• Title/Summary/Keyword: APEX

Search Result 1,144, Processing Time 0.025 seconds

A Study of Mandibular Foramen and Mandibular Canal using Orthopantomograms. (Orthopantomogram을 이용한 하악공 및 하악관에 관한 연구)

  • Kim Hee-Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.13 no.1
    • /
    • pp.117-126
    • /
    • 1983
  • The mandibular canal must be considered carefully during surgical treatment, especially surgical extraction of the impacted tooth and intraosseous implant because it contains the important inferior alveolar nerve and vessels. The author investigated the curvatUre of the mandibular canal, the positional frequency of mandibular foramen to the occlusal plane and gonial angle and the positional frequency of the mental foramen to the tooth site using orthopantomograms. The materials consisted of 295 orthopantomograms divided into seven groups ranging from the first decade to 6th. decade. The results were as follows: 1. The position of mandibular foramen was most frequently below occlusal plane in Group Ⅰ (78.6%) and Group Ⅱ (71.2%), above occlusal plane in Group Ⅲ (63.0%), Group IV (71.1%), Group V (57.6%), Group (76.7%) and Group VII (70.0%). 2. The curvature of mandibular canal was 142.8° in Group Ⅰ, 142.09° in Group Ⅱ, 139.34° in Group Ⅲ, 141.48° in Group Ⅳ, 138.45° in Group Ⅴ, 140.77° in Group Ⅵ and 143.89° in Group Ⅶ. 3. The gonial angie was 125.82° in Group Ⅰ, 123.18° in Group Ⅱ, 124.06° in Group Ⅲ, 120.45° in Group Ⅳ, 121.12° in Group Ⅴ, 121.63° in Group Ⅵ and 121.24° in Group Ⅶ. 4. The position of the menta] foramen was most frequently below the apex of mandibular first premolar in Group Ⅰ (57.2%), between the apex of mandibular first and second premolar in Group Ⅱ (59.6%) and Group Ⅲ (48.9%), and below the apex of mandibular second premolar in Group Ⅳ (39.2%), Group Ⅴ (48.5%) Group Ⅵ(46.6%) and Group Ⅶ(56.4%)

  • PDF

Identification of Initiation Period and Subsequent Development of Floral Primordia in Black Locust (Robinia pseudoacacia L.)

  • Lee, Kyung Joon;Hong, Bongghi
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.2 s.159
    • /
    • pp.67-72
    • /
    • 2005
  • The objectives of this study were to identify the period of initiation of floral primordia in black locust (Robinia pseudoacacia L.) and subsequent development of floral buds until following spring. Four mature trees of black locust located in Suwon, Korea were selected. Bud samples were collected from the current-year shoots, starting from mid June to July every week, from August to October and from February to April every month. The buds were fixed in FAA solution, dehydrated, and imbedded in paraffin for microscopic observation. Buds collected on June 16, and 23, 1997, contained primitive primordia that might be interpreted as early floral primordia. By June 30, a bud showed a positive indication of inflorescence primordium with a well-formed shoot apex. All the inflorescence primordia observed throughout the collection periods were always associated with unique hairy appendages around the primordium and enclosed within a sclerenchymatous chamber. By July 7 and 15, a floral apex had early bud scales. By July 22, primitive inflorescence developed into visible arrangement of individual floral primordial By July 29, the inflorescence developed into whirl arrangement of individual floral primordia in a transverse section, but showed little further development until October 15. The inflorescence primordia seemed to over-winter at this stage. Buds collected from February 15 and March 24 the following year also showed no further development of inflorescence primordia. By April 7 the inflorescence started to show further development with elongated axis. At this time individual flowers were easily recognized.

