• Title/Summary/Keyword: APEX

Search Result 1,145, Processing Time 0.03 seconds

Evaluation of Effectiveness of New Design Lead Apron during Pregnant X-ray Chest P-A (임산부 흉부 촬영중 사용할 새로 디자인된 납치마의 효율성 평가)

  • Kim, Hyeonggyun;Kwon, Soonmu;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.441-445
    • /
    • 2012
  • X-ray Chest P-A is very important and basic diagnosis examination for pregnant women. For a pregnancy period pregnant women should be treated very carefully not to be exposed to any radiation which might cause harmful damage to women and babies as well. Lead apron is one of the effective methods to protect pregnant women from the X-ray radiation. However, it is difficult to obtain the accurate position of pregnant women during X-ray Chest P-A since conventional lead apron method forces pregnant women to hold the apron by themselves only to make pregnant women very uncomfortable and hard to maintain accurate position during radiation. As a consequence, it is common to get low quality images of X-ray Chest P-A due to the overlap of apex of lung and scapular. In order to fix this problem, we made new design lead apron that allowed pregnant women to be more comfortable to maintain accurate position during X-ray Chest P-A position. Finally, with this new design lead apron, it was possible to get the best optimized images of X-ray Chest P-A of pregnant women by minimizing overlapping apex of lung and scapular.

PSEUDOHYPOPARATHYROIDISM : CASE REPORT (가성부갑상선 기능저하증 환아의 구강 증상)

  • Kim, Seong-Oh;Hong, Eun-Kyoung;Choi, Hyung-Joon;Lee, Jae-Ho;Son, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.262-266
    • /
    • 2004
  • The parathyroid hormone plays a major role in the metabolism of calcium and phosphorus. In hypoparathyroidism the parathyroid glands are atrophied or absent associated with autoantibodies against parathyroid tissue. Pseudohypoparathyroidism is a metabolic disease caused by the disturbance in peripheral action of parathormone, but parathormone level is normal. In general, patients with pseudohypoparathyroidism have short stature, round face, brachydactylia, obesity, mental retardation, cataracts & ectopic calcifications on soft tissues. Dental manifestations are enamel hypoplasia, delayed eruption, blunting of root apex, hypodontia, pulp calcification, thickened lamina dura, excessive caries & malocclusion. In this case, intraoral examination showed enamel hypoplasia on the erupted permanent teeth & hypermobility on the remaining deciduous teeth. From the radiographic view severe dental anomalies were observed on canines and shortening and blunting of root apex was observed on mandibular incisors. Pathologic root resorption was also observed on deciduous teeth.

  • PDF

Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study (네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석)

  • Jeon, Sang-Je;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.359-370
    • /
    • 2006
  • The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis (3D FEA). The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. Four different lesion configurations representative of the various types observed clinically for teeth were studied. A static point load of 500N was applied to the buccal and lingual cusp (Load A and B). The principal stresses in lesion apex, and vertical sectioned margin of cervical wall were analyzed. The results were as follows 1. The patterns of stress distribution were similar but the magnitude was different in four types of lesion 2. The peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 3. The compressive stress under load A and the tensile stress under load B were dominant stress. 4. Under the load, lesion can be increased and harmful to tooth structure unless restored.

COMPARISON OF APICAL SEALING EFFICACIES USING DIFFERENT PLUGGING DEPTH IN CONTINUOUS WAVE OF OBTURATION TECHNIQUE (Continuous wave of obturation technique에서 플러거의 다양한 적용 깊이에 따른 근단부 폐쇄효율 비교)

  • Lee, Sang-Jin;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.491-497
    • /
    • 2007
  • The purpose of this study was to compare apical sealing ability of continuous wave canal filling technique according to various heat source plugging depths. Eighty one extracted human premolars with straight root were cleaned and shaped to size 35 using .06 taper rotary NiTi file. After cleansing and shaping, the teeth were divided into 5 groups following the heat source probing depths from the apex; 3, 4, 5, 6 and 7 mm. All specimens were filled using E&Q plus with #35/.06 tapered gutta-percha cone. The positive control teeth were not filled. All teeth were coated with nail varnish except the apical 1 mm around the apical foramen. Negative control teeth were completely sealed include the apical foramen. All specimens were immersed in 1% methylene blue solution for 72 hours. Then the specimens were sectioned horizontally at 1, 2 and 3 mm from the root apex. Each sectioned surface was photographed using a digital camera attached to the stereomicroscope at $12.5{\times}2.5$ fold magnification. All points at 1, 2 and 3 mm were summed as final score of one specimen. Statistical analysis of the collected data was performed. Under the condition of this study. there was no significant difference between the heat source plugging depths of 3, 4, 5, 6 and 7 mm in apical sealing ability. All of apical heat source plugging depth from 3 to 7 mm including Buchanan's protocol -from 5 to 7 mm- seems to be acceptable in clinical application.

