• 제목/요약/키워드: AMD(active mass driver)

검색결과 13건 처리시간 0.018초

지진시 구조물의 지능제어 기법 (Intelligent Control of structures under Earthquakes)

  • 김동현;이규원;이종헌;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 봄 학술발표회논문집
    • /
    • pp.271-276
    • /
    • 2000
  • Optimal neuro-control algorithm is extended to the control of a multi-degree-of-freedom structure. An active mass driver(AMD) system on the top roof used as a controller. The control signals are made by a multi-layer perceptron(MLP) which is trained by minimizing a sub-optimal performance index. The performance index is a function of both the output responses and the control signals. Structure having nonlinear hysteretic behavior is also trained and controlled by using proposed control algorithm. Bothe the time delay effect and the dynamics of hydraulic actuator are included in the simulation. Example shows that optimal neuro-control algorithm can be applicable to the multi-degree of freedom structures.

  • PDF

건물의 진동제어를 위한 LQG제어기 (LQG Controller for the Vibration Control of Building Structures)

  • 민경원;이성경
    • 한국전산구조공학회논문집
    • /
    • 제12권2호
    • /
    • pp.243-249
    • /
    • 1999
  • 지진력을 받는 건물의 응답을 능동적으로 제어하기 위해서는 건물의 응답을 측정하고, 이것을 바탕으로 제어력을 산정하여야 한다. 제어력의 산정 방법에는 여러 제어 알고리듬이 적용이 될 수 있는데, 2차 성능지수를 이용하는 LQ제어는 해석의 용이함과 제어의 효율성으로 인하여 널리 쓰이고 있다. 그러나, LQ제어에는 실시간으로 계측이 된 건물의 지반과의 상대 변위 및 속도를 필요로 하나 이러한 상태 변수를 계측하기가 매우 어려워 건물의 제어를 위한 적용에 한계가 있다. 따라서, 계측이 용이한 건물의 절대 가속도를 바탕으로 관측이 용이한 건물의 절대 가속도를 바탕으로 관측기를 이용하여 상태 변수를 추정하여 제어력을 산정하는 LQC 제어 알고리듬이 지진력을 받는 건물에 대한 실용적인 알고리듬이 될 수 있다. 본 연구에서는 이러한 LQC 알고리듬의 성능을 검증하기 위하여 능동제어추진기가 설치된 축소 1층 모형에 대한 해석 및 실험을 수행하였으며, 그 결과 LQC 알고리듬의 제어 효율을 확인할 수 있었다.

  • PDF

Model reduction techniques for high-rise buildings and its reduced-order controller with an improved BT method

  • Chen, Chao-Jun;Teng, Jun;Li, Zuo-Hua;Wu, Qing-Gui;Lin, Bei-Chun
    • Structural Engineering and Mechanics
    • /
    • 제78권3호
    • /
    • pp.305-317
    • /
    • 2021
  • An AMD control system is usually built based on the original model of a target building. As a result, the fact leads a large calculation workload exists. Therefore, the orders of a structural model should be reduced appropriately. Among various model-reduction methods, a suitable reduced-order model is important to high-rise buildings. Meanwhile, a partial structural information is discarded directly in the model-reduction process, which leads to the accuracy reduction of its controller design. In this paper, an optimal technique is selected through comparing several common model-reduction methods. Then, considering the dynamic characteristics of a high-rise building, an improved balanced truncation (BT) method is proposed for establishing its reduced-order model. The abandoned structural information, including natural frequencies, damping ratios and modal information of the original model, is reconsidered. Based on the improved reduced-order model, a new reduced-order controller is designed by a regional pole-placement method. A high-rise building with an AMD system is regarded as an example, in which the energy distribution, the control effects and the control parameters are used as the indexes to analyze the performance of the improved reduced-order controller. To verify its effectiveness, the proposed methodology is also applied to a four-storey experimental frame. The results demonstrate that the new controller has a stable control performance and a relatively short calculation time, which provides good potential for structural vibration control of high-rise buildings.