The Effects of Growth Regulators and Medium Strength on the Shoot and Bud Formation from the Shoot Apex of Chinese Yam (Dioscorea opposita Thunb)

  • Shin, Jong-Hee;Kang, Dong-Kyoon;Park, Sang-Zo;Lee, Bong-Ho;Sohn, Jae-Keun
    • Journal of Plant Biotechnology
    • /
    • v.6 no.2
    • /
    • pp.103-106
    • /
    • 2004
  • Plantlet regeneration from the shoot apex was studied in three different genotypes of the chinese yam (Dioscorea opposita Thunb) cv. Jnagma and Danma, Dunggunma. The effects of plant growth regulators and inorganic salts concentration of the culture medium on bud induction and shoot growth were examined. The combinations of 0.2 mg/L BAP + 0.2mg/L kinetin, 0.01mg/L NAA + 0.2 mg/L kinetin and a single treatment of 0.2mg/L BAP were equally effective for bud and shoot formation from the shoot apices in the three cultivars. Auxin (2,4-D, NAA) treatment enhanced calli formation from the cultured apices. Also, the shoot apices of the cv. Dunggunma produced more callus and buds on the culture medium (MS) containing 0.05mg/L NAA and 0.5-1.0mg/L SAP. Lower salt strength of medium inhibited shoot elongation but did not have much effect on the shoot and bud induction from the shoot apices. These results will be useful to obtain disease-free plants of the Chinese yam.

Clinical Experience of Foreign Body Granuloma in the Apex of Orbit (안와첨부 이물 육아종의 치험례)

  • Paik, Hye Won;Choi, Jong Woo;Chong, Hyun Kwon;Lee, Paik Kwon;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.32 no.1
    • /
    • pp.131-134
    • /
    • 2005
  • It is often difficult to identify and localize intraorbital foreign bodies despite of modern high-resolution imaging investigation. Especially, posteriorly located foreign bodies have increased risks of morbidity that surgical approach is often complicated. No matter how trivial it seems, retained foreign body, particularly organic in nature, may give rise to severe orbital and cerebral complications. High clinical suspicion, proper diagnostic studies, timely referral to a skilled orbital surgeon are mandatory. We report a case of intraorbital wooden foreign body that required two separate exploration for removal. Initial exploration failed to identify and locate the foreign body completely. After the operation, fistula formation and purulent discharge were developed and the imaging investigation results were equivocal, complicating the management. A second exploration yielded multiple intraorbital wooden foreign body in the apex of orbit. The patient fully recovered without complication. The evaluations and the details of management strategy are discussed.

Three-dimensional and topographic relationships between the orbital margins with reference to assessment of eyeball protrusion

  • Shin, Kang-Jae;Lee, Shin-Hyo;Koh, Ki-Seok;Song, Wu-Chul
    • Anatomy and Cell Biology
    • /
    • v.50 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • This study investigated the topographic relationships among the eyeball and four orbital margins with the aim of identifying the correlation between orbital geometry and eyeball protrusion in Koreans. Three-dimensional (3D) volume rendering of the face was performed using serial computed-tomography images of 141 Koreans, and several landmarks on the bony orbit and the cornea were directly marked on the 3D volumes. The anterior-posterior distances from the apex of the cornea to each orbital margin and between the orbital margins were measured in both eyes. The distances from the apex of the cornea to the superior, medial, inferior, and lateral orbital margins were 5.8, 5.8, 12.0, and 17.9 mm, respectively. Differences between sides were observed in all of the orbital margins, and the distances from the apex of the cornea to the superior and inferior orbital margins were significantly greater in females than in males. The anterior-posterior distance between the superior and inferior orbital margins did not differ significantly between males (6.3 mm) and females (6.2 mm). The data obtained in this study will be useful when developing practical guidelines applicable to forensic facial reconstruction and orbitofacial surgeries.

A new minimally invasive guided endodontic microsurgery by cone beam computed tomography and 3-dimensional printing technology

  • Kim, Jong-Eun;Shim, June-Sung;Shin, Yooseok
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.29.1-29.7
    • /
    • 2019
  • Endodontic microsurgery is defined as the treatment performed on the root apices of an infected tooth, which was unresolved with conventional root canal therapy. Recently, the advanced technology in 3-dimensional model reconstruction based on computed tomography such as cone beam computed tomography has opened a new avenue in application of personalized, accurate diagnosis and has been increasingly used in the field of dentistry. Nevertheless, direct intra-oral localization of root apex based on the 3-dimensional information is extremely difficult and significant amount of bone removal is inevitable when freehand surgical procedure was employed. Moreover, gingival flap and alveolar bone fenestration are usually required, which leads to prolonged time of surgery, thereby increasing the chance of trauma as well as the risk of infection. The purpose of this case report is to present endodontic microsurgery using the guide template that can accurately target the position of apex for the treatment of an anterior tooth with calcified canal which was untreatable with conventional root canal therapy and unable to track the position of the apex due to the absence of fistula.

