• Title/Summary/Keyword: APR+

Search Result 780, Processing Time 0.028 seconds

SEPARATE AND INTEGRAL EFFECT TESTS FOR VALIDATION OF COOLING AND OPERATIONAL PERFORMANCE OF THE APR+ PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Kang, Kyoung-Ho;Kim, Seok;Bae, Byoung-Uhn;Cho, Yun-Je;Park, Yu-Sun;Yun, Byoung-Jo
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.597-610
    • /
    • 2012
  • The passive auxiliary feedwater system (PAFS) is one of the advanced safety features adopted in the APR+, which is intended to completely replace the conventional active auxiliary feedwater system. With an aim of validating the cooling and operational performance of PAFS, an experimental program is in progress at KAERI, which is composed of two kinds of tests; the separate effect test and the integral effect test. The separate effect test, PASCAL ($\underline{P}$AF$\underline{S}$ $\underline{C}$ondensing Heat Removal $\underline{A}$ssessment $\underline{L}$oop), is being performed to experimentally investigate the condensation heat transfer and natural convection phenomena in PAFS. A single, nearly-horizontal U-tube, whose dimensions are the same as the prototypic U-tube of the APR+ PAFS, is simulated in the PASCAL test. The PASCAL experimental result showed that the present design of PAFS satisfied the heat removal requirement for cooling down the reactor core during the anticipated accident transients. The integral effect test is in progress to confirm the operational performance of PAFS, coupled with the reactor coolant systems using the ATLAS facility. As the first integral effect test, an FLB (feedwater line break) accident was simulated for the APR+. From the integral effect test result, it could be concluded that the APR+ has the capability of coping with the hypothetical FLB accident by adopting PAFS and proper set-points of its operation.

Physics study for high-performance and very-low-boron APR1400 core with 24-month cycle length

  • Do, Manseok;Nguyen, Xuan Ha;Jang, Seongdong;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.869-877
    • /
    • 2020
  • A 24-month Advanced Power Reactor 1400 (APR1400) core with a very-low-boron (VLB) concentration has been investigated for an inherently safe and high-performance PWR in this work. To develop a high-performance APR1400 which is able to do the passive frequency control operation, VLB feature is essential. In this paper, the centrally-shielded burnable absorber (CSBA) is utilized for an efficient VLB operation in the 24-month cycle APR1400 core. This innovative design of the VLB APR1400 core includes the optimization of burnable absorber and loading pattern as well as axial cutback for a 24-month cycle operation. In addition to CSBA, an Er-doped guide thimble is also introduced for partial management of the excess reactivity and local peaking factor. To improve the neutron economy of the core, two alternative radial reflectors are adopted in this study, which are SS-304 and ZrO2. The core reactivity and power distributions for a 2-batch equilibrium cycle are analyzed and compared for each reflector design. Numerical results show that a VLB core can be successfully designed with 24-month cycle and the cycle length is improved significantly with the alternative reflectors. The neutronic analyses are performed using the Monte Carlo Serpent code and 3-D diffusion code COREDAX-2 with the ENDF/B-VII.1.

A Study on the Surface Roughness Behavior of Reactor Vessel Stud Holes in APR1400 Nuclear Power Plants (APR1400 원자로 용기 스터드 홀의 표면거칠기 거동에 관한 연구)

  • Kim, Dong Il;Kim, Chang Hun;Moon, Young Jun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.62-70
    • /
    • 2019
  • The APR1400 reactor may be operated for a long time under high temperature and pressure conditions, causing damage to the stud holes and causing stud bolts and holes to stick. The present practice is to manually remove the anti-sticking agent and foreign matter remaining in the APR1400 reactor stud hole and to visually check the surface condition of the thread to check the damage status of the threads. In the case of the APR1400 reactor stud holes, manually cleaning the threads increases the risk of radiation exposure and operator's fatigue. To avoid this, the autonomous mobile robot is used to automatically clean the reactor stud holes. The purpose of this study is to optimize the cleaning performance of the mobile robot by looking at the behavior of the surface roughness of the stud surface cleaned by the brush attached to the mobile robot due to changes in brush material, thickness of wire, and rotation speed. A microscopic approach to the surface roughness of the flank is needed to investigate the effects of the newly proposed brush of the autonomous mobile robot on the thread holes. According to this experiment, it is reasonable to use STS brush rather than Carbon one. Optimal operating conditions are derived and the safety of APR1400 reactor stud holes maintenance can be improved.

Cloning and Expression of a Fibrinolytic Enzyme Gene, aprECJ1, from Bacillus velezensis CJ1 Isolated from Myeolchi Jeotgal

  • Yoo, Ji Yeon;Yao, Zhuang;Lee, Se Jin;Jeon, Hye Sung;Kim, Jeong Hwan
    • Microbiology and Biotechnology Letters
    • /
    • v.49 no.3
    • /
    • pp.289-297
    • /
    • 2021
  • Bacillus velezensis CJ1, showing significant fibrinolytic activity, was isolated from Myeolchi Jeotgal, a popular Korean fermented seafood. When B. velezensis CJ1 was grown on four different culture media, the culture on the Luria-Bertani (LB) broth showed the highest fibrinolytic activity (102.94 mU/μl) at 48 h. LB was also the best medium for growth. SDS-PAGE of culture supernatant showed four major bands, 38, 35, 27, and 22 kDa in size. Fibrin zymography showed four active bands, 50, 47, 40, and 30 kDa in size. A gene homologous to aprE of the Bacillus species was cloned by PCR. DNA sequencing showed that aprECJ1 can encode a protease consisting of 382 amino acids. The translated amino acid sequence of AprECJ1 showed high identity values with those of B. velezensis strains and other Bacillus species. The aprECJ1 gene was introduced into B. subtilis WB600 using an E. coli-Bacillus shuttle vector, pHY300PLK, and overexpressed. A 27 kDa band corresponding to the mature form of AprECJ1 was produced and confirmed by SDS-PAGE and fibrin zymography. B. subtilis WB600 [pHYaprECJ1] showed 1.8-fold higher fibrinolytic activity than B. velezensis CJ1 at 48 h.

