• Title/Summary/Keyword: AC loss measurement

Search Result 51, Processing Time 0.021 seconds

AC Loss Characteristics of a Single-layered Cylindrical High Temperature Superconductor (단층원통형 고온초전도도체의 교류손실 특성)

  • Ma, Yong-Hu;Li, Zhu-Yong;Ryu, Kyung-Woo;Sohn, Song-Ho;Hwang, Si-Dol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.626-630
    • /
    • 2007
  • The AC loss is an important issue in the design of the high temperature superconductor (HTS) power cables and fault current limiters. In these applications, a cylindrical HTS conductor is often used. In commercialization of these apparatuses, AC loss is a critical factor but not elucidated completely because of complexities in its measurement, e.g. non-uniform current distribution and phase difference between currents flowing in an individual HTS tape. We have prepared two cylindrical conductors composed of a Bi-2223 tape with different critical current density. In this paper, the AC loss characteristics of the conductors have been experimentally investigated and numerically analyzed. The result show that the measured losses for two conductors are not dependent on both arrangements and contact positions of a voltage lead. This implies that most of loss flux is only in the conductors. The loss for the Bi-2223 conductor with low critical current density is in good agreement with the calculated loss from Monoblock model, whereas the loss measured for the Bi-2223 conductor with high critical current density doesn't coincide with the loss calculated from the Monoblock model. The measured loss is also different from numerically calculated one based on the polygon model especially in low transport current.

AC loss dependency on the arrangement of the HTS wires in the current limiting module for SFCL (초전도 한류모듈 내 고온초전도 선재 배치에 따른 교류손실 변화)

  • Kim, W.S.;Yang, S.E.;Lee, J.Y.;Kim, H.;Yu, S.D.;Hyun, O.B.;Kim, H.R.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.9-12
    • /
    • 2012
  • Usually, the AC loss from the superconducting element of an SFCL due to the load current is very small because it is composed of the combination of bifilar windings with very small reactance. Although the AC loss is small enough, we should be albe to predict for the design and control of the cryogenic system. In fact, an SFCL for the transmission voltage class may not generate ignorable AC loss because of the inevitable space between the HTS wires for the high voltage insulation and cryogenic efficiency. To measure the AC loss dependency on the space between the 2G HTS wires with the width of 4.4 mm, we prepared an experimental setup which could adjust the distance between the wires. We used two 500-mm length HTS wires in parallel and applied the current in the opposite direction for each wire to simulate a part of a current limiting module for a high voltage SFCL. We also put two couples of voltage taps at the ends of each wire and a cancel coil in the voltage measurement circuit to compensate the reactive component from the voltage taps. In this condition, we varied the distance between the wires to investigate the change of the transport current loss. A similar experimental study with HTS wire with the width of 12 mm is now in progress.

Measurement of the Magnetization Loss in a HTS Tape (고온초전도선재의 자화손실 측정)

  • Sim, Jeong-Uk;Lee, Hui-Jun;Cha, Gwi-Su;Lee, Ji-Gwang;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.4
    • /
    • pp.182-186
    • /
    • 1999
  • Evaluation of the AC losses in the HTS tapes which are used in electric power machines in one of the important topics in this field. This paper deals with the calculation and measurement of the magnetization loss in HTS tapes. Bean model is adopted for the theoretical calculation of the magnetization loss. Magnetization method is used for the measurement of the loss. Two types of the HTS tape model, multi-filamentary model and mono-filamentary model, are used to evaluate the magnetization loss in this paper. According to the results of the analysis, large discrepancy between the calculated and measured value is observed in multi-filamentary model is more useful than multi-filamentary model for the evaluation of the magnetization loss.

  • PDF

Experimental study on the correlation between measurement length and winding or twist pitch for magnetization loss occurring in CORC and TSTC

  • Ji-Kwang Lee;Jinwoo Han;Kyeongdal Choi;Woo-Seok Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.40-44
    • /
    • 2023
  • For high-temperature superconducting power applications that need large current capacity, a large current conductor manufactured using multiple superconducting tape is required. Conductors being studied for large currents capacity such as CORC, TSTC, and RACC have advantages and disadvantages, and in order to use these conductors in coil form and apply them to AC power devices, research on magnetization loss occurring in superconductors due to external magnetic fields is essential. To accurately measure magnetization loss in a conductor that is twisted by stacking straight conductors like TSTC, the correlation between the measuring system and the shape of the sample must be clearly known to accurately measure the loss. In this paper, we will confirm the difference in magnetization loss measurement values according to the correlation between the length of the pickup coil and the twist pitch of the sample in CORC and TSTC shapes, and review considerations for accurate magnetization loss measurement from the results.

AC Loss Test Setup Development of a Single Bi-2223 Tape (Bi-2223 테이프의 교류손실 평가장치 개발)

  • 김현준;류경우;최병주;황시돌
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.3-6
    • /
    • 2003
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed, To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that test data from the developed setup well agree with losses measured at different institutes.

