• Title/Summary/Keyword: AC sensitivity

Search Result 109, Processing Time 0.04 seconds

Optimal Array Design of the Permanent Magnet in an Eddy Current Brake (와전류 브레이크의 영구자석배열 최적설계)

  • Choi, Jae-Seok;Yoo, Jeong-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.7
    • /
    • pp.658-663
    • /
    • 2009
  • Eddy current is usually generated in the material with high conductivity by time-varying source such as AC current and also is induced by the moving source with relative velocity. The contactless magnetic brake makes use of the braking force from the eddy current generated by the moving source and currently used for the secondary brakes of heavy trucks, buses and rail vehicles. This study aims to design the magnetization pattern of the eddy current brake system of a permanent magnet type where the design aim is to maximize the braking force. The analysis of brake systems is based on the two-dimensional finite element analysis. We use the sequential linear programming as the optimizer and the adjoint variable method is applied for the sensitivity analysis.

Design of an Electrodynamic Wheel for Transfer of Conductive Rod (전도성 환봉 이송용 동전기 차륜의 설계)

  • Park, Sung-Jun;Jung, Kwang-Suk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.251-256
    • /
    • 2011
  • Instead of multi-phase ac current, the magnetic field travels spatially through mechanical rotation of permanent magnets at the electrodynamic wheel (EDW). Traveling of magnetic field generally leads to a generation of inductive force in the traveling direction. In this paper, we suggest a spiral EDW to travel the magnetic field in the axial direction of the conductive rod. So, it is possible to levitate and transfer the rod through multi-axial forces by the spiral EDW. However, physical dimensions of permanent magnets constituting EDW influence relative ratios between three-axial forces generated on the rod. Therefore, the sensitivity analysis for design parameters is performed using FEM analysis. The stable operation is verified experimentally.

A New Algorithm for Contingency Analysis (새로운 상정사고 해석 알고리)

  • 박영문;김재철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.6
    • /
    • pp.232-240
    • /
    • 1984
  • This paper presents a new algorithm for power system contingency analysis and sensitivity matrix associated with the contingency measures. The algorithm has several advantages over conventional ones in terms of both accuracy and time of computation by improving base A.C. load flow calculation scheme, contingency evaluaiton formula based on a variable slack generating power concept and transmission loss formula. The algorithm was tested for the 5-bus system and 24-bus IEEE Reliability Test system with satisfactory results.

  • PDF

Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch (가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전 측정)

  • Choi, Su-Yeon;Park, Chan-Yong;Park, Dae-Won;Kim, Il-Kwon;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.476-477
    • /
    • 2007
  • This paper described the partial discharge (PD) measurement techniques for diagnosing gas-insulated switches in overhead power distribution system. A capacitive voltage probe to detect PD pulse was designed and fixed on the surface of a bushing. We also designed a coupling network to attenuate AC voltage by 270 dB, and a low-noise amplifier having the gain of 40 dB and 500 kHz~20 MHz 3 dB. From the calibration, it was calculated that the sensitivity of the measurement system was 0.94mV/pC. In the application experiment, we could measure a PD pulse of 45 pC.

  • PDF

Identification of a Cupin Protein Gene Responsible for Pathogenicity, Phage Susceptibility and LPS Synthesis of Acidovorax citrulli

  • Rahimi-Midani, Aryan;Kim, Min-Jung;Choi, Tae-Jin
    • The Plant Pathology Journal
    • /
    • v.37 no.6
    • /
    • pp.555-565
    • /
    • 2021
  • Bacteriophages infecting Acidovorax citrulli, the causal agent of bacterial fruit blotch, have been proven to be effective for the prevention and control of this disease. However, the occurrence of bacteriophage-resistant bacteria is one of hurdles in phage biocontrol and the understanding of phage resistance in this bacterium is an essential step. In this study, we aim to investigate possible phage resistance of A. citrulli and relationship between phage resistance and pathogenicity, and to isolate and characterize the genes involved in these phenomena. A phage-resistant and less-virulent mutant named as AC-17-G1 was isolated among 3,264 A. citrulli Tn5 mutants through serial spot assays and plaque assays followed by pathogenicity test using seed coating method. The mutant has the integrated Tn5 in the middle of a cupin protein gene. This mutant recovered its pathogenicity and phage sensitivity by complementation with corresponding wild-type gene. Site-directed mutation of this gene from wild-type by CRISPR/Cas9 system resulted in the loss of pathogenicity and acquisition of phage resistance. The growth of AC-17-G1 in King's B medium was much less than the wild-type, but the growth turned into normal in the medium supplemented with D-mannose 6-phosphate or D-fructose 6-phosphate indicating the cupin protein functions as a phosphomannos isomerase. Sodium dodecyl sulfa analysis of lipopolysaccharide (LPS) extracted from the mutant was smaller than that from wild-type. All these data suggest that the cupin protein is a phosphomannos isomerase involved in LPS synthesis, and LPS is an important determinant of pathogenicity and phage susceptibility of A. citrulli.

