• Title/Summary/Keyword: AISC

Search Result 276, Processing Time 0.027 seconds

Self-Optimizing Structural Design of a Pre-engineered Building System with Nonprismatic Members based on AISC2005 (AISC2005에 기준한 변단면 선설계 건축물시스템의 자동화 최적구조설계)

  • Kim, Yong Seok;Oh, Myoung Ho;Song, Byung Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.2
    • /
    • pp.193-201
    • /
    • 2009
  • Structural design of most nonprismatic Pre-Engineered Building Systems (PEBS) is performed using optimizing software developed in foreign countries. In this study, a structural optimizing software for the design of 3-D structures of nonprismatic PEBS is developed according to the allowable stress design method of AISC2005 and KBC. Optimizing structural design with nonprismatic members is carried out by repeating the process of structural analysis and member design to minimize the weight of a structure. According to the optimizing design results of 2-D and 3-D structures with nonprismatic members, there are considerable steel savings in designing structures with nonprismatic H-shaped built-up sections rather than with H-shaped rolled sections. When H-shaped built-up sections were used, the weight of the structural steel was reduced when AISC2005 specification rather than AISC1898 was used in the design. It is therefore concluded that utilizing the new AISC2005 specification is safer in preventingweb buckling because the height of a member is designed to be small despite some differences depending on the structural type.

Minimum-weight design of non-linear steel frames using combinatorial optimization algorithms

  • Hayalioglu, M.S.;Degertekin, S.O.
    • Steel and Composite Structures
    • /
    • v.7 no.3
    • /
    • pp.201-217
    • /
    • 2007
  • Two combinatorial optimization algorithms, tabu search and simulated annealing, are presented for the minimum-weight design of geometrically non-linear steel plane frames. The design algorithms obtain minimum weight frames by selecting suitable sections from a standard set of steel sections such as American Institute of Steel Construction (AISC) wide-flange (W) shapes. Stress constraints of AISC Load and Resistance Factor Design (LRFD) specification, maximum and interstorey drift constraints and size constraints for columns were imposed on frames. The stress constraints of AISC Allowable Stress Design (ASD) were also mounted in the two algorithms. The comparisons between AISC-LRFD and AISC-ASD specifications were also made while tabu search and simulated annealing were used separately. The algorithms were applied to the optimum design of three frame structures. The designs obtained using tabu search were compared to those where simulated annealing was considered. The comparisons showed that the tabu search algorithm yielded better designs with AISC-LRFD code specification.

An Experimental Study on the Axial Stiffness of the Concrete Filled Rectangular Steel Tube Columns (콘크리트충전 각형강관 기둥의 축강성에 관한 실험연구)

  • Cha, Hee-Youn;Song, Hyung-Soo;Min, Chang-Shik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.145-148
    • /
    • 2008
  • AISC-LRFD, ACI 318 and Korean design specifications for concrete filled rectangular steel tube columns do not consider the increasing of axial stiffness such as the elastic modulus and the yield strength due to the confinement effect. AISC-LRFD and ACI 318, however, shows different basic philosophy and equations for computing the elastic modulus and the strength of CFT columns. Through this experimental study, nine rectangular CFT column specimens were made by varying thickness steel tube and concrete strength, the axial stiffness were compared. The comparison between the design specifications and the test results shows different values on the yield strength of the CFT columns. Even though, yield strength of the CFT columns are very similar between AISC-LRFD and Korean design specifications.

  • PDF

A Study of the Modification Factor(B) in the AISC Specification for Elastic Buckling of Web-Tapered Beams (웨브 변단면보의 탄성좌굴에 대한 AISC 기준의 수정계수(B)에 관한 연구)

  • Ryu, Hyo-Jin;Lim, Nam-Hyoung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.2
    • /
    • pp.45-49
    • /
    • 2008
  • This paper investigated the accuracy of the current design formulae for the elastic buckling strength of web-tapered I-beams in AISC-LRFD specification. The basic concept is to replace a tapered beam by an equivalent prismatic beam with a different length, but with a cross section identical to that of the smaller end of the tapered beam. The modification factor, B, is used to account for the stress gradient within the unbraced length and the lateral restraining effects offered by the adjacent segments. The modification factor(B) suggested in AISC-LRFD specification was compared with the finite element method(FEM) results. This paper presented a redefined method to calculate the modification factor(B).