  • PDF

Measurement and Numerical Analysis of AC Loss in the HTS Pancake Coil and the HTS Solenid Coil (고온초전도 팬케이크 코일과 솔레노이드 코일의 교류손실 측정 및 수치해석)

  • Park Myung-Jin;Lee Sang-Soo;Lee Seung-Wook;Cha Guee-Soo;Lee Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.732-738
    • /
    • 2004
  • In this paper, we constructed 13 turns pancake coil and solenoid coil with HTS tape and measured AC losses of the pancake coil. The critical current of the pancake coil and the solenoid coil were 80A and 109A, respectively. To compare measured AC losses of the two coils, we carried out numerical analysis using 2-D FEM program for manufactured coils. This paper presents current density distribution, flux density distribution and AC losses of the pancake coil and the solenoid. As a result, we obtained that current density distribution was closely related to the orientation of magnetic field and distribution of AC losses were also closely related to the perpendicular component of flux density distribution in coil. The calculated AC losses of the two coils showed good agreement with measured AC losses and AC losses of the pancake coil was about 9 times bigger than that of the solenoid coil under the same turns and length.

An Analysis on Core Loss Characteristics for Permanent Magnet Synchronous Generator considering the Load Conditions (부하조건을 고려한 영구자석형 동기발전기의 철손 특성 해석)

  • Jang, Seok-Myeong;Ko, Kyoung-Jin;Kim, Hyun-Kyu;Lee, Sung-Ho;Sung, Tae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.55-57
    • /
    • 2009
  • This paper deals with an improved core loss calculation under the load conditions, namely, no-load, AC-load and DC-load of multi-pole PM generator from curve fitting method using modified Steinmetz equation considered anomalous loss. For an accurate calculation, magnetic field analyses in stator core considering the time harmonics are performed. And using the nonlinear finite element analysis (FEA), we applied separated rotating and alternating magnetic field to core loss calculation. In order to verify the core loss results by proposed method, the experimental system for no-load core loss measurement has been implemented with DC motor, power analyzer and manufactured PM generator. And, the analysis results with rotational speed agree extremely well with those obtained by measurement.

  • PDF

Measurement of magnetization loss according to the winding pitch of CORC®

  • Han, Jinwoo;Choi, Kyeongdal;Kim, Woo-Seok;Lee, Ji-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.4
    • /
    • pp.25-29
    • /
    • 2021
  • For the application of HTS wire to AC power equipment, a conductor with high current capacity and low loss is required. CORC®, one of the high-current conductors manufactured using several HTS wires, is made by winding the wires in a spiral on a cylindrical former. Because the magnetization loss of a CORC® conductor depends on the degree of magnetic coupling between the wires constituting the CORC®, it is necessary to know the value of the magnetization loss of the CORC® itself. In order to obtain an accurate loss value, it is necessary to know the effect of the ratio of the winding pitch of the CORC® conductor in the pickup coil region sampling the magnetization loss signal. To confirm this effect, we prepare CORC® samples having various winding pitches, and measure and compare the magnetization losses. In addition, the magnetization loss was measured while rotating the CORC® samples and it was examined whether there was a difference in the magnetization loss according to the rotation.

Measurement of Grain Moisture Content using RF Impedance (I) - Electrical Properties of Grain - (고주파 임피던스를 이용한 곡류의 함수율 측정에 관한 연구 (I) - 곡류의 전기적 특성 구명 -)

  • 김기복;노상하
    • Journal of Biosystems Engineering
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 1999
  • The electrical properties such as dielectric constant, dielectric loss factor and AC conductivity of grain were presented to measure the moisture content of grain using RF impedance. At frequency ranging from 1 to 10MHz and room temperature, $20^{\circ}C$, vector network analyzer(HP4195) and coaxial type sample holder were used to analyze the electrical properties of paddy(11∼24%w.b.), brown rice(11∼18%w.b.), barley(11∼21%w.b.) and wheat(11∼23%w.b.) depending on the moisture content, frequency and bulk density. The dielectric constant and AC conductivity of grain samples increased with moisture content and bulk density. The dielectric constants decreased with frequency and could be expressed as function of the moisture density(decimal moisture $content{\times}bulk$ density).

  • PDF

Characteristic of Transport Current loss case of composition multi stacked with BSCCO wire and YBCO wire (1세대 선재와 2세대 선재의 혼합 적층시 발생하는 전송전류 손실 특성)

  • Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Ji-Kwang;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.845-846
    • /
    • 2006
  • Reduce AC loss is very important in superconductor power machine. And HTS power application are needed an increment of current capacity. in this paper estimate AC loss effect and increase of current according tocomposition stack with 1G wire and 2G wire by measurement. A Method of composition stack are YBCO-BSCCO, YBCO-BSCCO-BSCCO-YBCO and BSCCO-YBCO-YBCO-BSCCO. also, test result compared analytic equation by Norries

  • PDF