Increase of a Fibrinolytic Enzyme Production through Promoter Replacement of aprE3-5 from Bacillus subtilis CH3-5

  • Yao, Zhuang;Meng, Yu;Le, Huong Giang;Lee, Se Jin;Jeon, Hye Sung;Yoo, Ji Yeon;Kim, Jeong Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.6
    • /
    • pp.833-839
    • /
    • 2021
  • Bacillus subtilis CH3-5 isolated from cheonggukjang secretes a 28 kDa protease with a strong fibrinolytic activity. Its gene, aprE3-5, was cloned and expressed in a heterologous host (Jeong et al., 2007). In this study, the promoter of aprE3-5 was replaced with other stronger promoters (Pcry3A, P10, PSG1, PsrfA) of Bacillus spp. using PCR. The constructed chimeric genes were cloned into pHY300PLK vector, and then introduced into B. subtilis WB600. The P10 promoter conferred the highest fibrinolytic activity, i.e., 1.7-fold higher than that conferred by the original promoter. Overproduction of the 28 kDa protease was confirmed using SDS-PAGE and fibrin zymography. RT-qPCR analysis showed that aprE3-5 expression was 2.0-fold higher with the P10 promoter than with the original promoter. Change of the initiation codon from GTG to ATG further increased the fibrinolytic activity. The highest aprE3-5 expression was observed when two copies of the P10 promoter were placed in tandem upstream of the ATG initiation codon. The construct with P10 promoter and ATG and the construct with two copies of P10 promoter in tandem and ATG exhibited 117% and 148% higher fibrinolytic activity, respectively, than that exhibited by the construct containing P10 promoter and GTG. These results confirmed that significant overproduction of a fibrinolytic enzyme can be achieved by suitable promoter modification, and this approach may have applications in the industrial production of AprE3-5 and related fibrinolytic enzymes.

MRI Findings in Trigeminal Neuralgia without Neurovascular Compression: Implications of Petrous Ridge and Trigeminal Nerve Angles

  • Hai Zhong;Wenshuang Zhang;Shicheng Sun;Yifan Bie
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.821-827
    • /
    • 2022
  • Objective: To determine the anatomical characteristics of the petrous ridge and trigeminal nerve in trigeminal neuralgia (TN) without neurovascular compression (NVC). Materials and Methods: From May 2017 to March 2021, 66 patients (49 female and 17 male; mean age ± standard deviation [SD], 56.8 ± 13.3 years) with TN without NVC and 57 controls (46 female and 11 male; 52.0 ± 15.6 years) were enrolled. The angle of the petrous ridge (APR) and angle of the trigeminal nerve (ATN) were measured using magnetic resonance imaging with a high-resolution three-dimensional T2 sequence. Data on the symptomatic side were compared with those on the asymptomatic side in patients and with the mean measurements of the bilateral sides in controls. Receiver operating characteristic (ROC) analysis was conducted to evaluate the performance of APR and ATN in distinguishing TN patients from controls. Results: In TN patients without NVC, the mean ± standard deviation (SD) of APR on the symptomatic side (98.40° ± 19.75°) was significantly smaller than that of the asymptomatic side (105.59° ± 22.45°, p = 0.019) and controls (108.44° ± 15.98°, p = 0.003). The mean ATN ± SD on the symptomatic side (144.41° ± 8.92°) was significantly smaller than that of the asymptomatic side (149.67° ± 8.09°, p = 0.003) and controls (150.45° ± 8.48°, p = 0.001). The area under the ROC curve for distinguishing TN patients from controls was 0.673 (95% confidence interval [CI]: 0.579-0.758) for APR and 0.700 (CI: 0.607-0.782) for ATN. The sensitivity and specificity using the diagnostic cutoff yielding the highest Youden index were 81.8% (54/66) and 49.1% (28/57), respectively, for APR (with a cutoff score of 94.30°) and 65.2% (43/66) and 66.7% (38/57), respectively, for ATN (cutoff score, 148.25°). Conclusion: In patients with TN without NVC, APR and ATN were smaller than those in controls, which may explain the potential cause of TN and provide additional information for diagnosis.

Screening Method for Flow-induced Vibration of Piping Systems for APR1400 Comprehensive Vibration Assessment Program (APR1400 종합진동평가를 위한 배관시스템의 유동유발진동 간이평가)

  • Ko, Do-Young;Kim, Dong-Hak
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.9
    • /
    • pp.599-605
    • /
    • 2015
  • The revised U.S. Nuclear Regulatory Commission(NRC), Regulatory Guide(RG) 1.20, rev.3 requires the evaluation of the potential adverse effects from pressure fluctuations and vibrations on piping and components for the reactor coolant, steam, feedwater, and condensate systems. Detailed vibration analyses for the systems attached to the steam generator are very difficult, because these piping systems are very complicated. This paper suggests a screening method for the flow-induced vibration of acoustic resonances and pump-induced vibration of the piping systems attached to the steam generator in order to conduct the APR1400 comprehensive vibration assessment program. This paper seeks to address the areas such as potential vibration sources, and methods to prevent the occurrence of acoustic resonances and pump-induced vibration of piping systems attached to the steam generator, for conducting the APR1400 comprehensive vibration assessment program. The screening method in this paper will be used to estimate the flow-induced vibration of the piping systems attached to the steam generator for the APR1400.