Review of Structural Design Provisions of Rectangular Concrete Filled Tubular Columns (각형 콘크리트충전 강관기둥 부재의 구조설계기준 비교연구)

  • Lee, Cheol Ho;Kang, Ki Yong;Kim, Sung Yong;Koo, Cheol Hoe
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • The structural provisions of rectangular CFT (concrete-filled tubular) columns in the 2005/2010 AISC Specification, ACI 318-08, and EC4 were comparatively analyzed as a preliminary study for establishing the unified standards for composite structures. The provisions analyzed included those related to the nominal strength, the effect of confinement, plate slenderness, effective flexural stiffness, and the material strength limitations. Small or large difference can be found among the provisions of AISC, ACI, and EC4. Generally, the 2010 AISC Specification provides the revised provisions which reflect up-to-date test results and tries to minimize the conflict with the ACI provisions. For example, the 2010 AISC Specification introduced a more finely divided plate slenderness limits for CFT columns. In seismic applications, the plate slenderness limits required for highly and moderately ductile CFT columns were separately defined. However, the upper cap limitations on material strengths in both the AISC and EC4 provisions are too restrictive and need to be relaxed considering the high-strength material test database currently available. This study found that no provisions reviewed in this paper provide a generally satisfactory method for predicting the P-M interaction strength of CFT columns under various material combinations. It is also emphasized that a practical constitutive model, which can reasonably reflect the stress-strain characteristics of confined concrete of rectangular CFT columns, is urgently needed for a reliable prediction of the P-M interaction strength.

Flexural strength of circular concrete-filled tubes

  • Lee, Minsun;Kang, Thomas H.-K.
    • Advances in Computational Design
    • /
    • v.1 no.4
    • /
    • pp.297-313
    • /
    • 2016
  • The flexural strength of circular concrete-filled tubes (CCFT) can be estimated by several codes such as ACI, AISC, and Eurocode 4. In AISC and Eurocode, two methods are recommended, which are the strain compatibility method (SCM) and the plastic stress distribution method (PSDM). The SCM of AISC is almost the same as the SCM of the ACI method, while the SCM of Eurocode is similar to the ACI method. Only the assumption of the compressive stress of concrete is different. The PSDM of Eurocode approach is also similar to the PSDM of AISC, but they have different definitions of material strength. The PSDM of AISC is relatively easier to use, because AISC provides closed-form equations for calculating the flexural strength. However, due to the complexity of calculation of circular shapes, it is quite difficult to determine the flexural strength of CCFT following other methods. Furthermore, all these methods give different estimations. In this study, an effort is made to review and compare the codes to identify their differences. The study also develops a computing program for the flexural strength of circular concrete filled tubes under pure bending that is in accordance with the codes. Finally, the developed computing algorithm, which is programmed in MATLAB, is used to generate design aid graphs for various steel grades and a variety of strengths of steel and concrete. These design aid graphs for CCFT beams can be used as a preliminary design tool.