Transparent and Flexible All-Organic Multi-Functional Sensing Devices Based on Field-effect Transistor Structure

  • Trung, Tran Quang;Tien, Nguyen Thanh;Seol, Young-Gug;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.491-491
    • /
    • 2011
  • Transparent and flexible electronic devices that are light-weight, unbreakable, low power consumption, optically transparent, and mechanical flexible possibly have great potential in new applications of digital gadgets. Potential applications include transparent displays, heads-up display, sensor, and artificial skin. Recent reports on transparent and flexible field-effect transistors (tf-FETs) have focused on improving mechanical properties, optical transmittance, and performances. Most of tf-FET devices were fabricated with transparent oxide semiconductors which mechanical flexibility is limited. And, there have been no reports of transparent and flexible all-organic tf-FETs fabricated with organic semiconductor channel, gate dielectric, gate electrode, source/drain electrode, and encapsulation for sensor applications. We present the first demonstration of transparent, flexible all-organic sensor based on multifunctional organic FETs with organic semiconductor channel, gate dielectric, and electrodes having a capability of sensing infrared (IR) radiation and mechanical strain. The key component of our device design is to integrate the poly(vinylidene fluoride-triflouroethylene) (P(VDF-TrFE) co-polymer directly into transparent and flexible OFETs as a multi-functional dielectric layer, which has both piezoelectric and pyroelectric properties. The P(VDF-TrFE) co-polumer gate dielectric has a high sensitivity to the wavelength regime over 800 nm. In particular, wavelength variations of P(VDF-TrFE) molecules coincide with wavelength range of IR radiation from human body (7000 nm ~14000 nm) so that the devices are highly sensitive with IR radiation of human body. Devices were examined by measuring IR light response at different powers. After that, we continued to measure IR response under various bending radius. AC (alternating current) gate biasing method was used to separate the response of direct pyroelectric gate dielectric and other electrical parameters such as mobility, capacitance, and contact resistance. Experiment results demonstrate that the tf-OTFT with high sensitivity to IR radiation can be applied for IR sensors.

  • PDF

A STUDY ON THE RADIOPACITY OF GLASS IONOMER CEMENTS (Glass Ionomer Cement의 방사선 불투과성에 관한 연구)

  • Park, Soo-Kyeong;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.122-132
    • /
    • 1993
  • The aim of this study was to investigate the level of radiopacity of glass ionomer cements and to determine the optimum level of radiopacity that is the most compatible with the radiographic diagnosis of secondary caries. The experiments were performed in two parts. In the first part, the radiopacities of 9 glass ionomer cements (FI, FII, FI-LC, FII-LC, SI, SII, Vit, B-VLC, AC) and base materials(Ultra-Blend, Zinc phoaphate cements, Cavitec, Dycal) were measured by densitometer. Then all experimental materials were divided into 5 groups based on the level of radiopacity of enamel and dentin. In the second part, class III cavities with or without secondary caries were prepared in extracted anterior teeth. The representative materials of each group with different radiopacities were inserted into each cavity. The radiographs were interpreted by 15 dentists and seconsary caries were diagnosed according to a five-point confidence rating. Sensitivity and ROC analysis were used to compare observer performance. The following results were obtained : 1. The radipacity of glass ionomer cements varied between 1.111mm Al and 6.011mm Al equivalent. 2. Among experimental materials, three materials in group I had lower radiopacity than that of dentin. The radiopacity of two materials in group II slightly exeeded that of dentin. Three materials in group III had slightly lower radiopacity than that on enamel. The radiopacity of one material in group W was slightly higher than that of enamel. Four materals in group V had the radiopacity that exeeded over 2.0mm AI equivalent to that of enamel. 3. The group IV was the highest for sensitivity and the group V was the highest for ROC area. However, no significant differences were obtained among group II, III, IV and V (P<0.05) but only group I was significantly lower(P<0.01). 4. In comparison with the observer performance for the radiographic diagnosis of secondary caries, the group II, III, IV, and V were superior to the group I (P<0.01). And so the optimum level of radiopacity to detect the secondary caries was the radiopacity that is higher than that of dentin.