Stress distribution of Class V composite resin restorations: A three-dimensional finite element study (5급 복합레진수복물의 응력분포에 관한 3차원 유한요소법적 연구)

  • Park, Jeong-Kil;Hur, Bock;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.28-38
    • /
    • 2008
  • This study was to investigate the influence of composite resins with different elastic modulus, cavity modification and occlusal loading condition on the stress distribution of restored notch-shaped noncarious cervical lesion using 3-dimensional (3D) finite element (FE) analysis. The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. A notch-shaped cavity and a modified cavity with a rounded apex were modeled. Unmodified and modified cavities were filled with hybrid or flowable resin. After restoration, a static load of 500N was applied in a point-load condition at buccal cusp and palatal cusp. The stress data were analyzed using analysis of principal stress. The results were as follows: 1. In the unrestored cavity, the stresses were highly concentrated at mesial CEJ and lesion apex and the peak stress was observed at the mesial point angle under both loading conditions. 2. After restoration of the cavity, stresses were significantly reduced at the lesion apex, however cervical cavosurface margin, stresses were more increased than before restoration under both loading conditions. 3. When restoring the notch-shaped lesion, material with high elastic modulus worked well at the lesion apex and material with low elastic modulus worked well at the cervical cavosurface margin. 4. Cavity modification the rounding apex did not reduce compressive stress, but tensile stress was reduced.

A FINITE ELEMENT ANALYSIS ON THE 3-UNIT FIXED PROSTHESIS SUPPORTED WITH A NATURAL TOOTH AND ANGLE VARIABLE IMPLANT (고정성 보철치료에서 골유착성 임프란트의 경사도변화에 따른 변위와 응력에 관한 유한요소적 연구)

  • Ko Hyun;Woo Yi-Hyung;Park Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.580-610
    • /
    • 1993
  • The purpose of this study was to analyse the deflection and stress distribution at the supporting bone and it's superstructure by the alteration of angulation between implant and it's implant abutment. For this study, the free-end saddle case of mandibular first and second molar missing would be planned to restore with fixed prosthesis. So the mandibular second premolar was prepared for abutment, and the cylinder type osseointegrated implant was placed at the site of mandibular second molar for abutment. The finite element stress analysis was applied for this study. 13 two-dimensional FEM models were created, a standard model at $0^{\circ}$ and 12 models created by changing the angulation between implant and implant abutment as increasing the angulation mesially and distally with $5^{\circ}$ unittill $30^{\circ}$. The preprocessing decording, solving and postprocessing procedures were done by using FEM analysis software PATRAN and SUN-SPARC2GX. The deflections and von Mises stresses were calculated under concentrated load (load 1) and distributed load(load 2) at the reference points. The results were as follows : 1. Observing at standard model, the amount of total deflection at the distobuccal cusp-tip of pontic under concentrated load was largest of all, and that at the apex of implant was least of all, and the amount of total deflection at the buccal cusp-tip of second premolar under distributed load was largest of all, and that at the apex of implant was least of all. 2. Increasing the angulation mesially or distally, the amounts of total deflection were increased or decreased according to the reference points. But the order according to the amount of total deflection was not changed except apex of second premolar and central fossa of implant abutment under concentrated load during distal inclination. 3. Observing at standard model, the von Mises stress at the distal joint of pontic under concentrated load was largest of all, and that at the apex of implant was least of all. The von Mises stress at the distal margin of second premolar under distributed load was largest of all, and that at the apex of Implant was least of ail. 4. Increasing the angulation of implant mesially, the von Mises stresses at the mesial crest of implant were increased under concentrated load and distributed load, but those were increased remarkably under distributed load and so that at $30^{\circ}$ mesial inclination was largest of all. 5. Increasing the angulation of implant distally, the von Mises stresses at the distal crest of implant were increased remarkably under concentrated load and distributed load, and so those at $30^{\circ}$ distal inclination were largest of all.

