• Title/Summary/Keyword: ANSI N13.1

Search Result 15, Processing Time 0.022 seconds

Development of Algorithm for Evaluation of the Dose with Thermoluminescence Dosimeter (열형광선량계에 의한 선량평가 알고리즘 개발)

  • Song, Myung-Jae;Kim, Hee-Keun;Ha, Chung-Woo;Lee, Tae-Young;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.2
    • /
    • pp.1-13
    • /
    • 1992
  • The purpose of this study is to develop an algorithm of TLD dose evaluation to meet all requirements stated in ANSI N13. 11-1983. It made the PB-3 TLD of Teledyne Isotopes an object of the development. Personal dosimetry performance testings of the development algorithm have been performed twice through the Atlan-Tech, INC. in accordance with the criteria of testing described in ANSI N13. 11-1983. As ,a result, it is assured that the developed algorithm has complied with all requirements stated in ANSI N13. 11-1983.

  • PDF

말단선량계의 광자에 대한 선량환산인자의 이론적 계산

  • 김광표;이원근;이상윤;윤석철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.883-888
    • /
    • 1995
  • 본 연구에서 말단선량계에 대한 선량평가시 선량환산인자를 산출하기 위해 1995년의 ANSI N13.32 기준인 “말단선량계의 성능평가를 위한 기준”에서 제안된 기준 팬덤을 가지고 MCNP 전산코드를 이용하여 커마근사법에 의해 수행하였다. ANSI N13.32의 기준팬텀은 손·발 그리고 손가락을 대표하는 원통형으로서 특히 손·발 팬텀에 대해서는 뼈등가물질로 알루미늄을 삽입한 것을 제안함에 따라 본 계산 목적을 위하여 팬텀설계를 똑같이 모사하였으며 사용된 광자빔 에너지는 20keV에서부터 1.5MeV에 걸쳐 14개의 단일에너지를 선택하여 수행하였다. 본 연구에서 전산수행한 결과를 ANSI N13.32의 실험적 결과와 비교해 볼 때 50keV에서부터 1.5 MeV까지의 에너지 영역에서는 최대오차 6% 이내에서 거의 일치함을 보였다.

  • PDF

A Theoretical Calculation of Photon Dose Equivalent Conversion Factor For Extremity Dosimeter (말단선량계의 광자선량당량환산인자에 대한 이론적 계산)

  • Kim, Kwang-Pyo;Lee, Won-Keun;Kim, Jong-Su;Yoon, Yeo-Chang;Yoon, Suk-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.41-50
    • /
    • 1996
  • In this study, the theoretical calculation of the air kerma-to-dose equivalent conversion factors was performed with a Monte Carlo N-Particle transport code for the two types of extremity phantom of the ANSI and the KAERI, respectively. Considering the distribution of absorbed dose due to the interaction of homogeneous Parallel broad beam of monoenergetic primary photons in the range between 15keV and 1.5MeV, the air kerma-to-dose equivalent conversion factors based on the kerma approximation were calculated. It is showed that all the theoretical conversion factors of the two types of the extremity phantom for the ANSI and the KAERI agree well with the experimental values of the ANSI N13.32 draft(1995) for each energy within 5.7%, maximum difference ratio, except for 13.6%, difference ratio in the case for the energy of less than 40keV. It is due to uncertainties of experiment occurred in the low X-ray energy range and geometry considered in the MCNP code.

  • PDF

ANSI 13.32 말단부 팬템에 의한 열형광말단선량계의 방향의존성 연구

  • 김종수;윤석철;윤여창
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.889-894
    • /
    • 1995
  • 본 연구에서는 ANSI N13.32(1995)에서 제시한 손가락, 손목/발목 기준 팬텀(1)을 설계 제작하여 Teledye사의 말단선량계(finger와 wrist dosimeter)에 대한 방향의존성 실험을 수행하였다. 방사선원으로는 PTB 2차 베타표준선원 $^{204}$Tl(0.24 MeV), $^{90}$ sr/Y(0.8 MeV) 그리고 $^{l37}$ Cs(0.66 MeV) 표준 감마선원을 사용하였으며, 말단선량계로는 LiF Teflon(D-LiF-7-0.13)을 사용하였다. 90$^{\circ}$ 에서 $10^{\circ}$ 까지 20$^{\circ}$ 씩 수직과 수평으로 팬텀을 회전하여 정상각과 비정상각에 대한 상대응답을 제시하였다. 실험결과 90$^{\circ}$에서 모든 선량계는 잘 일치하였다. $^{90}$ Sr/Y은 50$^{\circ}$ 정도에서 다소 방향의존성이 적은 결과를 보였으며, $^{204}$ TI는 20$^{\circ}$에서 최소 13% 정도의 심한 방향의존성이 나타났다. 또한 $^{137}$Cs은 $10^{\circ}$에서도 최대 10.6% 정도의 적은 방향의존성을 나타냈다. 본 실험의 결과로부터 말단선량계는 저에너지와 낮은 투과 방사선[2]에서 심하게 방향의존성이 나타남을 알 수 있었다.