EFFECTS OF ELECTRICAL STIMULATION ON THE NORMAL PERIODONTIUM (전기자극이 정상 치주조직에 미치는 영향)

  • Lim, Kyung-Seok;Kwon, Young-Hyuk;Lee, Man-sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.89-112
    • /
    • 2002
  • The earliest reports of the use of electrical energy to directly stimulate bone healing seem to be in 1853 from England, the techniques involved the introduction of direct current into the non-united fracture site percutaneously via metallic needles, with subsequent healing of the defect. One endpoint of the periodontal therapy is to generate structure lost by periodontal diseases. Several procedural advances may support regeneration of attachment, however, regeneration of alveolar bone does not occur consistently. Therefore, factors which stimulate bone repair are areas for research in periodontal reconstructive therapy. Effects of cytokines or growth factors on bone repair are examples of such areas. Another one is electrical current which occurs in bone naturally, so that such bone may be particularly susceptible to electrical therapy. The purposes of this study were to observe the effects of electrical stimulation on the normal periodontium, to determine whether the electricity is the useful means for periodontal regeneration or not. Forty rats weighted about 100 gram were used and divided into 4 groups, the first group, there was no electrical stimulation with the connection of electrodes only. In the second group, there was stimulated by the 10 mA during 10 minutes per a day, in the third group was stimulated by the 25 mA , and the fourth by the 50 mA. At 3, 5, 10 and 15 days post-appliance , two rats in each group were serially sacrificed. and the maxillae and the mandible processed to paraffin, and the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows : 1. There was the distinct reversal line on the lingual alveolar crest, whereas a little changes in the labial alveolarcrest to the duration and amount of currents. 2. In 50 mA group, the cells were highly concentrated at the apex of anterior teeth, and was observed the necrotic tissue. In posterior root apex, the hypercementosis was appeared, and newly formed cementum layer has been increased continuously with the time. 3. The periodontal ligament fiber and Sharpey's fiber were arranged in order, and the bone trabeculae were increased as the experiment proceeded by, relatively the bone marrows were decreased. 4. In the pulp tissue, the blood vessels were increased with blood congestion in the experimetal specimens remarkably, and the dentinal tubules were obstructed . 5. The osteoblasts in alveolar bone proper had been showed highly activity, and also observed the formation of bone trabeculea. In the conclusion, it was suggested that the electrical stimulation has influence on the periodontium and the pulp tissue. However, there might be the injurious effects.

STATISTICAL STUDY ON OPTIMAL PLACEMENT OF IMMEDIATE DENIAL IMPLANTATION USING DENTA $SCAN^R$ (Denta $Scan^R$을 이용한 즉시 임플랜트 시술시 최적의 식립 위치 대한 통계적 연구)

  • Shin, Kwang-Ho;Lee, Jai-Bong;Hwang, Byung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.552-560
    • /
    • 2000
  • Purpose : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. Materials and Method : From the years 1997 to 2000. 52 Denta $scan^R$ views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. On the Denta $scan^R$, the optimal placement for the immediated implantation was simulated. The measuring methods included 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. Result : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2 degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about $-2.8^{\circ}\;to\;-4.6^{\circ}$ with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively $11.8^{\circ}\;and \;7.2^{\circ}$ with the fixture center palatally positioned $2\sim2.4mm$ apart from tooth center. 4) At the lower premolar area, that was about $0^{\circ}\;to\;2^{\circ}$ with the fixture center's lingually positioned $0.5{\sim}1mm$ apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars. was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. Conclusion : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. In mandiblular anterior region, long axis of implants is lingully angulated compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.

  • PDF

Rabbit maxillary sinus augmentation model with simultaneous implant placement: differential responses to the graft materials

  • Kim, Young-Sung;Kim, Su-Hwan;Kim, Kyoung-Hwa;Jhin, Min-Ju;Kim, Won-Kyung;Lee, Young-Kyoo;Seol, Yang-Jo;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.204-211
    • /
    • 2012
  • Purpose: This study was performed to establish an experimental rabbit model for single-stage maxillary sinus augmentation with simultaneous implant placement. Methods: Twelve mature New Zealand white rabbits were used for the experiments. The rabbit maxillary sinuses were divided into 3 groups according to sinus augmentation materials: blood clot (BC), autogenous bone (AB), and bovine-derived hydroxyapatite (BHA). Small titanium implants were simultaneously placed in the animals during the sinus augmentation procedure. The rabbits were sacrificed 4 and 8 weeks after surgery and were observed histologically. Histomorphometric analyses using image analysis software were also performed to evaluate the parameters related to bone regeneration and implant-bone integration. Results: The BC group showed an evident collapse of the sinus membrane and limited new bone formation around the original sinus floor at 4 and 8 weeks. In the AB group, the sinus membrane was well retained above the implant apex, and new bone formation was significant at both examination periods. The BHA group also showed retention of the elevated sinus membrane above the screw apex and evident new bone formation at both points in time. The total area of the mineral component (TMA) in the area of interest and the bone-to-implant contact did not show any significant differences among all the groups. In the AB group, the TMA had significantly decreased from 4 to 8 weeks. Conclusions: Within the limits of this study, the rabbit sinus model showed satisfactory results in the comparison of different grafting conditions in single-stage sinus floor elevation with simultaneous implant placement. We found that the rabbit model was useful for maxillary sinus augmentation with simultaneous implant placement.

