• Title/Summary/Keyword: AF recurrence

Search Result 18, Processing Time 0.022 seconds

Machine Learning Prediction for the Recurrence After Electrical Cardioversion of Patients With Persistent Atrial Fibrillation

  • Soonil Kwon;Eunjung Lee;Hojin Ju;Hyo-Jeong Ahn;So-Ryoung Lee;Eue-Keun Choi;Jangwon Suh;Seil Oh;Wonjong Rhee
    • Korean Circulation Journal
    • /
    • v.53 no.10
    • /
    • pp.677-689
    • /
    • 2023
  • Background and Objectives: There is limited evidence regarding machine-learning prediction for the recurrence of atrial fibrillation (AF) after electrical cardioversion (ECV). This study aimed to predict the recurrence of AF after ECV using machine learning of clinical features and electrocardiograms (ECGs) in persistent AF patients. Methods: We analyzed patients who underwent successful ECV for persistent AF. Machine learning was designed to predict patients with 1-month recurrence. Individual 12-lead ECGs were collected before and after ECV. Various clinical features were collected and trained the extreme gradient boost (XGBoost)-based model. Ten-fold cross-validation was used to evaluate the performance of the model. The performance was compared to the C-statistics of the selected clinical features. Results: Among 718 patients (mean age 63.5±9.3 years, men 78.8%), AF recurred in 435 (60.6%) patients after 1 month. With the XGBoost-based model, the areas under the receiver operating characteristic curves (AUROCs) were 0.57, 0.60, and 0.63 if the model was trained by clinical features, ECGs, and both (the final model), respectively. For the final model, the sensitivity, specificity, and F1-score were 84.7%, 28.2%, and 0.73, respectively. Although the AF duration showed the best predictive performance (AUROC, 0.58) among the clinical features, it was significantly lower than that of the final machine-learning model (p<0.001). Additional training of extended monitoring data of 15-minute single-lead ECG and photoplethysmography in available patients (n=261) did not significantly improve the model's performance. Conclusions: Machine learning showed modest performance in predicting AF recurrence after ECV in persistent AF patients, warranting further validation studies.

Surgical Ablation of Atrial Fibrillation in Patients Undergoing Bioprosthetic Valve Replacement

  • Pyo, WonKyung;Park, Sung Jun;Kim, Wan Kee;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.61-69
    • /
    • 2019
  • Background: Scarce data have been reported on the efficacy of concomitant atrial fibrillation (AF) ablation in patients undergoing bioprosthetic valve replacement. Methods: From 2001 and 2014, 146 consecutive patients ($69.3{\pm}9.4years$, 84 females) who underwent bioprosthetic heart valve replacement concomitant with AF ablation were assessed. We evaluated long-term rhythm and valve-related outcomes. Results: During 49.1 months of follow-up (interquartile range, 22.5-96.8 months), 7 in-hospital and 49 (6.7% per person-year) post-discharge deaths occurred. The thromboembolic event-free survival rate at 5 years was $79.2%{\pm}3.5%$. The freedom from AF recurrence rate at 5 years was $59.8%{\pm}4.9%$. Multivariate analysis showed that old age (hazard ratio [HR], 1.06; 95% confidence interval [CI], 1.02-1.11; p=0.002), previous cardiac operation (HR, 3.01; 95% CI, 1.22-7.43; p=0.02), and a large left atrial (LA) dimension (HR, 1.02; 95% CI, 1.00-1.05; p=0.045) were significantly associated with AF recurrence. Conclusion: The overall long-term clinical outcomes in these predominantly elderly patients undergoing AF ablation concomitantly with bioprosthetic valve replacement were satisfactory; however, AF recurrence was frequent. Older age, a history of prior cardiac surgery, and large LA size were associated with an increased risk of AF recurrence.

Modern Treatment of Atrial Fibrillation

  • Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.47 no.6
    • /
    • pp.499-503
    • /
    • 2014
  • Atrial fibrillation (AF) is the most common type of arrhythmia and has a large global burden. In general, treatment of AF is based on medication and consists of rate and rhythm control together with anticoagulation. However, surgical treatment may be required in patients with AF combined with organic valvular heart diseases or who experience recurrence despite medication. In addition, surgical treatment plays a role in the treatment of lone AF. This article reviews the various surgical treatment options for AF.

Initial Experience with Total Thoracoscopic Ablation

  • Lee, Hee Moon;Chung, Su Ryeun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • v.47 no.1
    • /
    • pp.1-5
    • /
    • 2014
  • Background: Recently, a hybrid surgical-electrophysiological (EP) approach for confirming ablation lines in patients with atrial fibrillation (AF) was suggested. The aim of this approach was to overcome the limitations of current surgery- and catheter-based techniques to yield better outcomes. Methods: Ten consecutive patients with AF underwent total thoracoscopic ablation (TTA) following transvenous catheter EP ablation (residual gap and cavotricuspid isthmus [CTI] ablation). Holter monitoring was performed 6 months postoperatively. Results: Ten patients (90% with persistent AF) underwent successful hybrid procedures, and there was no in-hospital mortality. An EP study was performed in 8 patients and showed that successful antral ablation in all pulmonary veins was achieved in 7 of them. The median follow-up duration was 7.63 months (range, 6.7 to 11.6 months). Nine patients underwent Holter monitoring 6 months postoperatively, and the results indicated an underlying sinus rhythm without AF, atrial flutter, or atrial tachycardia lasting more than 30 seconds in all of the patients. There was no recurrence of AF during follow-up. Conclusion: A hybrid approach that consists of TTA followed by transvenous catheter EP ablation (residual gap and CTI ablation) yielded excellent outcomes in our patient population. A hybrid approach should be considered in patients with a high risk of AF recurrence.