  • PDF

A Study on the Weighing scales Design for Electrical Activity Monitoring of the Heart (심장의 전기활동 측정이 가능한 체중계 설계에 관한 연구)

  • Lee, Kang-Hwi;Kang, Seung-Jin;Kim, Kyung-Nam;Min, Se-Dong;Choi, Dong-Hak;Lee, Jeong-Whan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1822-1825
    • /
    • 2015
  • 본 논문에서는 운동 전후 또는 심장 질환과 관련 있는 사용자가 체중을 측정하면서 동시에 심전도 신호를 측정하여 운동 부하에 따른 심장의 활동 상태를 모니터링 할 수 있는 장치를 고안하였다. 이를 위한 방법으로 체중계에 수정된 바이폴라 금속전극을 적용하여 표준사지 측정법을 이용하여 심장활동 신호를 측정할 수 있는 방법을 제안하였다. 체중계에서 심전도를 측정하기 위해 기존의 Ag-AgCl 전극이 아닌 금속 판 형태의 전극을 사용하였으며 이를 위해 입력 임피던스의 설계를 브릿지 형의 AC-Coupling 회로를 통해 높은 CMRR이 유지되도록 설계하였다. 또한 시시각각 변화하는 노이즈를 제거하기 위해 Savitzky-golay filter를 사용하였으며 이를 통해 Baseline wandering 이 제거된 최종 심장활동 신호를 획득하였다. R-peak 검출을 통해 기준신호와의 심박수 및 Sensitivity의 비교평가를 수행하여 이 장치의 성능을 평가한 결과 심박 검출률의 평균 Sensitivity가 97.1%로 나타났다. 동잡음 제거에 대한 알고리즘이 보다 최적화 되어 최종 출력 신호의 안정성이 향상 된다면 체중계를 통한 심박 검출의 가능성과 그 유효성이 충분할 것으로 사료된다.

Development of Prevotella nigrescens ATCC $33563^T$-Specific PCR Primers (Prevotella nigrescens ATCC $33563^T$ 균주-특이 중합효소연쇄반응 프라이머 개발)

  • Song, Soo-Keun;Yoo, So-Young;Kim, Mi-Kwang;Kim, Hwa-Sook;Lim, Sun-A;Kim, Do-Kyung;Park, Jae-Yoon;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.212-220
    • /
    • 2008
  • A Pn10 DNA probe was introduced as a Prevotella nigrescens ATCC $33563^T$-specific DNA probe. In that study, the specificity of the Pn10 was tested with only type or reference strains of 5 oral bacterial species. The purpose of this study is to evaluate the specificity of the Pn10 using the wild type strains of P. nigrescens and is to develop the P. nigrescens ATCC $33563^T$-specific PCR primers based on the nucleotide sequence of the Pn10. The specificity of the Pn10 DNA probe was determined by Southern blot analysis. The nucleotide sequence of Pn10 DNA probes was determined by chain termination method. The PCR primers were designed based on the nucleotide sequence of cloned DNA fragment. The data showed that Pn10 DNA probe were hybridized with the genomic DNAs from P. nigrescens ATCC $33563^T$ and KB6. The Pn10 homologous region, KB6-Pn10, of P. nigrescens KB6 was cloned by PCR and sequenced. The Pn10 and KB6-Pn10 DNA fragments were consisted of 1,875 bp and 1,873 bp, respectively. The percent identity of the two was 98.8% and the divergence of them was 0.6%. The two primer sets (Pn10-F-AC/ Pn10-R-AC and Pn10-F-A/ Pn10-R-A), designed base on the nucleotide sequences of Pn10 DNA probe, were specific to the P. nigrescens ATCC $33563^T$. The two PCR primer sets could detect as little as 4 pg of genomic DNA of P. nigrescens ATCC $33563^T$. These results indicate that the two PCR primer sets have proven useful for the identification of P. nigrescens ATCC $33563^T$, especially with regard to the maintenance of the strain.

광원의 색측정에 대한 IES 지침 해설

  • 이진우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.4
    • /
    • pp.8-14
    • /
    • 1991
  • In this paper, the variable speed control of permanent magnet synchronous motor driven by a sinusoidal PWM inverter based on maximun torque sensitivity is presented. The developed torque or speed control is achieved by the field orientation technique. For the field orientation, the resolver is used as the rotor positioning sensor mounted on the motor shaft without pull-out of the synchonism at any speed. To show the validity of proposed control method, the simulation and experimental results are provided. The advantages of the proposed control method are to achieve the fast current and speed responses.

  • PDF