FPGA Implementation of Real-time 2-D Wavelet Image Compressor (실시간 2차원 웨이블릿 영상압축기의 FPGA 구현)

  • 서영호;김왕현;김종현;김동욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7A
    • /
    • pp.683-694
    • /
    • 2002
  • In this paper, a digital image compression codec using 2D DWT(Discrete Wavelet Transform) is designed using the FPGA technology for real time operation The implemented image compression codec using wavelet decomposition consists of a wavelet kernel part for wavelet filtering process, a quantizer/huffman coder for quantization and huffman encoding of wavelet coefficients, a memory controller for interface with external memories, a input interface to process image pixels from A/D converter, a output interface for reconstructing huffman codes, which has irregular bit size, into 32-bit data having regular size data, a memory-kernel buffer to arrage data for real time process, a PCI interface part, and some modules for setting timing between each modules. Since the memory mapping method which converts read process of column-direction into read process of the row-direction is used, the read process in the vertical-direction wavelet decomposition is very efficiently processed. Global operation of wavelet codec is synchronized with the field signal of A/D converter. The global hardware process pipeline operation as the unit of field and each field and each field operation is classified as decomposition levels of wavelet transform. The implemented hardware used FPGA hardware resource of 11119(45%) LAB and 28352(9%) ESB in FPGA device of APEX20KC EP20k600CB652-7 and mapped into one FPGA without additional external logic. Also it can process 33 frames(66 fields) per second, so real-time image compression is possible.

The morphology of Thalictrum L. in Korea (한국산 꿩의다리속(Thalictrum L.) 식물의 형태학적 연구)

  • Park , Seong-Jun;Park, Seon-Joo
    • Korean Journal of Plant Taxonomy
    • /
    • v.38 no.4
    • /
    • pp.433-458
    • /
    • 2008
  • This study were examined for their external morphological characters such as root, leaf, inflorescenses, flower, stamen, pistil, and fruit as to Korean Thalictrum L. and discussed taxanomic value of characters, and made out a new key. This study confirmed that specialized stems and roots type were divided into fibrous type, fibrous having a tuber type, long fusiform tuberous type, tuberoid type, rhizome type and stolon type. The stem were divided into two types based on existence and nonexistence of striate or pubescent. Leaves were usually 2-3-ternately and was divided into three types based on leaf apex, leaf base and number of lobe. Inflorescenses were divided into two type; corymb, panicle. Flower is bisexual, and don't have petal. It was divided from existence and nonexistence of calyx when it flowering. Especially, the stamens were divided from anther shape and apex shape, degree of dilation of filament, epidermic shape of filament etc., and the pistils were divided from glandular on ovary, length of carpel stipe etc.. The fruit is a achene and it was divided from achene shape, achene rib or wings, achene stipe length. This study suggest that useful characters for identifying section are degree of dilation of filament, anther shape, achene rib and wings, degree of dilation of achene. Also, roots, leaf shape, stamen and pistil shape, achene beak and achene length, achene and leaf hair appear to be useful characters for identifying species.

The Effect of Pd Coating on Electron Emission from Silicon Field Emitter Arrays (Pd 코팅이 실리콘 전계 방출 어레이의 전자 방출에 미치는 영향)

  • Lee, Jong-Ram;O, Sang-Pyo;Han, Sang-Yun;Gang, Seung-Ryeol;Lee, Jin-Ho;Jo, Gyeong-Ik
    • Korean Journal of Materials Research
    • /
    • v.10 no.4
    • /
    • pp.295-300
    • /
    • 2000
  • Uniform silicon tip arrays were fabricated using the reactive ion etching followed by the reoxidation sharpening, and the effect of Pd-coated layer on electron emission characteristics was studied. The electron emission from Si field emitter arrays(FEAs) was a little, but improved by removing surface oxide on the FEA, but pronounced drastically by coating a $100-{\AA}-thick$ Pd metal layer. The turn-on voltage in the Pd-coated Si FEAs was reduced by 30 V in comparison with that in uncoated ones. This results from the increase of surface roughness at the tip apex by the Pd coating on Si FEA, via the decrease of the apex radius at which electrons are emitting. The Pd-coated emitters showed superior operating stability over a wide current range to that of the uncoated ones. This suggests that Pd coating enhances the high temperature stability and the surface inertness Si FEA.

  • PDF