  • PDF

Analysis of Clinical and Radiological Outcomes in Microsurgical and Endovascular Treatment of Basilar Apex Aneurysms

  • Jin, Sung-Chul;Ahn, Jae-Sung;Kwun, Byung-Duk;Kwon, Do-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.224-230
    • /
    • 2009
  • Objective : We aimed to analyze clinical and radiological outcomes retrospectively in patients with basilar apex aneurysms treated by coiling or clipping. Methods : Outcomes of basilar bifurcation aneurysms were assessed retrospectively in 77 consecutive patients (61 women, 16 men), ranging in age from 25 to 79 years (mean, 53.7 years) from 1999 to 2007. Results : Forty-nine patients out of 77 patients (63.6%) presented with subarachnoid hemorrhages of the 49 patients treated with coiling, 27 (55.1 %) showed complete occlusion of the aneurysm sac. Of these, 13 patients (26.5%) developed coil compaction on angiographic or MRI follow-up, with recoiling required in 9 patients (18.4%). Procedural complications of coiling were acute infarction in nine patients and the bleeding of the aneurysms in six patients. The remaining 28 patients underwent microsurgery : twenty-six of these (92.9%) with microsurgery followed up with conventional angiography. Complete occlusion of the aneurysm sac was achieved in 19 patients (73.1%). Operation-related complications of microsurgery were thalamoperforating artery injuries in three patients, retraction venous injury in two, postoperative epidural hemorrhage (EDH) in one, and transient partial or complete occulomotor palsy in 14 patients. Glasgow Outcome Scores (GOS) were 4 or 5 in 21 of 28 (75%) patients treated with microsurgery at discharge, and at 6 month follow-up, 20 of 28 (70.9%) maintained the same GOS. In comparison, GOS of four or 5 was observed in 36 of 49 (73.5%) patients treated with coiling at discharge and at 6 month follow-up, 33 of 49 patients (67.3%) maintained the GOS from discharge. Conclusion : Basilar top aneurysms were still challenging lesions based on our series. Endovascular or microsurgery endowed with its inborn risks and procedural complications for the treatment of basilar apex aneurysms individually. Microsurgery provided better outcome in some specific basilar apex aneurysms. For reaching the most favorable outcome, endovascular modality as well as microsurgery was inevitably considered for each specific basilar apex aneurysm.

Development of a Frequency Dependent Type Apex Locator with Automatic Compensation (자동 보정 주파수 의존형 근관장 측정기의 개발)

  • Kim, Deok-Won;Nam, Gi-Chang;Kim, Yeong-Ju;Lee, Seung-Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.6
    • /
    • pp.595-602
    • /
    • 1998
  • Among the apex locators, the frequency dependent type is more accurate and convenient to use than others, But the accuracy of the apex locator is still influenced by the presence of various electrolytes used in root canal treatments. In this study, we have developed a frequency dependent electronic apex locator minimizing the influence of the electrolytes on the measurement of root canal lengths. It was also confirmed that two frequencies of 500Hz and 100kHz are optimal for the measuring impedance compare with commercial product used(400Hz and 8kHz)a and there were no differences in accuracy among the three different types of the waveforms; sinusoidal, triangular, and rectangular waves(p>0.05). Impedance ratio of the two different frequencies represents the position of the file in root canal, and the voltage difference of two signals represents the status of the fluid in the root canal. As a result of compensation using the voltage differences, the errors were decreased on the average from +0.54mm to +0.18mm in $H_2O_2$ solution (p<0.01), and from -0.33mm to -0.01mm in NaOCl solution(p<0.01). The accuracies based on ${\pm}$0.5mm, in $H_2O_2$ and NaOCl solutions were improved with the automatic compensation from 71.1% and 91.1% to 82.2% and 100% respectively.

  • PDF