• 제목/요약/키워드: AID Converter

검색결과 50건 처리시간 0.073초

가변주파수에 있어서 유도전동기의 특성도식 산정법에 관해서 제1보 (A Study on the Current-diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency)

  • 박민호
    • 전기의세계
    • /
    • 제17권3호
    • /
    • pp.29-38
    • /
    • 1968
  • The development of the frequency converter using semiconductor enables to easily control the speed of A.C. motors. It is now technically possible and economically feasible to provide them with power at variable frequency, using silicon-controlled-rectifier (or thyristor) inverters. In such a case, if an induction motor is to be operated efficiently over a wide speed range, it must be supplied from a variable-frequency source whose frequency is adjustable over a range similar to that required for the motor speed. It is desired to observe how several characteristics are changed such as primary current, torque-speed, etc. Although the characteristics could be obtained by means of the conventional method, it requires very complicated calculation. It is assumed that the charateristics above are easily investigated by means of current diagram method from variable circuit constants relating to the motor which is designed in rated frequency. In this paper, the results of the study on the current-diagram method and its application are described as follows; (1) In order to discuss the construction of current diagram, the equation of the stator current with adjustable frequency was derived for applying the Current Diagram Method. (2) The radius, the center of the current circle and current vector locus at any desired frequency could be easily determined with the aid of both above mentioned equation and the standard current diagram at reference frequency. (3) This method could be applicable to the various types of Induction Motors, and this paper has dealt with its application to the capacitor, split-phase and 2-phase types of motors.

  • PDF

Embedded Target을 이용한 DC Motor제어가 설계 및 구현 (Design and Implementation for DC Motor controller Using Embedded Target)

  • 신위재
    • 융합신호처리학회논문지
    • /
    • 제13권1호
    • /
    • pp.56-62
    • /
    • 2012
  • 이 논문은 매트랩/시뮬링크에서 도입한 TI 2000 DSP 라이브러리를 위한 임베디드 타켓을 사용하여 직류 모터 시스템에 대한 속도 제어기를 설계하고 구현하였다. 속도 제이기는 매트랩/시뮬링크 프로그램을 사용하여 쉽게 설계하고 구현할 수 있다. 모터 속도의 궤환은 속도 감지기로 엔코드와 펄스미터를 사용하여 eZdsp F2812 의 A/D 변환기를 통하여 처리하였다. 제어기의 실시간 프로그램은 시뮬링크를 사용하여 그렸고, P 제어기, PID 제어기 그리고 매개변수 추정 을 기반 적응제어기의 변환된 프로그램 코드는 Realsys eZdsp 2812 보드로 다운로드하였다. 그리고 실험을 통하여 구현된 제어기들의 속도응답을 확인하였다. 제어대상이 변경되었을 때에도 제어기를 쉽게 설계 및 구현하는 방법을 연구했다.

저전력 3차 델타-시그마 모듈레이터 설계 (Design of Low-Power 3rd-order Delta-Sigma Modulator)

  • 인병화;임새민;박상규
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.43-51
    • /
    • 2013
  • 디지털 보청기에 적합한 저전력 3차 델타-시그마 모듈레이터를 설계하였다. 적분기의 출력 스윙을 최소화 하도록 모듈레이터 구조의 계수를 최적화하고, AB급 출력단을 갖는 2단 연산증폭기와 switched-capacitor 구조를 사용하여 전력소모를 최소화 하였다. 본 모듈레이터는 130nm CMOS 공정을 이용하여 제작되었으며, 샘플링 주파수가 3.2MHz일 때 100Hz-10kHz의 신호대역에서 79dB의 SNR(Signal-to-Noise Ratio)이 측정되었다. 전력소모는 1.2V 전원전압에서 $60{\mu}W$에 불과하며 A/D 변환기 코어의 크기는 $0.53mm{\times}0.53mm$ 이다.

Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석 (QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY)

  • 류명걸;정현주
    • Journal of Periodontal and Implant Science
    • /
    • 제25권1호
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

광전용적맥파 센서를 이용한 맥파전달시간의 측정 (Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor)

  • 최병철;정동근;정도운;노정훈;전계록
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

非定常 熱線法 에 의한 流體 의 熱傳達率 測定 (Measurement of thermal conductivity of fluid by unsteady hot wire method)

  • 고상근;양상식;노승탁
    • 대한기계학회논문집
    • /
    • 제8권2호
    • /
    • pp.154-161
    • /
    • 1984
  • 본 연구에서는 고정밀 아날로그-디지탈 변환기와 마이크로 프로세서(micropr- ocessor) Intel 8085를 사용하여 비정상 아날로그(analog)신호를 왜곡이 없이 디지탈 량으로 직접 변환하여 자료처리하였다. 또한 비정상 열선법은 열선에 전류를 가하여 열선이 열원이며 동시에 온도계의 두 가지 역할을 하므로, 전기전도성이 있는 액체는 적합하지 못한 단점이 있다. 이를 해결하기 위하여 열선에 얇은 절록피복층을 입혀 전기전도성 액체의 열전도율을 측정할 수 있는 가능성에 대한 연구를 시도하였다.