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

Functional Insufficiency of Mitral and Tricuspid Valves Associated With Atrial Fibrillation: Impact of Postoperative Atrial Fibrillation Recurrence on Surgical Outcomes

  • Kitae Kim;Jin Kim;Sung-Ho Jung;JaeWon Lee;Joon Bum Kim
    • Korean Circulation Journal
    • /
    • v.53 no.8
    • /
    • pp.550-562
    • /
    • 2023
  • Background and Objectives: To identify the factors associated with adverse outcomes following surgery for functional insufficiency of the mitral valve (MV) or tricuspid valve (TV) associated with atrial fibrillation (AF). Methods: We evaluated 100 patients (age, 66.5±10.0 years; 47 males) who consecutively underwent surgery for functional insufficiency of the MV or TV associated with AF between January 2000 and December 2020 at our center. The primary outcome was a composite endpoint of all-cause death, valve reoperation, congestive heart failure (CHF) requiring rehospitalization, and stroke. Results: During follow-up (532 patients-years [PYs]), adverse events included death in 16 (3.0%/yr), MV reoperation in 1 (0.2%/yr), CHF in 14 (2.6%/yr), and stroke in 5 (0.9%/yr) patients, demonstrating a 5-year rate of freedom from the primary endpoint of 69.5%. The rate of postoperative AF was high even in those who underwent AF ablation (n=92), with cumulative rates of 48.1% at 1 year and 60.2% at 5 years. In multivariable analyses, the primary outcome was significantly associated with age (adjusted hazard ratio [aHR], 1.06; 95% confidence interval [CI], 1.02-1.10; p=0.005), chronic kidney disease (aHR, 7.76; 95% CI, 2.28-26.38; p=0.001), left atrial appendage exclusion (aHR, 0.35; 95% CI, 0.16-1.78; p=0.010), and postoperative AF as a time-varying covariate (aHR, 3.33; 95% CI, 1.50-7.40; p=0.003). Conclusion: Among patients undergoing surgery for functional atrioventricular insufficiency associated with AF, a significant proportion showed recurrence of AF over time after concomitant AF ablation, which was significantly associated with poor clinical outcomes.

Mid-Term Results of Totally Thoracoscopic Ablation in Patients with Recurrent Atrial Fibrillation after Catheter Ablation

  • Lim, Suk Kyung;Kim, Joo Yeon;On, Young Keun;Jeong, Dong Seop
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.270-276
    • /
    • 2020
  • Background: We investigated the impact of previous catheter ablation (CA) on the midterm outcomes of totally thoracoscopic ablation in patients with lone atrial fibrillation (AF). Methods: Between February 2012 and July 2018, 332 patients underwent totally thoracoscopic ablation for the treatment of AF (persistent AF; n=264, 80%). The patients were stratified into CA (n=47, 14%) and non-CA (nCA; n=285, 86%) groups according to their CA history. Results: All the baseline clinical characteristics and risk factors were similar between the groups except for age, percentage of male patients, prevalence of paroxysmal AF, prior percutaneous coronary intervention, and left atrial volume index (LAVI). No significant intergroup differences were observed in the incidence of early and late complications. At late follow-up, normal sinus rhythm was observed in 92% (43 of 47) of the patients in the CA group and 85% (242 of 285) of the patients in the nCA group (p=0.268). The rate of freedom from AF recurrence at 5 years was 55.3%±11.0% in the CA group, which was similar to that in the nCA group (55.7%±5.1%, p=0.690). In Cox regression analysis, preoperative brain natriuretic peptide levels and LAVI were associated with AF recurrence, but CA history was not significant. Conclusion: Totally thoracoscopic ablation was safe and effective in treating AF irrespective of CA history. A history of CA did not appear to affect the procedural complexity.

2018 심방세동 카테터 절제술 대한민국 진료지침: PART III

  • Lee, Jeong-Myeong;Jeong, Dong-Seop;Yu, Hui-Tae;Park, Hyeong-Seop;Sim, Jae-Min;Kim, Ju-Yeon;Kim, Jun;Yun, Nam-Sik;O, Se-Il;No, Seung-Yeong;Jo, Yeong-Jin;Kim, Ki-Hun
    • International Journal of Arrhythmia
    • /
    • v.19 no.3
    • /
    • pp.285-339
    • /
    • 2018
  • Catheter ablation of atrial fibrillation (AF) is one of the most complex interventional electrophysiological procedures. The success of AF ablation is based in large part on freedom from AF recurrence based on electrocardiography (ECG) monitoring. Arrhythmia monitoring can be performed with the use of noncontinuous or continuous ECG monitoring tools. AF ablation is an invasive procedure that entails risks, most of which are present during the acute procedural period. However, complications can also occur in the weeks or months following ablation. Recognizing common symptoms after AF ablation and distinguishing those that require urgent evaluation and referral to an electrophysiologist is an important part of follow-up after AF ablation. This section reviews the complications associated with catheter ablation procedures performed to treat AF. The types and incidence of complications are presented, their mechanisms are explored, and the optimal approach to prevention and treatment is discussed. Finally, surgical and hybrid AF ablation technology and the indications for concomitant open or closed surgical ablation of AF, stand-alone and hybrid surgical ablation of AF are covered in this section.

Clinical Outcomes of Intracardiac Echocardiography-Guided Contrast Agent-Free Cryoballoon Ablation in Atrial Fibrillation Patients With Renal Insufficiency

  • Dong Geum Shin;Jinhee Ahn;Sang Hyun Park;Sang-Jin Han;Hong Euy Lim
    • Korean Circulation Journal
    • /
    • v.54 no.3
    • /
    • pp.113-123
    • /
    • 2024
  • Background and Objectives: Previous studies have reported an association between impaired renal function and poor outcomes after radiofrequency catheter ablation in patients with atrial fibrillation (AF). However, outcomes of cryoballoon ablation (CBA) in patients with renal insufficiency are not fully elucidated. This study aimed to compare outcomes of CBA in AF patients with chronic kidney disease (CKD) versus those without CKD and to assess changes in renal function over 12 months following CBA. Methods: A total of 839 patients (65.1% with non-paroxysmal AF [PAF]) who underwent de novo CBA were prospectively enrolled. We divided patients into two groups based on creatinine clearance rate (CCr) and performed intracardiac echocardiography (ICE)-guided contrast agent-free CBA. Results: In comparison with patients without CKD (CCr >50, n=722), those with CKD (CCr ≤50, n=117) were older and predominantly female, had a lower body mass index, and showed a higher prevalence of heart failure and hypertension. Mean CHA2DS2-VAS score was significantly higher in CKD group than in non-CKD group. Procedure-related complications were not significantly different between two groups. During a mean follow-up period of 25.4±11.9 months, clinical recurrence occurred in 182 patients (21.7%) and not significantly different between two groups. In multivariate analysis, non-PAF and left atrial size were independent predictors of AF recurrence. CCr levels significantly improved over 12 months after CBA in CKD group. Conclusions: ICE-guided contrast-agent-free CBA showed comparable long-term clinical outcomes without increasing procedure-related complications and improvement of renal function over 12 months following CBA in AF patients with CKD.

The Effects of Radiofrequency Catheter Ablation for Atrial Fibrillation on Right Ventricular Function

  • Minkwan Kim;Jae-Sun Uhm;Je-Wook Park;SungA Bae;In Hyun Jung;Seok-Jae Heo;Daehoon Kim;Hee Tae Yu;Tae-Hoon Kim;Boyoung Joung;Moon-Hyoung Lee
    • Korean Circulation Journal
    • /
    • v.54 no.4
    • /
    • pp.203-217
    • /
    • 2024
  • Background and Objective: The effects of radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) on right ventricular (RV) function are not well known. Methods: Patients who underwent RFCA for AF and underwent pre- and post-procedural echocardiography were enrolled consecutively. Fractional area change (FAC), RV free-wall longitudinal strain (RVFWSL), and RV 4-chamber strain including the ventricular septum (RV4CSL) were measured. Changes in FAC, RVFWSL, and RV4CSL before and after RFCA were compared among paroxysmal AF (PAF), persistent AF (PeAF), and long-standing persistent AF (LSPeAF) groups. Results: A total of 164 participants (74 PAF, 47 PeAF, and 43 LSPeAF; age, 60.8 ± 9.8 years; men, 74.4%) was enrolled. The patients with PeAF and LSPeAF had worse RV4CSL (p<0.001) and RVFWSL (p<0.001) than those with PAF and reference values. Improvements in RVFWSL and RV4CSL after RFCA were significant in the PeAF group compared with the PAF and LSPeAF groups (ΔRV4CSL, 8.4% [5.1, 11.6] in PeAF vs. 1.0% [-1.0, 4.1] in PAF, 1.9% [-0.2, 4.4] in LSPeAF, p<0.001; ΔRVFWSL, 9.0% [6.9, 11.5] in PeAF vs. 0.9% [-1.4, 4.9] in PAF, 1.0% [-1.0, 3.6] in LSPeAF, p<0.001). In patients without recurrence, improvements in RVFWSL and RV4CSL after RFCA were significant in the PeAF group compared to the LSPeAF group. Conclusions: RV systolic function is more impaired in patients with PeAF and LSPeAF than in those with PAF. RV systolic function is more improved after RFCA in patients with PeAF than in those with PAF or LSPeAF.