A Study on Evaluation of Floor Vibration for Steel Frame Modular Housing (철골 조립식주택 바닥판 진동 평가에 관한 연구)

  • Kim, Jong-Sung;Jo, Min-Joo;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.104-111
    • /
    • 2016
  • The steel frame modular housing of which the research and development has been actively carried out recently cannot be constructed through monolithic placement like the reinforced concrete deck of general structure due to the characteristics of construction method of production in the factory and assembly on the site. And floor vertical vibration and deflection caused by inhabitants' activities may become an important issue in the aspect of usability evaluation due to a decrease in the section size of member, a decrease in weight, and so on. Therefore, this study evaluated the vibration performance of deck by using formula of AISC Design Guide 11(hereinafter AISC formula) which was practically used in general for modules where a stud was and wasn't installed at the center of beam in the longitudinal direction in the modular housing to be studied, and examined the applicability of AISC formula through comparison with the results of analysis using a general-purpose analysis program. On the basis of this, a structural cause for an error to occur between analysis result and AISC formula in the deck of module in which a stud was installed was analysed, and measures for considering this were suggested. Besides, an analysis model with the variables of measures for improving the floor vibration performance of modular housing to be studied was established. And measures having excellent vibration performance and economic feasibility were suggested through vibration response analysis and economic evaluation.

Effective Stiffness of Composite Beams Considering Shear Slip Effects (전단슬립 효과를 고려한 합성보의 유효강성)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.671-682
    • /
    • 2004
  • This study investigated the effects of a shear slip on the deflection of steel-concretecomposite beams with partial shear interaction. Under the guidance of various current design codes, this deflection was related to the strength of shear connectors in the composite beams. In this paper, a shear connector stiffness based on exact solutions, regardless of loading conditions, was developed. The equivalent rigidity of composite beams that considered three different loading types was first derived, based on equilibrium and curvature compatibility, from which a general formula accounting for slips was developed. To validate this approach, the predicted maximum deflection under the proposed method was compared against currently used equations to calculate beam effective stiffness (AISC)Nie's equations, which have recently been proposed. For typical beams that were used in practice, shear slips might result in stiffness reduction of up to 18% for short-span beams. For full composite sections, the effective section modulus with the AISC specifications was larger than that of the present study, which meant that the specifications were not conservative. For partial composite sections, the AISC predictions were more conservative than those in the present study.

Systematic Review and Meta-Analysis of Antibiotic-Impregnated Shunt Catheters on Anti-Infective Effect of Hydrocephalus Shunt

  • Zhou, Wen-xiu;Hou, Wen-bo;Zhou, Chao;Yin, Yu-xia;Lu, Shou-tao;Liu, Guang;Fang, Yi;Li, Jian-wen;Wang, Yan;Liu, Ai-hua;Zhang, Hai-jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.297-308
    • /
    • 2021
  • Objective : Shunt infection is a common complication while treating hydrocephalus. The antibiotic-impregnated shunt catheter (AISC) was designed to reduce shunt infection rate. A meta-analysis was conducted to study the effectiveness of AISCs in reduction of shunt infection in terms of age, follow-up time and high-risk patient population. Methods : This study reviewed literature from three databases including PubMed, EMBASE, and Cochrane Library (from 2000 to March 2019). Clinical studies from controlled trials for shunt operation were included in this analysis. A subgroup analysis was performed based on the patient's age, follow-up time and high-risk population. The fixed effect in RevMan 5.3 software (Cochrane Collaboration) was used for this meta-analysis. Results : This study included 19 controlled clinical trials including 10105 operations. The analysis demonstrated that AISC could reduce the infection rate in shunt surgery compared to standard shunt catheter (non-AISC) from 8.13% to 4.09% (odds ratio [OR], 0.48; 95% confidence interval [CI], 0.40-0.58; p=0.01; I2=46%). Subgroup analysis of different age groups showed that AISC had significant antimicrobial effects in all three groups (adult, infant, and adolescent). Follow-up time analysis showed that AISC was effective in preventing early shunt infections (within 6 months after implant). AISC is more effective in high-risk population (OR, 0.24;95% CI, 0.14-0.40; p=0.60; I2=0%) than in general patient population. Conclusion : The results of meta-analysis indicated that AISC is an effective method for reducing shunt infection. We recommend that AISC should be considered for use in infants and high-risk groups. For adult patients, the choice for AISC could be determined based on the treatment cost.