• 제목/요약/키워드: AC loss characteristics

검색결과 162건 처리시간 0.025초

A Review on AC Loss Characteristics of High $T_c$ Superconductors

  • Amemiya, N.;Jiang, Z.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2006
  • This paper reviews AC loss characteristics of high $T_c$ superconductors. The mechanisms of AC loss generation are explained briefly, and AC losses are classified by the magnetic field components which generate them. A couple of analytical formulae of AC losses, which are useful for simple and rough AC loss estimations, are presented. AC loss characteristics of single BSCCO multifilamentary conductors and single YBCO coated conductors are reviewed based on previous experimental and numerical studies. AC loss characteristics of those two types of practical high $T_c$ superconductors are compared with each other.

Total AC Loss by simultaneously applied AC transport current and AC external magnetic field in BSCCO Tape

  • Park Myungjin;Lim Hyoungwoo;Cha Gueesoo;Lee Jikwang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권4호
    • /
    • pp.10-13
    • /
    • 2005
  • Transport current and magnetic field which is generated by transport current make AC current - AC mag-netic field condition(AC-AC condition) in AC power application system using HTS tape. Therefore, characteristics of AC loss under the AC-AC condition are necessary to estimate AC loss of power device with accuracy such as HTS transformer. In this paper, we researched transport current loss, magnetization loss by perpendicular magnetic field and total loss which is represented as summation of both losses under the AC-AC condition in single HTS tape. As a result, magnetization loss showed increasing behavior under 65mT and decreasing behavior upper 65mT by influence of transport current. Transport current loss was increased continuously through out whole measurement ranges in the AC-AC condition. Total loss in HTS tape was dominated entirely by magnetization loss.

고온초전도 적층선재의 특성과 적층선재로 제작한 팬케이크 권선 손실 (Characteristics of the HTS Stacked Tapes and AC Losses of the Multi-Stacked Pancake Coil)

  • 이승욱;임형우;차귀수;이지광
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.658-663
    • /
    • 2004
  • According to the improvement of the HTS wires performance, several tapes of HTS superconducting machines are being developed. Stacked HTS tapes are used as conductor that can flow high current for the HTS power machines. To develop the HTS power machines, the critical current characteristics of a stacked HTS tapes in external filed and AC losses should be examined. In this paper, we present characteristic of the stacked HTS tapes and AC losses of HTS pancake windings with stacked tapes. AC loss of the pancake winding were measured and compared with the calculated loss by using AC loss data of the stacked samples and the magnetic flux density in the HTS winding under operating conditions. We can see that measured results generally agree well with the calculated results by using AC loss data of 4-stacked sample.

전류분포가 3본-도체의 임계전류/교류손실 특성에 미치는 영향 (Influence of Current Distributions on Critical Current and AC Loss Characteristics in a 3-conductor)

  • 류경우;최병주
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.418-423
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$\sub$c/ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The critical current and AC loss characteristics in the conductor have experimentally investigated. The results show that for uniform current distributions the conductor's critical current is proportional to the critical current of the Bi-2223 tape to which a voltage lead is attached. However it depends on the current non-uniformity parameter in the conductor rather than the tape's critical currents for nonuniform current distributions. The loss tests indicate that the AC loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.

도체의 배열 및 전류방향이 코일형 한류소자의 교류손실 특성에 미치는 영향 (Effect of Conductor's Arrangement and Current Direction on AC Loss Characteristics of a Fault Current Limiting Coil)

  • 마용호;류경우;박권배;오일성
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.17-20
    • /
    • 2005
  • AC loss of a high $T_c$ superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in the power systems. Therefore, several samples of the fault current limiting coils have been fabricated and the effect of conductor's arrangement and current direction on AC loss characteristics investigated experimentally The test result shows that the AC losses measured in the fault current limiting coils depend significantly on the conductor's arrangement. Futhermore, they are also considerably influenced by the conductor's current direction. The AC loss measured in the face-to-face arrangement is smallest among the fault current limiting coil samples.

고온 초전도 tape의 임계전류 저하에 따른 교류손실 특성 (AC loss Characteristics under Critical Current Degradation of HTS Tapes)

  • 김해준;조전욱;김재호;심기덕;곽동순;배준한;김해종;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권3호
    • /
    • pp.29-33
    • /
    • 2005
  • Critical current$(I_c)$ degradation of High $T_c$ Superconducting(HTS) tapes and AC loss under mechanical load is one of the hottest issues in HTS development and application. Mechanical load reduces the critical current of superconducting wire, and the $I_c$ degradation affects the AC loss of the wire. We measured the $I_c$ degradation and AC loss under tension and bending of Bi-2223 tapes made by 'Powder-in-Tube' technique at 77K with self-field. Also, we have studied the frequency characteristics on self-field AC loss in multi-filamentary Bi-2223/Ag tape at 77K. The measurement results and discussions on the relationship between $I_c$ degradation and AC loss are presented.

코일형 한류소자의 교류손실 특성 (AC Loss Characteristic in the Fault Current Limiting Elements of a Coil Type)

  • 류경우;마용호
    • 한국전기전자재료학회논문지
    • /
    • 제18권4호
    • /
    • pp.370-374
    • /
    • 2005
  • AC loss of a superconducting conductor has a strong influence on the economic viability of a superconducting fault current limiter, which offers an attractive means to limit short circuit current in power systems. Therefore, the AC loss characteristics in several fault current limiting elements of a coil type have been investigated experimentally. The test result shows that AC losses measured in the fault current limiting elements depend on arrangement of a voltage lead. The AC loss of a bifilar coil is smallest among the fault current limiting elements of the coil type. The measured AC loss of the bifilar coil is much smaller than that calculated from Norris's elliptical model. However, the loss measured in a meander, which is frequently used in a resistive fault current limiter, agrees well to the theoretical one.

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.206-209
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

전류분포가 3본-도체의 교류손실 특성에 미치는 영향 (Influence of Current Distributions on AC Loss Characteristics in a 3-conductor)

  • 정재훈;류경우
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.7-10
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

테이프 배열이 3본-도체의 교류손실 특성에 미치는 영향 (Influence of tape′s arrangements on AC Loss Characteristics in a 3-conductor)

  • 조영호;허대행;류경우;최병주;황시돌
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.260-262
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$, superconducting power cables which consist of a number of Bi-2223 tapes wound on a cylindrical former. In this paper, the ac loss characteristics in the 3-conductor have investigated experimentally. The loss test results indicate that the ac loss is not related to the arrangement of Bi-2223 tapes, contact position and applied frequency. The measured losses in face-to-face arrangement are larger than those in edge-to-edge arrangement. The measured losses in the 3-conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF