop;Kim, Kangseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.9
    • /
    • pp.369-376
    • /
    • 2017
  • Recently, an RSSI-based fingerprinting localization technology has been widely used in indoor location-based services. In the conventional fingerprinting method, as many APs as possible are used to increase the accuracy of location estimation. In another study, a part of APs having the strongest RSSI signal intensity are selected and used to reduce the time spent for positioning. However, it does not reflect the influence of RSSI occurred from the changes of the surrounding environments such as human movement or moving obstacles in a real environment. The environmental changes may cause the difference between the predicted RSSI signal strength value and the measured value, and thus occur an unpredictable error in the position estimation. Therefore, in order to mitigate the error caused by environmental factors, it is necessary to select APs suitable for indoor positioning estimation considering the changes in the surrounding environments. In this paper, we propose a method to select stable APs considering the influence of surrounding environments and derive a suitable positioning algorithm. In addition, we compare and analyze the performance of the proposed method with that of the existing AP selection methods through experiments.

Study of Emulsion Polymerization Condition of Aqueous Adhesive (유화중합을 이용한 수분산성접착제의 중합조건에 관한 연구)

  • Lee, HaengJa;Park, JiSun;Lee, SangRok;Kim, JongMin;Chang, SangMok
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.470-475
    • /
    • 2009
  • To study the optimal synthesis conditions of aqueous acrylic adhesive using emulsion polymerization, the effects of monomer, surfactant and initiator on the adhesive properties, such as conversion rate, particle size, peel strength, and glass transition temperature, were investigated. 2-EHA, n-BA and MMA were used as main monomers, 2-HEMA and AAc as functional monomers, SLS as surfactant and APS as initiator, respectively. The conversion rate was over 95% at 3.75% surfactant(SLS/monomer), 0.612% initiator(APS/monomer) and $82^{\circ}C$ reaction temperature. When the excess amount of surfactant or initiator was used, the peel strength represented decreasing tendency. The maximum conversion rate and peel strength were obtained at 65% 2-EHA/monomer, 20% BA/monomer, and 10% MMA/monomer.

A Case of Primary Antiphospholipid Antibody Syndrome Showing Vegetation on the Mitral Valve Through Echocardiography (승모판에서 증식증(vegetation)이 확인된 원발성 항인지질 항체 증후군 1례)

  • Lee, Seung-Yeop;Park, Seung-Kwon;Yun, Sung-Hwan;Jung, Yun-Seok;Kim, Hyen-Jik;Lim, Sung-Hwan;Hah, Jung-Sang;Kim, Wook-Nyeun
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.350-358
    • /
    • 1998
  • Antiphospholipid antibody syndrome(APS) is a well-known clinical syndrome characterized by recurrent arterial or venous thromboses, recurrent fetal loss, thrombocytopenia, together with high titers of sustained anticardiolipin antibody(aCL) or lupus anticoagulant(LA). Although systemic lupus erythematosus(SLB) and APS may coexist, a high proportion of patients manifesting the APS do not suffer from classical lupus or other connective tissue disease. The patient has been defined as having a primary antiphospholipid antibody syndrome. We experienced one case of primary APS with recurrent fetal loss, recurrent cerebral infarctions, positive anticardiolipin antibody IgG and fluttering vegetation on the mitral valve, without other connective tissue diseases including SLE. Forty-three old female had 2 out of 11 criteria for the diagnosis of SLE, such as thrombocytopenia and positive antinuclear antibody, but did not meet whole criteria. The patient was treated with ticlopidine, and anticoagulant therapy was recommended.

  • PDF

Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement (TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교)

  • Kim, Du-Yong;Chung, Hyuck;Park, Jae-Hong;Hyun, Jun-Ho;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

A Rogue AP Detection Method Based on DHCP Snooping (DHCP 스누핑 기반의 비인가 AP 탐지 기법)

  • Park, Seungchul
    • Journal of Internet Computing and Services
    • /
    • v.17 no.3
    • /
    • pp.11-18
    • /
    • 2016
  • Accessing unauthorized rogue APs in WiFi environments is a very dangerous behavior which may lead WiFi users to be exposed to the various cyber attacks such as sniffing, phishing, and pharming attacks. Therefore, prompt and precise detection of rogue APs and properly alarming to the corresponding users has become one of most essential requirements for the WiFi security. This paper proposes a new rogue AP detection method which is mainly using the installation information of authorized APs and the DHCP snooping information of the corresponding switches. The proposed method detects rogue APs promptly and precisely, and notify in realtime to the corresponding users. Since the proposed method is simple and does not require any special devices, it is very cost-effective comparing to the wireless intrusion prevention systems which are normally based on a number of detection sensors and servers. And it is highly precise and prompt in rogue AP detection and flexible in deployment comparing to the existing rogue AP detection methods based on the timing information, location information, and white list information.