DWT 기반 영상압축 시스템 구현 (Image Compression System Implementation Based on DWT)

  • 서영호;최순영;김동욱
    • 대한전자공학회논문지SP
    • /
    • 제40권5호
    • /
    • pp.332-346
    • /
    • 2003
  • 본 논문에서는 2차원 DWT(Discrete Wavelet Transform)를 이용하여 디지털 영상을 압축 및 복원할 수 있는 시스템을 구현하였다. 제시한 DWT 기반 영상압축 시스템은 크게 영상을 압축하는 FPGA 보드와 영상을 복원하는 응용 소프트웨어로 구성된다. 먼저 영상을 압축하는 FPGA는 A/D 변환기로부터 영상을 받아들여서 웨이블릿 변환을 이용하여 영상을 압축하고 PCI 인터페이스를 이용하여 PC로 저장하며, PC에 저장된 압축된 영상정보는 응용 소프트웨어를 이용하여 복원된다. 영상압축 시스템은 A/D 변환기에 동기하여 NTSC YCbCr(4:2:2)의 640×240 영상을 초당 약 60 필드 압축한다. 구현된 하드웨어는 APEX20KC EP20K1000CB652-7의 FPGA에서 11,120개의 LAB(Logic Array Block)와 27,456개의 ESB(Embedded System Block)를 사용하여 하나의 FPGA내에 사상되었다. 전체적으로 33MHz의 클럭을 사용하고 메모리 제어부는 100MHz의 클럭을 사용하여 동작한다.

광섬유를 이용한 광영상단층촬영기 제작에 관한 연구 (A Study on Optical Coherence Tomography System by Using the Optical Fiber)

  • 양승국;박양하;장원석;오상기;이석정;김기문
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.34-40
    • /
    • 2004
  • 본 연구에서는 인체에 무해하며, 고분해능 측정과 저가격화 및 소형으로 제작이 가능한 광섬유를 이용한 광영상단층촬영기 제작에 관한 것이다. 시스템의 기본원리는 마이켈슨 간섭계를 이용한 것으로서 광섬유를 이용하여 간섭계를 구성하였다. 시스템의 구성으로는 광원은 분해능 및 측정범위를 고려하여 1,300(nm) 중심파장을 가지며 대역폭이 35(nm)인 상용제품의 SLD(Superluminersent diode)를 사용하였으며, 샘플내부의 영상을 검출하기 위한 간섭신호 검출방법은 기준거울이 선형적으로 이동하여 광경로를 일치하는 광지연선로를 구성하였다. 그리고 간섭계는 단일모드 광섬유를 이용하여 마이켈슨 간섭계를 구성하였으며, 스캐너는 시준기를 이용하여 샘플에 대한 초점을 고정하였으며, 스텝모터를 이용하여 샘플에 대한 횡단방향의 이동을 통해 샘플의 2차원 단층영상을 측정하도록 하였다. 수광부는 소신호인 간섭신호를 검출하기 위하여 감도가 뛰어나면 잡음특성이 우수한 800-1,700(nm) 측정범위의 광검출기를 사용하였다. 신호처리부에서 간섭신호의 포락선 신호만을 검출하기 위하여 증폭 및 필터링 하여 A/D 변환을 거친 후 영상검출 프로그램을 통해 실시간으로 단층영상을 나타내도록 하였다. 측정결과 분해능은 약 30($\mu\textrm{m}$)로서 이론식과 일치함을 확인하였으며, 샘플을 이용한 단층촬영에서 실시간으로 양파조직의 조직형태를 측정하였다.

기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템 (Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve)

  • 이혁수
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.421-430
    • /
    • 2004
  • 임상적으로 의사가 청진기를 이용해 초기 혈전이 생긴 기계식 판막 음향신호의 변화를 구분하기는 쉽지 않다. 기계식 판막의 이상은 환자의 죽음을 의미하기 때문에 기계식 판막의 신뢰성과 초기 혈전 현상을 비관혈적으로 조기 진단하는 방법은 매우 중요하다. 이 논문은 컴퓨터 보조진단 시스템과 음향신호의 주파수 스펙트럼의 이동을 관찰하여 기계식 판막의 혈전 현상을 비관혈적으로 평가하는 것을 목적으로 한다. 혈전 모델은 상용화된 기계식 판막에 폴리우레세인과 실리콘을 이용하여 제작하였다. 판막의 표면에는 폴리우레세인을 코팅하고, 봉합링에는 실리콘을 코팅하였다. 봉합링의 주위에서 혈전이 발생하고, 20%, 40%, 60%로 자라나는 현상은 실리콘을 이용하여 제작하였다. 실험 시스템에서 판막의 음향 신호는 마이크로폰과 증폭기를 사용하여 측정하였고, 마이크로폰에는 주위잡음을 제거하기 위해 커플러를 장착하였다. 측정된 음향신호는 A/D 컨버터를 이용하여 샘플링하고, 스펙트럼을 분석하였다. 정상적인 판막과 혈전이 형성된 판막의 주파수 구분을 위해 인공신경망을 구성하였고, 연속적으로 판막의 운동 주기성을 확인하기 위하여 return map을 사용하였다. 생체 내 실험에서는 기계식 판막을 사용하는 순환장치를 장착한 동물과 기계식 판막을 치환 받은 지 1년 이내와 1년이 넘은 환자에게서 데이터를 채집하였다. 실험에서 얻은 데이터 스펙트럼은 두 가지 형태의 첨두치를 보였고, 이중에서 두 번째 첨두치는 혈전의 모델에 따라 변화를 보였다. 생체 내, 외 실험에서 얻은 데이터를 인공신경망에 적용한 결과 정상 판막과 혈전이 생성된 판막을 구분하였고, 환자를 대상으로 한 실험에서는 10명 중 1명이 두 번째 첨두치가 이동하는 결과를 보였지만 다른 방법으로 확인하지는 못했다. 본 논문의 결과는 기계식 판막의 혈전현상을 비침습적으로 조기 진단하고, 상태를 지속적으로 감시할 수 있는 기술적 토대를 제공할 것이다.

Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究) (A Microcomputer-Based Data Acquisition System)

  • 김기대;김상래
    • Journal of Biosystems Engineering
    • /
    • 제7권2호
    • /
    • pp.18-29
    • /
    • 1983
  • 효율적(效率的)인 농업기계(農業機械)의 실내(室內) 및 실외실험(室外實驗)을 위(爲)하여 Microcomputer에 의(依)한 Data 측정(測定)을 위(爲)해 A/D 변환기(變煥器)를 Interface 시키고, 이를 기록보관(記錄保管)하기 위해 Computer memory인 2716용(用) EPROM programmer와 Microprinter를 interface시켰고, 실험(實驗) 후(後)Data를 다시 HP computer로 전송(傳送)하기 위(爲)한 RS232C 장치(裝置) 등(等)의 Hardware를 구성(構成)하고, 이들의 작동(作動)을 위(爲)한 Microprogram을 개발(開發)하여 Data acquisition system으로 활용(活用)할 수 있는 방안(方案)을 연구(硏究)한 본(本) 연구(硏究)의 주요(主要) 결과(結果)를 요약(要約)하면 다음과 같다. 1. 사용(使用) channel수(數), 측정시간(測定時間) 간격(間隔) 및 측정(測定) data수(數)를 자유(自由)로 조정할 수 있는 측정용(測定用) microprogram을 개발(開發)하였으며 최소(最小) 측정시간(測定時間) 간격(間隔)은 $58.8{\mu}s$이었다. 2. A/D 변환기(變煥器)의 Calibration을 위(爲)해 Function generator에서 삼각파(三角波), 구형파(矩形波), sin파등(波等)을 발생(發生)시켜 Oscillograph에서 확인(確認)하고 이를 계측(計測)하여 보관(保管)한 후(後) HP Computer에 전송(傳送)하여 plotting한 결과(結果) 정확(正確)한 파형(波形)을 얻을 수 있었다. 3. Data 기록(紀錄)을 위(爲)한 EPROM programmer는 잘 동작(動作)하였으며 기록(紀錄) 및 원래(原來)의 Data와 비교(比較)하는 데 총 소요시간(所要時間)은 75초 정도였고, 취급이 용이(容易)할 뿐 아니라 지워서 재사용(再使用)할 수 있어 경제적(經濟的)이었다. 4. Data의 기록(記錄)을 위(爲)한 Microprinter는 그 2kB Decimal로 변환(變換)시켜 Print하는 시간(時間)이 15분(分) 정도이었으며 계측(計測)과 동시(同時)에 기록(記錄)시키는 완속측정용(緩速測定用)으로 적당하였다. 5. 본(本) system과 HP3000 컴퓨터 간(間)의 Data 전송(傳送) 장치(裝置)를 사용(使用)하면 2k byte의 Data를 HP3000 computer로 전송(傳送)하는데 1~2분(分)정도 소요(所要)되었고, 작동(作動)은 만족스러웠다. 6. 사용(使用) 전원(電源)은 DC/DC 변환기(變煥器)를 사용(使用)하여 입력전원(入力電源)이 7~25V로 단일화(單一化)하였으며, 그 상용전류(常用電流)는 1.8A정도로 tractor의 battery를 사용(使用)할 경우도 시동시(始動時)에 전압강하(電壓降下)에 의(依)한 컴퓨터의 오동작(誤動作)이 일어나지 않았으며 야외실험(野外實驗)에서의 적응성(適應性)이 우수하였다. 이상(以上)의 결과(結果)를 종합할 때 본(本) system은 실내(室內) 및 실외(室外) 실험(實驗)을 위(爲)한 Data auquistition system으로 활용(活用)할 수 있으며 경제적면(經濟的面)이나 정말 고속 측정(側定) 면(面)에서 우수한 성능(性能)을 갖춘 것으로 인정(認定)된다.

  • PDF