  • PDF

Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements (한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교)

  • Chang, Si-Yeong;Kim, Bong-Hwan;Kim, Jang-Lyul;McDonald, J.C.;Murphy, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.255-262
    • /
    • 1996
  • This paper describes the results of intercomparison measurements of KAERI reference photon and beta radiation fields between the KAERI and the PNNL(Pacific Northwest National Laboratory), recently performed at KAERI radiation calibration and dosimetry laboratory on the basis of the ANSI N13.11 criteria for personal dosimeter performance test. Each laboratory used her own radiation detectors or measurement devices traceable to her national primary standard in measuring the exposure rates for photon fields, the absorbed dose rates for beta radiation fields. The agreements in reference radiation measurements between two laboratories were found to be less than ${\pm}2.0%$ for photon fields, ${\pm}1.0%$ for beta radiation fields. Therefore, it could be concluded that KAERI reference radiation fields comply well with the international standard and thus can further serve as a national basis for the researches and developments in radiation protection dosimetry in Korea.

  • PDF

The Development and It′s Characteristics of New Film Dosimetry Algorithm for Personal Dosimetry (개인피폭 선량 측정을 위한 필름 배지 선량계의 새로운 알고리즘 개발 및 특성)

  • 이병용;장혜숙;봉정균;권수일
    • Progress in Medical Physics
    • /
    • v.6 no.2
    • /
    • pp.35-40
    • /
    • 1995
  • Purpose: We have developed new film dosimetry algorithm for personal dosimetry and examined its characteristics. Materials and methods: Agfagaevart personal monitoring 2/10 films are used. Films which are in the film badges filtered with Cu 0.3mm, plastic 1.5mm, Aluminum 0.6mm and tin 0.8mm, were exposed by standard dosimetry laboratory. Irradiated energy categories are ANSI N13.1l Category III, and IV. Manual type film precessor and X-rite film densitometor was used. Filtered densities to energy relations and does to transformed densities relations can be obtained ofter transformation of H&D curves to linear shape by polynomal fitting. Reults : Personal dose be determined within 25% error for category m and 15% for category IV. And we are able to evaluate the exposed energy. Conclusion : New algorithm developed in this study is good for personal dosimetry within 30% error range for catergory III and IV. It is expectd to be complete personal dosimetry algorithm with further study for categrory, I, Dand II V.

  • PDF

Development of Dose Evaluation Algorithm for Film Badge Using ISO Reference Radiations (ISO 표준방사선장을 이용한 필름배지의 선량평가 알고리즘 개발)

  • Kim, Jang-Lyul;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.37-44
    • /
    • 1995
  • Since provisions on the technical criteria for personnel dosimetry was amended three years ago, several improvements in the technique of monitoring personnel doses by TLD have taken place, but for the photograpfic film as a personnel monitor, additional investigations should be carried out for its accuracy of dose estimates because of its wide use in the radiation involved industries. So, this paper describes the methods to develope dose evaluation algorithm for photographic film using ISO reference radiations by i) empirical formula, ii) degree-of-fit method, and iii) matrix approximation. These methods show a good agreement between irradiated and calculated dose within tolerance level represented in ANSI N13. 11, and can be used for the dose evaluation of X, ${\gamma}$ and/or radiation fields.

  • PDF

A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants (원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.151-160
    • /
    • 2008
  • In Korean nuclear power plants (NPPs), two thermoluminescent dosimeters (TLD) were provided to workers who work in an inhomogeneous radiation field; one on the chest and the other on the head. In this way, the effective dose for radiation workers at NPPs was determined by the high deep dose between two radiation dose from these TLDs. This represented a conservative method of evaluating the degree of exposure to radiation. In this study, to prevent the overestimation of the effective dose, field application experiments were implemented using two-dosimeter algorithms developed by several international institutes for the selection of an optimal algorithm. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, NCRP (55/50), NCRP (70/30), EPRI (NRC), Lakslumanan, and Kim (Texas A&M University) were extensively analyzed as two-dosimeter algorithms. In particular, three additional TLDs were provided to radiation workers who wore them on the head, chest, and back during maintenance periods, and the measured value were analyzed. The results found no significant differences among the calculated effective doses, apart from Lakshmanan's algorithm. Thus, this paper recommends the NCRP(55/50) algorithm as an optimal two-dosimeter algorithm in consideration of the solid technical background of NCRP and the convenience of radiation works. In addition, it was determined that a two-dosimeter is provided to a single task which is expected to produce a dose rate of more than 1 mSv/hr, a difference of dose rates depending on specific parts of the body of more than 30%, and an exposure dose of more than 2 mSv.