A Study on Curing Reaction of 1-Chlobutadiene-Butadiene Copolymer by Moisture (1-Chlorobutadiene-Butadiene Copolymer의 수가교반응(水架橋反應)에 관한 연구(硏究)(I))

  • Yoo, Chong-Sun;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.22 no.3
    • /
    • pp.195-203
    • /
    • 1987
  • In this study, as one of the developing ways of the functional elastomer, improvement of the functionality of CB-BR was attempted through moisture curing reaction. The curing reaction of CB-BR was determined with an use of 3-aminopropyltriethoxysilane(APS) as a crosslinking agent, also a solution reaction with an active chlorine of CB-BR was elucidated by using a reaction kinetics theory and a study of physical property was made through moisture curing on the compound of 3-aminopropyltriethoxysilane and CB-BR The results of this study obtained are as follows : 1) CB-BR reacted easily with APS in the liquid state and the reaction rate coefficient and activation energy were as follows : 2) Optimum pressure condition of moisture cured elastomer(CB-BR+APS) was 20 minutes at $150^{\circ}C$, and the crosslinked elastomer was close to the theoretical value (q=1) for Flory's equation($\frac{\alpha}{\alpha-1}=q{\nu}RT$)

  • PDF

Performance Analysis of Indoor Localization Algorithm Using Virtual Access Points in Wi-Fi Environment (Wi-Fi 환경에서 가상 Access Point를 이용한 실내 위치추정 알고리즘의 성능분석)

  • Labinghisa, Boney;Lee, Dong Myung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.3
    • /
    • pp.113-120
    • /
    • 2017
  • In recent years, indoor localization has been researched for the improvement of its localization accuracy capability in Wi-Fi environment. The fingerprint and RF propagation models has been the main approach in determining indoor positioning. With the use of fingerprint, a low-cost, versatile localization system can be achieved without the use of external hardware. However, only a few research have been made on virtual access points (VAPs) among indoor localization models. In this paper, the idea of indoor localization system using fingerprint with the addition of VAP in Wi-Fi environment is discussed. The idea is to virtually add APs in the existing indoor Wi-Fi system, this would mean additional virtually APs in the network. The experiments of the proposed algorithm shows the positive results when 2VAPs are used compared with only APs. A combination of 3APs and 2VAPs in the 3rd case had the lowest average error of 3.99 among its 4 scenarios.

A Selection Method of Reference Access Points to Improve the Localization Accuracy in Indoor Environments (실내 환경에서 측위 정확도 향상을 위한 기준 AP 선택 기법)

  • Lim, Yu-Jin;Park, Jae-Sung
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.6
    • /
    • pp.489-493
    • /
    • 2010
  • In an indoor localization method taking the lateration-based approach, the distance between a target and an AP (Anchor Point) is estimated using RSS (Received Signal Strength) measurements. Since the characteristics of a radio signal randomly vary in time and space, errors are unavoidable in distance estimation with measured RSS. Since the accuracy of distance estimation affects the localization accuracy of a lateration-based method, additional APs hearing a target have been used for localization in the literature. However, lots of experimental results show that the accuracy of a lateration-based method is improved by using carefully selected APs measuring the high quality RSSs which the distances estimated is close to the actual distances between nodes as reference APs, not using merely more APs. In this paper, we focus on selection method of reference AP and distance estimation method reflecting on environmental dynamics. We validate our method by implementing an indoor localization system and evaluating the accuracy of our method in the various experimental environments.

Adjusting the Sensitivity of an Active Pixel Sensor Using a Gate/Body-Tied P-Channel Metal-Oxide Semiconductor Field-Effect Transistor-Type Photodetector With a Transfer Gate (전송 게이트가 내장된 Gate/Body-Tied P-Channel Metal-Oxide Semiconductor Field-Effect Transistor 구조 광 검출기를 이용한 감도 가변형 능동 화소 센서)

  • Jang, Juneyoung;Lee, Jewon;Kwen, Hyeunwoo;Seo, Sang-Ho;Choi, Pyung;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.114-118
    • /
    • 2021
  • In this study, the sensitivity of an active pixel sensor (APS) was adjusted by employing a gate/body-tied (GBT) p-channel metal-oxide semiconductor field-effect transistor (PMOSFET)-type photodetector with a transfer gate. A GBT PMOSFET-type photodetector can amplify the photocurrent generated by light. Consequently, APSs that incorporate GBT PMOSFET-type photodetectors are more sensitive than those APSs that are based on p-n junctions. In this study, a transfer gate was added to the conventional GBT PMOSFET-type photodetector. Such a photodetector can adjust the sensitivity of the APS by controlling the amount of charge transmitted from the drain to the floating diffusion node according to the voltage of the transfer gate. The results obtained from conducted simulations and measurements corroborate that, the sensitivity of an APS, which incorporates a GBT PMOSFET-type photodetector with a built-in transfer gate, can be adjusted according to the voltage of the transfer gate. Furthermore, the chip was fabricated by employing the standard 0.35 ㎛ complementary metal-oxide semiconductor (CMOS) technology, and the variable sensitivity of the APS was thereby experimentally verified.

Threshold based User-centric Clustering for Cell-free MIMO Network (셀프리 다중안테나 네트워크를 위한 임계값 기반 사용자 중심 클러스터링)

  • Ryu, Jong Yeol;Lee, Woongsup;Ban, Tae-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.1
    • /
    • pp.114-121
    • /
    • 2022
  • In this paper, we consider a user centric clustering in order to guarantee the performance of the users in cell free multiple-input multiple-output (MIMO) network. In the user centric clustering scheme, by using large scale fading coefficients of the connected access points (APs), each user decides own cluster with the APs having the higher the large scale fading coefficients than threshold value compared to the highest large scale fading coefficient. In the determined user centric clusters, the APs design the beamformers and power allocations in the distributed manner and the APs cooperatively transmit data to users by using beamformers and power allocations. In the simulation results, we verify the performance of user centric clustering in terms of the spectral efficiency and we also find the optimal threshold value in the given configuration.